Finden Sie schnell testem für Ihr Unternehmen: 252 Ergebnisse

TD 5000 Tan delta test set

TD 5000 Tan delta test set

The high-voltage generator TD 5000 is a complementary module of STS serie. TD 5000 designed to perform Tan Delta measurements, dissipation factor and capacitance of transformer and bushing at the frequency of the mains or in a wide frequency range. Main features Optional module for STS 5000 and STS 4000 test set, standard module for STS 3000 light Tan Delta, capacitance, dissipation factor measurements and for exciting current test Output voltage from 12 V up to 12 kV Variable output frequency: 1 – 500 Hz PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report Compact and lightweight Patented technology Tests performed Tangent Delta Capacitance Dissipation factor
Pull Tester PS 27 Auszugstester

Pull Tester PS 27 Auszugstester

Der PullTester 27 ist ein motorgetriebenes Zwei-Bereich-Tisch-Messgerät zur Ermittlung der Abzugskraftwerte von Crimpverbindungen, verschweißten Verbindungen oder von vielen anderen Möglichkeiten. PullTester 27 Abzugskraft-Messgerät Übersicht Der PullTester 27 ist ein motorgetriebenes Zwei-Bereich-Tisch-Messgerät zur Ermittlung der Abzugskraftwerte von Crimpverbindungen, verschweißten Verbindungen oder von vielen anderen Möglichkeiten. Da zwischen zwei Messbereichen umgeschaltet werden kann, kann ein breiteres Kabelspektrum gemessen werden als bei Geräten mit nur einem Bereich. Der PullTester 27 ist hervorragend geeignet zur Qualitätsüberwachung in der Produktionsumgebung. Zwei Messbereiche für eine höhere Genauigkeit in einem größeren Spektrum 2 wählbare Abzugsgeschwindigkeiten Motoransteuerung für konstante Ziehgeschwindigkeit Einfaches LCD Display für problemloses Programmieren & Ablesen Wiederholgenaue und präzise Werte Eine Vielzahl an möglichen Kantakthaltern und Leitungsaufnahmen Standard RS 232 Schnittstelle zur Kurvenanalyse mit der optionalen WinCrimp PC Software Verarbeitungsmöglichkeiten: Standard Crimpverbindungen Verschweißte oder gelötete Verbindungen Kabelbinder Zugkraft-Test Isolationsauszugmessung Klemmen-Rückhaltevermögen testen Viele andere Kundenanwendungen Anwendungsbereich: Diese vielseitige Maschine ist, abhängig von der Abzugsgeschwindigkeit und dem Kraftbereich, in vier Versionen verfügbar. Alle Versionen haben zwei Messbereiche, welche separat kalibriert werden können für dünnere Leitungen und für größere Leitungsquerschnitte. Andere Bereiche sind gegebenenfalls möglich. Dies ermöglicht höchstmögliche Genauigkeit für eine größtmögliche Bandbreite von Kabelquerschnitten und Applikationen. PullTester 27-25: 2.000 / 5.000 N (440 / 1100 lbf.) @ 25 / 50 mm/min (0,98 oder 1,97“/min) PullTester 27-50: 2.000 / 5.000 N (440 / 1100 lbf.) @ 50 / 100 mm/min (1,97 / 3,94”/min) PullTester 27-10-25 (special): 5.000 / 10.000 N (1100 / 2200 lbf.) @ 25 / 50 mm/min (0,98 oder 1,97“/min) PullTester 27-10-50 (special): 5.000 / 10.000 N (1100 / 2200 lbf.) @ 50 / 100 mm/min (1,97 / 3,94”/min) Handbediente oder pneumatische Abzugskraftmessgeräte können ungleichmäßige Daten liefern, abhängig von Bediener oder Geschwindigkeit. Einige Prüfvorschriften fordern eine gleichmäßige Abzugsgeschwindigkeit Daher ist der Schleuniger PullTester 27 mit einem Antriebsmotorsystem ausgerüstet, das dies über den gesamten Messbereich sicherstellt und somit genaue und zuverlässige Messergebnisse garantiert. Die Abzugskräfte können wahlweise in Newton, Kilopond oder Poundforce gemessen werden. Die Kontaktaufnahmen und Schnellwechseloptionen können speziell für Ihre Anwendungen konstruiert und hergestellt werden. Außerdem sind viele Haltevorrichtungen bereits verfügbar und auf Anfrage erhältlich. Merkmale: Zwei Messbereiche für ein höchste Genauigkeit über ein größtmögliches Spektrum an Leitungen Motorantrieb garantiert konstante Geschwindigkeit über den gesamten Messbereich 2 wählbare Abzugsgeschwindigkeiten RS 232 Schnittstelle für Kurvenanalyse sowie zum Transfer zu Microsoft® Excel Flexible Konstruktion ermöglicht viele verschiedene Anwendungen Optionen: Kontakt- und Leitungshalter für viele Anwendungen Kundenspezifische Kontakt- und Leitungsaufnahme Schnellwechselhalter WinCrimp Basis-Software Alternative Kraftbereiche Netzwerkkabel und Zubehör Modelle: PullTester 27-25 PullTester 27-50 PullTester 27-10-25 PullTester 27-10-50 Messbereich: Standard: 2’000 N / 5’000 N Spezialversion: 5’000 / 10‘000 N Andere Variationen möglich Masseinheit: Newton (N), Kilopond (Kp), Poundforce (lbf.) Anzeige: 6–stellige LCD Sensorgenauigkeit: 0.2% vom Messbereichsende Max. Abzugshub: 80 mm (3.14”) Abzugsgeschwindigkeit: 2 Geschwindigkeiten: 50 oder 100 mm/min (1,97 oder 3,94″/min) Optional: 25 oder 50 mm/min (0,98 oder 1,97“/min) Auftragsspeicher: Nicht erhältlich Abzugsarten: Abziehen + Ausreißen Überwachung: Über das Gerätedisplay; optional statistische Software Wincrimp für Kraft-Zeit-Verlauf-Darstellung auf PC und statistischer Analyse zur Auswertung, mit der Möglichkeit des Transfers zu Microsoft® Excel Schutzart: IP 20 Schnittstellen: RS 232 Netzwerk: In Kombination mit Crimpkraftüberwachung und Crimphöhenmessgerät via WinCrimp Software. Nur ein Gerät im RS232 Netzwerk. Mehrere Geräte mit RS 232-TCP/IP Adaptern. Abmessungen (L x B x H): 640 x 400 x 300 mm Gewicht: ca. 45 kg CE-Konformität: Die PullTester 27 entspricht vollumfänglich den CE und EMV-Maschinenrichtlinien (mechanische und elektrische Sicherheit, elektromagnetische Verträglichkeit).
MEGA 11-350 DS

MEGA 11-350 DS

Spaltzugprüfmaschine MEGA 11-350 DS für die rationelle Qualitätskontrolle an Pflastersteinen gemäß EN 1338
Funksysteme

Funksysteme

Wir bieten eine umfassende, zuverlässige und erprobte Auswahl an HF-Sendern und -Empfängern für Breit- und Schmalband-Applikationen. Sender/Empfänger für: UHF, S-Band, L-Band digitale, analoge oder Videodaten Ausgangsleistung bis 10 W (Leistungsverstärker verfügbar) Optionen wie z.B. Subchannel auf Anfrage
Agriculture co-tractormaster

Agriculture co-tractormaster

Continental CO-TRACTOR Master Reifen – Produktspezifikationen Modell: Continental CO-TRACTOR Master Typ: Landwirtschaftsreifen für Traktoren und Landmaschinen Verfügbare Größen: Verschiedene Größen, typischerweise für verschiedene Traktormodelle und landwirtschaftliche Maschinen Höhe/Breite: Variiert je nach Größe, typischerweise angepasst an die Bedürfnisse der jeweiligen Maschinen Reifenaufbau: Radial Tragfähigkeitsindex: Variiert je nach Größe, typischerweise von 120 bis 160 Geschwindigkeitsindex: A8 (bis 40 km/h) oder B (bis 50 km/h), je nach spezifischer Größe Profil: Tiefes, robustes Profil für exzellente Traktion und Stabilität auf Feld- und Straßenfahrten Eigenschaften: Traktion: Überlegene Traktion auf verschiedenen Bodenarten wie Schlamm, Erde und Gras, ideal für alle landwirtschaftlichen Aufgaben Stabilität: Optimierte Bauweise für hohe Stabilität und geringeren Bodendruck, um den Boden zu schonen und die Traktion zu maximieren Haltbarkeit: Robuste Konstruktion für hohe Abriebfestigkeit und lange Lebensdauer, auch unter anspruchsvollen Bedingungen Komfort: Verbesserte Dämpfungseigenschaften für ein komfortables Fahrerlebnis und reduzierte Vibrationen Ideal Für: Traktoren und landwirtschaftliche Maschinen, die vielseitige Leistung und Zuverlässigkeit auf unterschiedlichen Böden benötigen Landwirtschaftliche Aufgaben wie Pflügen, Säen und Ernten, sowohl auf Feldern als auch auf Straßen
TMG IO-Link Device Tool V5 - TS -Option IOLS

TMG IO-Link Device Tool V5 - TS -Option IOLS

Für die Entwicklung und Konformitätsprüfung von IO-Link Safety Devices bieten wir unser IO-Link Device Testsystem (TMG IO-Link Device Tool V5.1 - TS) an, welches das am weitesten verbreitete für IO-Link Devices ist und nun um die IO-Link Safety Testoption (TMG IO-Link Device Tool V5.1 - TS - Option IOLS) erweitert wurde. Mit dieser Erweiterung können alle Protokolltests für IO-Link Safety Devices durchgeführt werden. Die IO-Link Standard-Tests müssen für IO-Link Safety-Geräte angepasst werden. Dies wird durch die Erweiterung freigeschaltet. Die IO-Link Safety-Tests werden in funktionale und nur für die Interoperabilität notwendige Test-Cases sowie die sicherheitsrelevanten Tests für den Safety-Communication-Layer (SCL) unterschieden. Die SCL-Tests werden vom TÜV Süd abgenommen. Während die Standard und Professional Editionen die IO-Link Safety Kommunikation nur im Commissioning Mode unterstützen, kann das IO-Link Safety Device hier zu Entwicklungszwecken auch im so genannten "armed mode" betrieben werden. Technische Daten • Basierend auf TMG IO-Link Device Tool V5.1 – TS und dem darin enthaltenen TMG USB IO-Link Master V2 TS - Portklasse A (OSSDe toleriert) - IO-Link Safety Test Option (Softwarelizenz) - PC- Software: Basierend auf dem TMG IO-Link Device Tool – TS - Hinweis: Alle TMG USB IO-Link Master V2 TS mit FW Rev 3.x können aktualisiert werden. Für Master mit FW Rev 2.x bieten wir ein kostengünstiges Hardware-Upgrade an • Testumfang: - IO-Link-Safety Protocol Test - Für alle IO-Link-Safety Devices
Schuhlöffel mit Tester für Rauchmelder

Schuhlöffel mit Tester für Rauchmelder

Schuhlöffel mit Tester für Rauchmelder. Kunststoff Artikelnummer: 919089 Druckfarben: 1 Gewicht: 125 gram
Consulting

Consulting

Callcenter Services und Beziehungsmarketing Telemarketing für Investitionsgüter, IT, Software und Dienstleistung Call-Center Leistungen und Services im Premium Bereich zur Gewinnung neuer Kunden. Im Hauruck-Verfahren lassen sich sicher in kürzester Zeit Tausende von Adressen abtelefonieren und beinahe ebenso viele Termine generieren. Auf den ersten Blick erscheint das verlockend. Genau das werden wir von Saupe Telemarketing nicht für Sie tun. "Denn unsere Philosophie," :Ihre Außendienstmitarbeiter oder Berater werden nach einer solchen Aktion zwar unzählige Gespräche führen, aber nicht zwangsläufig auch viele Erfolg versprechende Leads erzeugen." Das ist der Grund warum wir individuelle Callcenter Lösungen anbieten und seit vielen Jahren praktizieren. Call-Leistungen: So schaffen Sie mehr Termine für Ihren Vertrieb und Aussendienst zu wirtschaftlichen Konditionen. Call-Leisutngen zur aktiven Unterstützung Ihres Vertriebs und Aussendiensts: Unser Ziel und unsere Philosophie im Telemarketing ist es nicht, Ihre Leute auf Biegen und Brechen durch die ganze Bundesrepublik zu jagen, unser Ziel ist es, für Sie und mit Ihnen langfristige, gewinnbringende Beziehungen als Asset aufzubauen und weiter zu entwickeln. So schaffen wir für Sie eine wertvolle Substanz, von der Sie auch in Zukunft profitieren. Denn das sehen wir als unsere wesentliche Aufgabe an. Call-Center und Beziehungsmarketing: Mehrwert für Ihr B2B-Marketing Wir haben uns darauf spezialisiert, anspruchsvolle Themen in einen Gesamtprozess einzubinden. Denn auch im scheinbar „unpersönlichen“ B2B-Geschäft spielt das persönliche Beziehungsgeflecht die entscheidende Rolle. Wir verstehen uns deshalb nicht als Call-Center im klassischen Sinn. Saupe Telemarketing ist vielmehr Bestandteil eines in sich geschlossenen Beziehungsmanagement-Systems, der Start einer kontinuierlichen, für beide Seiten fruchtbaren Beziehung. Unsere Telemarketing Dienstleistungen: Aktive Call-Center und Telemarketing-Leistungen bedeutet für uns: Kundendaten und Informationen zentral zusammenführen, Informationen bündeln und verdichten, Neukundenpotenziale sichtbar machen – für eine kontinuierliche, vorausschauende und damit erfolgreiche Marktbearbeitung. Die Berater bei Saupe Telemarketing sehen ihre Aufgabe als Teil eines Gesamtprozesses: Wir sind Ihr Partner für Direktmarketing, Akquise und Consulting – wenn Sie nachhaltig Kunden gewinnen, betreuen und binden wollen. Call-Center Leistungen: Das können Sie von uns erwarten. Call-Center Leistungen ausschließlich für B2B-Marketing (Unternehmenskontakte) Inhouse: qualifizierte Callcenter-Agents im eigenen Unternehmen (Einstellungsverfahren und Tests) Ausreichend Zeit für jedes Telefonat – keine begrenzende Zeitvorgabe, keine Routine, kein Ablesen von Checklisten Langjährige Erfahrungen rund um den Verkauf komplexer technischer Produkte und Dienstleistungen Ihre Kunden erleben am Telefon ein Stück ansprechende, überzeugende Firmenkultur Erfahrungen werden zeitnah ausgewertet und in Maßnahmen umgesetzt Wir legen bei unseren Mitarbeiter/-innen Wert auf verantwortungsbewusstes Mit- und Vorausdenken und professionelles Vorgehen. Wirtschaftliche Lösungen zur Gewinnung neuer Kunden und neuer Märkte Kennen-Lern-Angebot: Testen Sie uns und geben Sie uns Ihre anspruchsvollsten Aufgaben. Das Arbeitsumfeld bei Saupe Telemarketing Unsere Mitarbeiter/-innen arbeiten meist über einen langen Zeitraum für denselben Kunden Kleine Telemarketingteams geben Raum für Kreativität Unsere Call-Agents telefonieren maximal 6 Stunden pro Tag und maximal 4-5 Tage pro Woche Bei uns gibt es kein Großraumbüro mit Telefonboxen Wir legen viel Wert auf Schulung und persönliche Entwicklung Das könnte Sie noch interessieren: Erste Schritte mit Saupe Telemarketing Saupe Telemarketing Kennenlern-Angebot Qualifizierung von Adressen Telemarketing unterstützend zum Webmarketing Hier finden Sie aktuelle Informationen zu unserer Branchen-Expertise und unseren Referenzen. Für weitere Informationen zu Call-Lenter-Leistungen für Investitionsgüter, Industrie, Handel, IT- und Sofware-Lösungen erreichen sie uns unter: +49 7351 181318-10
Elektronik für Landmaschinen

Elektronik für Landmaschinen

Elektronik für Landmaschinen, 0,3mm Pich, Traceability, AOI, X-Ray, Boundary-Scan, Flying-Probe-ICT, Muster sowie Serienproduktionen, Schnell und zuverlässig, IPC-A-610 Kl. 2, IPC-A-610 Kl.3
CLUNGENE COVID-19 Antigen Rapid Test Cassette Schnelltest Nasenabstrich 25er Pack

CLUNGENE COVID-19 Antigen Rapid Test Cassette Schnelltest Nasenabstrich 25er Pack

HOHE SPEZIFITÄT (99,4 %) CLONGENE SWAB ABSTRICH TEST für den vorderen Nasenraum BAFARM LAIENZULASSUNG: NO. 5640-S-168/21 LIEFERUMFANG 25 Testkassetten 25 sterile Einweg-Abstrichtupfer 25 Extraktionsröhrchen 25 Tropfspitzen Extraktionspufferlösung Arbeitsstation Bedienungsanleitung Hersteller: Hangzhou Clongene Biotech Co., Ltd. HIGHLIGHT CLONGENE SWAB ABSTRICH TEST für den vorderen Nasenraum Hohe Spezifität (99,4 %) Sensivität 97,1 % BfArM Zulassung: AT079/20 Vom Paul-Ehrlich-Instituit (PEI) validiert und gelistet Leicht zu bedienen Zum qualitativen Nachweis einer aktuten SARS-CoV-2 Infektion Nasale, naso- oder oropharyngeale Testdurchführung Gelistet beim deutschen BfArM sowie französischem Gesundheitsministerium, evaluiert vom PEI Testergebnis liegt bereits nach 15 Minuten vor 25 versiegelte Testkassetten und Zubehör Testlagerung bei Raumtemperatur Alle Testkomponenten sind enthalten Pflegeheime, Krankenhäuser, Betriebe können Antigen-Schnelltests großzügig nutzen, um Personal, Besucher sowie Patienten und Bewohner regelmäßig auf das Corona-Virus zu testen. Der vom Paul-Ehrlich-Institut evaluierte Schnelltest wird mit sämtlichem benötigten Zubehör geliefert und kann direkt am Point of Care durchgeführt werden. Bereits 15 Minuten nach Auftragen der Patientenprobe lässt sich das Testergebnis ablesen. Es wurde keine Kreuzreaktivität mit Influenza-Viren oder dem humanen Corona-Virus (229E, OC43, NL63, HKU1) festgestellt. BESCHREIBUNG Der CLUNGENE Covid-19 Antigen-Schnelltest ist ein Lateral-Flow-Immunoassay zum qualitativen Nachweis einer akuten SARS-CoV-2 Infektion. Der vom Paul-Ehrlich-Institut evaluierte Schnelltest wird mit sämtlichem benötigten Zubehör geliefert und kann direkt am Point of Care durchgeführt werden. Bereits 15 Minuten nach Auftragen der Patientenprobe lässt sich das Testergebnis ablesen. Es wurde keine Kreuzreaktivität mit Influenza-Viren oder dem humanen Corona-Virus (229E, OC43, NL63, HKU1) festgestellt. Zum Nachweis des SARS-CoV-2-Nucleocapsid-Antigens wird während der aktuten Phase der Infektion ein Nasal-, Nasopharyngeal- oder Oropharyngealabstrich entnommen. Für den nasopharyngelaen Abstrich wird ein steriler Abstrichtupfer durch das Nasenloch eingeführt und eine Abstrichprobe aus dem hinteren Nasen-Rachenraum entnommen. Für den Oropharyngealabstrich wird der Tupfer in den hinteren Pharynx- und Tonsillenbereich eingeführt und über beide Tonsillensäulen und Oropharynx gerieben. Der nasale Abstrich wird an der Nasenschleimhaut entnommen - dafür wird der Abstrichtupfer ca. 2,5 cm weit in das Nasenloch eingeführt und dort mehrfach an der Nasenschleimhaut entlang geführt. Der Vorgang wird mit dem selben Tupfer im anderen Nasenloch wiederholt. TECHNISCHE DATEN Die neuartigen Coronaviren (SARS-CoV-2) gehören zur Gattung β. COVID-19 ist eine akute Infektionskrankheit der Atemwege. Im Allgemeinen sind alle Menschen anfällig. Derzeit sind die mit dem neuartigen Coronavirus infizierten Patienten die Hauptinfektionsquelle; asymptomatisch infizierte Patienten können ebenfalls eine infektiöse Quelle darstellen. Basierend auf der aktuellen epidemiologischen Untersuchung beträgt die Inkubationszeit 1 bis 14 Tage, meist 3 bis 7 Tage. Die Hauptmanifestationen sind Fieber, Müdigkeit und trockener Husten. In einigen Fällen sind verstopfte Nase, laufende Nase, Halsschmerzen, Myalgie und Durchfall festzustellen. CLUNGENE Covid-19 Antigen-Schnelltest Lateral-Flow-Immunoassay Qualitativer Antigentest Beim deutschen BfArM (Bundesinstitut für Arzneimittel und Medizinprodukte) sowie französischen Gesundheitsministerium gelistet Evaluiert vom Paul-Ehrlich-Institut Auf der gemeinsamen Liste der Europäischen Kommission für COVID-19 Antigen-Schnelltests Das Testergebnis von Schnelltests, die auf der Liste der Europäischen Kommission für COVID-19 Antigen-Schnelltests stehen, wird in allen Mitglieds-Staaten der EU anerkannt. Testmaterial: nasopharyngealer, oropharyngealer oder nasaler Abstrich Keine Kreuzreaktivität mit Influenza-Viren, Rhinoviren oder humanen Coronaviren (229E, OC43, NL63, HKU1) Testergebnis nach 15 Minuten ablesbar Lagerung zwischen 4 - 30°C Testdurchführung bei Raumtemperatur (15 - 30°C, Testmaterial bitte vorher auf Raumtemperatur bringen) Jeder Test einzeln im versiegelten Folienbeutel Nur zur Verwendung durch medizinisches Fachpersonal Bitte beachten Sie, dass der CLUNGENE Covid-19 Antigen-Schnelltest vom Rückgaberecht ausgeschlossen ist Menge: 1 Packung mit 25 Schnelltest Test Typ: Nasal Spezifität: 99,4 % Sensivität: 97,1 % BAFARM LAIENZULASSUNG: NO. 5640-S-168/21
eKAM Electronic primary injection test set

eKAM Electronic primary injection test set

eKAM is the new fully automatic electronic primary injection test equipment. e KAM test system includes two portable units: one control unit with a large graphical display, that adjusts the output, and one current unit (up to 2000, 3000, 5000A). It can also perform Step and Touch tests and ground resistance tests. Main features Fully automatic Two portable units: control and current units High current output: up to 2000 A, 3000 A and 5000 A Variable output frequency: 15 – 500 Hz CT ratio, burden and polarity test Large graphic display Advanced Test & Data Management Software for test set control, results storage and analysis Step & touch plus ground resistance tests with STLG option Reduced timing test USB interface and Ethernet interface for PC connection IEC 61850-9-2 sample values protocol interface Compact and lightweight Tests performed High current 2000, 3000, 5000, 7000 A CT ratio; CT polarity CT burden secondary side CT IEC 61850-9 CB operation time Earth impedance Line impedance Step & touch voltage
PT18-10 MK2 Test Set

PT18-10 MK2 Test Set

PT18-10 Mk2 wurde für die sichere Prüfung von Kabel- und Verbindungssystemen entwickelt, mit variabler Ausgangsspannung und automatischem Lastentladesystem. ±18kV Gleichspannungsausgang 10mA Ausgangskapazität Sowohl Spannung als auch Strom werden an den Hochspannungsausgängen gemessen Automatisches Erdungssystem zum Entladen kapazitiver Lasten Hochspannungsausgang mit Stecker- und Buchsensystem Schlüsselschalter zur Verhinderung unbefugter Bedienung Null-Volt-Verriegelung Visuelle Anzeige bei Versagen des Prüflings Automatische Netzspannungsauswahl Datenblatt Bedienungsanleitung
PT15-10S Mk2 Test Set

PT15-10S Mk2 Test Set

Hochleistungs-PT15-10S Mk2 Gleichstrom-Testgerät: variable Ausgangsspannung bis zu 15 kV DC, automatische Lastentladung und zuverlässige Messungen für genaue Tests 0 bis 15 kVdc Ausgangsspannung 10 mA Ausgangskapazität Sowohl Spannung als auch Strom werden am Hochspannungsausgang gemessen Automatisches Erdungssystem zur Entladung kapazitiver Lasten Hochspannungsausgang Stecker & Buchse Mit Schlüssel betätigter Versorgungsschalter zur Verhinderung unbefugter Bedienung Null-Volt-Verriegelung Visuelle Anzeige bei Versagen des Prüfstücks Kompaktes Gerät mit leichtem, isoliertem Gehäuse Datenblatt Bedienungsanleitung
ART3V RELAY TEST SYSTEM

ART3V RELAY TEST SYSTEM

3-f Voltage output from 1-f supply 0-450V f-N output voltage 20VA/phase maximum output Variable Frequency 30-999.9Hz Phase shift ±180.0° Multi-function timing system USB keyboard for comment USB data storage. Ideally suited to testing G59 & G99 schemes Step change of phase and df/dt Large 6.5” back-lit colour LCD Automatic mains voltage selection Fully Programmable test procedures Rugged case and weighs under 9kg The new ART3V Relay Test System brings new features to our range of relay test equipment making it far more adaptable. The new output voltages are higher and have a finer level of accuracy and control. The new full colour LCD provides more test detail, making it easy to understand. The ART3V user interface is an improvement of the DVS3 mk2 allowing simple testing of complex voltage and loss of mains protection systems. The ART3V has vastly improved accuracy, stability, and features. Designed to be the trusted and reliable voltage source for relay testing. The ART3V has been designed using the latest digital technology to generate a highly stable and accurate output with very low distortion. Each phase output is individually adjustable for voltage, frequency and phase angle. The unit is controlled by a simple user interface within defined menus. Values may be either typed in at the capacitive keypad or finely varied using a smooth rotary encoder. Bespoke test procedures can be created for step changes of any output variable at set times or with automatic timing of the response of the relay under test. The ART3V has a colour back-lit display to provide an easy to read user interface. Menu options are selected by dedicated buttons on the panel, allowing easy mode change. All information is displayed including contact set status, and a phasor diagram. The ART3V Relay Test System is ideally suited for testing G59/G99 protection, including loss of mains protection. Vector surge and df/dt (ROCOF) relays can be simply tested and timed, as well as other protection requiring one to three voltages, including: Under and over frequency relays Under and over voltage relays Synchronising relays df/dt & ROCOF relays Vector surge relays Transducers In conjunction with the ART3C or a current source (such as the 200ADM-P), the ART3V can be used to test protection circuits, including: Directional relays Distance protection Phase angle relays Power relays Power transducers Output The output of the ART3V has 4mm safety sockets for phases A, B, C and neutral. The neutral connection may be omitted for a delta connection. The neutrals can be linked for a star connection using the provided accessory. Timing System The timing system on the ART3V is flexible and transparent with different modes of operation. USB Data The ART3V can be connected to a USB keyboard for adding comments to tests. Each test is stored to a USB memory key with each comment. The data is stored in a *.CSV format allowing it to be opened in all types of desktop PC spreadsheet software. Modes of Operation Output Adjust This mode allows full control of frequency, voltage and phase. Phase Lock Mode The frequency and phase of the output can be controlled by an external reference in phase lock mode. The reference may be the mains supply to the ART3V, an external voltage, current. This mode allows testing of directional and distance protection in conjunction with an external current source. Fault Config Mode Fault Config mode allows extra flexibility in testing complex timed events or several sets of values that must be applied to a relay in turn. This mode allows three sets of values to be set in advance (pre-fault, fault, and post-fault values). The ART3V may be set to switch from one state to the next on a change of contact or after a specific time. In addition, the timer may be set to start or stop on any one of the state changes or a change of contact state. This mode allows frequency, phase and voltage to be changed simultaneously if required. Test configurations can be save to USB. More complex configurations can be loaded from the USB, such as a complete G59/G99 relay test, such as relay stability tests. df/dt and ROCOF (Rate Of Change Of Frequency) Loss of mains protection often takes the form of a df/dt relay, sensitive to the rate of change of frequency over time. The ART3V is able to generate a swept frequency output with accurate rates of change of frequency between preset frequencies. WEIGHT 8.9 kg DIMENSIONS 419 × 325 × 195 mm SUPPLIED ACCESSORIES Output lead set Lead set case Mains lead Spare fuse set Operating manual
Z-OVR Cable Impedance Test System

Z-OVR Cable Impedance Test System

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The Z-OVR Cable Impedance Test Set is a cable impedance test system for the measurement of impedance of overhead lines and underground cables. The system consists of a separate control unit containing all metering and control functions and an output transformer that provides isolation of the output current and feedback voltage. A current is injected into the line under test and the resultant magnitude and phase angle of the voltage across the line is measured. The current, voltage, phase angle and impedance of the line (Z & X) under test are displayed. In addition, the harmonic content of the voltage and current can be displayed. The unit has data logging facilities using a standard USB memory key. Date, time, current, voltage, phase angle, and frequency are stored to a CSV file on the memory key along with a comment entered using the supplied USB keyboard. Pressing the “store” pushbutton causes a new set of values to be written to the CSV file. The output has three taps (75V, 150V & 300V), allowing the measurement of impedance of a wide range of lines and cables. All metering is true rms. Four current ranges (2.000, 10.00, 20.00 and 100.0A) and three voltage ranges (10.00V, 30.00V and 300.0V) are provided. The output transformer unit uses 6mm safety connectors for all outputs and 4mm safety connectors for inputs. A block of connectors is provided adjacent to the output to allow easy parallel connection of cables for parallel measurements on all three phases. The Z-OVR Cable Impedance Test Set is provided with a set of four 10m 12mm2 duplex measurement cables. These provide a 12mm2 conductor for current injection and a 6mm2 conductor for voltage feedback in each cable. WEIGHT 26 kg DIMENSIONS 450 × 275 × 305 mm SUPPLIED ACCESSORIES Earth lead Spare fuse set Operating manual USB keyboard USB memory key Mains lead 5 metre long 1 x 10m Earth Kelvin connection lead 3 x 10m Overhead Kelvin connection leads Link lead to connect parallel connection block Power and metering interconnection leads 5 metre long OPTIONAL ACCESSORIES Trolley mounting system, Part no. A204-0005
STS 5000 Multifunction substation test set

STS 5000 Multifunction substation test set

STS 5000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid. Main features Fully automatic Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000 Variable output frequency: 15 – 500 Hz Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV) 2000 v AC high-pot test Local control by large color display PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report IEC 61850-9-2 communication protocol Patented technology for Capacitance and Tan Delta measurement USB interface and Ethernet interface for PC connection. Compact and lightweight Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side ALF ISF CT excitation curve CT knee voltage CT winding resistance burden resistance voltage withstand rogowski coil low power transformer CT IEC 61850-9 VT ratio VT polarity VT burden secondary side VT IEC 61850-9 PT ratio PT vector group PT winding resistance OLTC tap changer dynamic resistance; PT excitation current PT no load current PT short circuit impedance PT leakage reactance Micro-ohmmeter CB operation time
STS 5000 Multifunction substation test set

STS 5000 Multifunction substation test set

STS 5000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid. Main features Fully automatic Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000 Variable output frequency: 15 – 500 Hz Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV) 2000 v AC high-pot test Local control by large color display PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report IEC 61850-9-2 communication protocol Patented technology for Capacitance and Tan Delta measurement USB interface and Ethernet interface for PC connection. Compact and lightweight Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side ALF ISF CT excitation curve CT knee voltage CT winding resistance burden resistance voltage withstand rogowski coil low power transformer CT IEC 61850-9 VT ratio VT polarity VT burden secondary side VT IEC 61850-9 PT ratio PT vector group PT winding resistance OLTC tap changer dynamic resistance; PT excitation current PT no load current PT short circuit impedance PT leakage reactance Micro-ohmmeter CB operation time
100A/E MK3 Secondary Current Injection Test Set

100A/E MK3 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100A/E mk3 secondary current injection test set has been designed to give the maintenance and commissioning engineer a large number of facilities in one self-contained instrument.The unit is portable, compact and simple to use. The mains supply for the unit is either 240V±10% or 115V +10% -6% at either 50 or 60Hz. Full load can be obtained at the supply voltage extremes. The current and voltage outputs are independently controlled and metered. The output current and voltage are displayed on large, clear panel instruments. An additional four range CT is provided, extending the ammeter range down to 0-100mA. All of the outputs are fully isolated by means of double wound transformers. The timing system on the 100A/E is very flexible, without compromising ease of use. Four modes of operation and two contact inputs are provided allowing for a wide range of events to be timed. Both contact inputs automatically select for normally open or normally closed contacts. Operation of the different timing modes is described overleaf. Internal start mode starts the timer when the ‘ON’ pushbutton is pressed, and stops the timer when the first contact set changes state. This mode is ideally suited to timing over-current relays. Single contact mode starts and stops the timer on the first and second changes of state of the first contact set, and dual contact mode starts the timer from the first set of contacts and stops it from the second set. These modes allow reset and re-close times of protective devices to be easily measured. The final mode of operation of the timer starts the timer when the current exceeds 20% of the selected metering range, and stops it when the current falls below 20%. This allows the timing of trips with no auxiliary contacts such as miniature circuit breakers. Automatic control has been provided such that all outputs can be switched off once the device under test has operated. The automatic control can be switched in or out of circuit for all outputs, enabling setting up procedures to be carried out. The instrument is housed in a robust case complete with a protective cover and fold-away carrying handles. The current output on the unit has eight ranges, allowing the selection of output voltages up to 150V and output currents up to 200A. The voltage output on the unit has three ranges, allowing the selection of output voltages up to 500Vac and 250VDC. If using a 100ADM-F with the 100A/E mk 3 unit you will need to to order A0006-0010 lead set. The output of the 100A/E mk3 secondary current injection test set is a true RMS analogue system with separate instruments for current and voltage. AC current is metered by a dual scaled ammeter reading 0-1A and 0-5A. AC voltage is metered by a dual scaled ammeter reading 0-300V and 0-600V. The output may be automatically switched off at the end of the test to safeguard the relay under test. This is available for both the voltage and current output. WEIGHT 33 kg DIMENSIONS 490 × 300 × 300 mm SUPPLIED ACCESSORIES Operating manual 2m Mains lead Non-latching contact lead 100AL lead set Spare fuses OPTIONAL ACCESSORIES 100ADM-F, Part no. 006 100A/E Filter, Part no. A0006-0010
TPT9000 Transformer Polarity Tester

TPT9000 Transformer Polarity Tester

Fast polarity testing of both voltage and current transformers. Compact and light Easy to use, plug & play Smart detection of incorrect connection Proving unit included in the kit as standard Fused lead sets included for user safety Supplied in a protective case. Long battery life Built in battery monitor The TPT9000 Transformer Polarity Tester is used for determining the correct polarity of current and voltage transformers. This device is a smart plug and play instrument designed for Commissioning Engineers. A lightweight instrument it comes with magnetised back panel, making it for storage on metallic walls or panels. TPT9000 automatically detects if the transformer has been connected incorrectly. The device comes with a proving unit to check the correct operation of the unit in the field. A set of 600V CAT IV fused test leads terminated in shrouded 4mm connectors is also included with the unit, along with 4 F500mA HRC fuses. The instrument is designed to be used on ‘dead’ systems (i.e., no externally supplied voltages are present on the test object). We strongly advise you not to connect the TPT9000 to a live system. Always make sure that the power of the device under test is off. TPT9000 Transformer Polarity Tester is designed for use in industrial and electrical substation environments on altitude level of maximum 2000m above sea level. Operating temperature is between 0°C and 45°C, while storage temperature is -20°C to 60°C. TPT9000 requires a single PP3 9V battery to operate. Battery level is automatically monitored, and the device will not perform a test if the battery voltage is below a useable level. WEIGHT 0.6 kg DIMENSIONS 118 × 79 × 32 mm SUPPLIED ACCESSORIES Proving unit 1 off 1m Black fused lead 1 off 1m Red fused lead 1 off 1m Blue fused lead 1 off 1m Brown fused lead Operating & Maintenance Manual Unit carry set case 9V battery OPTIONAL ACCESSORIES/SPARES Proving Unit, Part No. 249-0001 Complete replacement output lead set, Part No. A249-0002 Carry Case, Part No. A249-0003
200ADM-P Secondary Current Injection Test Set

200ADM-P Secondary Current Injection Test Set

The 200ADM-P is a current injection system with a wide range of advanced features including phase shift, data storage and harmonic analysis. 0-200A output current True RMS metering with 1 cycle capture Variable auxiliary ac voltage/ current output with phase shift Auxiliary metering input V, f, Φ, Z, P, S, PF, CT ratio, harmonics & more Variable auxiliary output 12-220Vdc Multi-function auto-ranging timing system Current limit mode for fine control Data storage to USB memory key including waveform & harmonics USB keyboard/printer interface Automatic mains voltage selection The 200ADM-P Secondary Current Injection Test Set has a range of outputs allowing injection of currents between 1mA and 200A. Voltages up to 240V are available on the main outputs allowing high impedance current relays to be tested. True RMS metering with single cycle capture is provided. 4 current ranges allow the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used throughout for safe, reliable convenience. The 200ADM-P Secondary Current Injection Test Set has a flexible auxiliary ac output that can be used at up to 260V for voltage relays or up to 10A for current relays. The phase and frequency of this output are fully adjustable. This combination of voltage and current allows testing of relays that require two voltages, one voltage and one current or two currents. An auxiliary metering module is provided that meters ac and dc voltage, current and frequency from the auxiliary outputs or external signals. The module can also take measurements in conjunction with the main current output to meter phase angle, power, impedance, CT ratio and harmonics. A variable stabilised DC supply with current limit is provided to power the relay under test. WEIGHT 22.6 kg DIMENSIONS 500 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Output lead set Mains lead Sparefuses USB keyboard USB memory key Shoulder strap (except Pelicase unit) OPTIONAL ACCESSORIES 100ADM-F, Part no. 006 100AL Mk2 / Mk3, Part no. A199-0003
18kV 10mA DC Tester PT18-10 MK2

18kV 10mA DC Tester PT18-10 MK2

Ultra lightweight (6.9kg) 1-200Adc test current with <2.5% ripple Supplied with standard 3m output lead set 0.1μΩ resolution mV, A, and m/μΩ displayed simultaneously USB memory key for data storage USB keyboard for comment entry Pre-settable test current with three buttons to store user test currents Large back-lit liquid crystal display Universal supply voltage 90-264V Optional current clamp to allows testing of objects with both sides earthed The PT18-10 mk2 high voltage dc test set is designed to perform tests on installed cable and jointing systems. The 18kV 10mA DC Tester has a variable output voltage with a maximum of ±18kVdc with a maximum charging capability of 10mA. A zero-volt interlock is fitted that prevents the output being switched on unless the output control is at zero. Units include an automatic load discharge system that discharges the cable under test when the output is switched off or a breakdown occurs. Internal dumping system can discharge a maximum of 2.5kJ on each output, corresponding to 10µF at 18kV. In the event of a test object failure, the overload circuit will automatically switch off the output voltage and earth the output via the internal discharge circuit. A DP20 discharge probe is supplied as standard with the PT18-10 mk2, 18kV 10mA DC Tester, allowing higher load capacitances to be safely discharged. The 18kV 10mA DC Tester has an internal fail-safe automatic discharge system with the following ratings: Max. discharge voltage (kVdc) 20kVdc Highest discharge energy 2.5kJ Highest discharge capacitance 10μF Max. discharges per hour 4 The automatic discharge switch is controlled by a solenoid. It may produce a noticeable hum when the HT output is energised. Output voltage is metered by two large, linear, analogue instruments marked 0-20kV. Meanwhile, current is metered by two further analogue instruments with 0-10 scale marking. The meters read 0-10mA directly, or 0-1mA when the ÷10 push button is operated. The HV output from the unit uses a high quality plug and socket system, allowing for easy cable replacement. High voltage plugs are protected in transit by plastic covers and are fully de-mountable. Screened 5 metre long high voltage output cables are provided with the equipment terminated with large clips. The mk2 units introduce automatic 115/230V mains voltage selection. That along the padded bag ensure maximum protection during transit.
TDX 5000 Tan Delta and capacitance test set

TDX 5000 Tan Delta and capacitance test set

TDX 5000 is developed as a compact solution for high voltage Capacitance and Tan Delta (Dissipation Factor) measurements. Using the reactor option, TDX 5000 can also perform tests on rotating machines. Main features Fully automatic Variable output frequency: 1 – 500 Hz Output voltage up to 12 kV Tan Delta, capacitance, dissipation factor measurements and exciting current test RCTD – compensating reactor module allows increasing the test current and getting the maximum test voltage with high capacitive burdens PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Patented technology for capacitance and Tan Delta measurement Light and compact Tests performed Tangent Delta Capacitance
100ADM MK5 Secondary Current Injection Test Set

100ADM MK5 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100ADM mk5 Secondary Current Injection Test Set provides commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate. The 100ADM mk5 keeps the familiar user interface of previous models but adds a new metering system that accurately measures the RMS of a single cycle. It also features a new current limit mode to provide very fine control of very low currents, even into low impedance loads. Current limit mode also assists in testing self-powered overcurrent protection as fitted to many 11kV ring main units. The unit has a range of outputs allowing injection of currents as low as a few mA and as high as 100A. Voltages up to 240V are available on the main outputs, allowing high impedance current relays and voltage relays to be tested. Four true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety. The 100ADM Mk5 Secondary Current Injection Test Set is comprehensively protected by overcurrent, duty cycle and thermal trips, and keeps the user fully informed of any trip condition. A stabilised DC supply is provided to power the relay under test, along with an independently switched and isolated 110V AC output. The back-lit display on the 100ADM mk5 is bright and clear with a wide viewing angle. The results of a test can be seen here as they appear on the display A very flexible two channel timing system is provided, allowing trip times, reset times and re-close times to be quickly measured to a high degree of accuracy. The timer auto-ranges to measure from 1ms to 99999.9s. The 100ADM can be used to test many types of single phase secondary protection including: 27/59 Over and under voltage relays 37 Under current 51 IDMT relays 50/76 Instantaneous overcurrent 59G Neutral voltage displacement 79 Auto-reclosers 2 Time delay relays 51G/50G Earth fault relays 67 Directional overcurrent (basic tests) 52 Miniature circuit breakers Tripping relays Thermal relays 90V Voltage regulating relays WEIGHT 23.9 kg DIMENSIONS 560 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Mains lead Output lead set Spare fuses Carry strap OPTIONAL ACCESSORIES 100ADM-F, Part no. 006
PCU1-SP MK2 Primary Current Injection Test Set

PCU1-SP MK2 Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The PCU1-SP mk2 is a medium powered primary current injection set offering output currents up to 5000A (11.5kVA for 40seconds). The system consists of a separate control unit containing all metering and control functions and a loading unit, such as the NLU200, NLU2000 or the NLU5000, that provides the high current output. The PCU1-SP mk2 are ideally suited to primary current injection, stability testing and circuit breaker testing. In addition, the SP version offers direct-reading CT ratio and polarity tests and a 100A secondary injection output. Two loading units are available, delivering a maximum output current of 2000A or 5000A. Each loading unit has three output taps to allow for a wide range of load impedances. For example, the NLU5000 may be configured to either give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V range or 1250A on the 9.2V range. *The above is an image of the PCU1-SP and Loading Unit The control unit is rated at 11.5kVA with a 2 second overload capability of 23kVA using pulse mode. All metering is digital and a memory facility is provided to hold the current reading when the output trips or is switched off. The current is switched by a solid state device and is automatically switched off when the device under test trips. The PCU1-SP systems have a high accuracy timing system, allowing timing tests to be carried out to a resolution of 1ms. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available to test under and over current devices, re-closers, under and over voltage devices, current trips and circuit breakers. A full range of high current output leads are available to complement the system in a range of lengths. WEIGHT 26 kg DIMENSIONS 450 × 275 × 305 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set OPTIONAL ACCESSORIES Trolley mounting system, Part no A204-0005 100ADM-F, Part no. 006 100AL MK2 / MK3 Lead Set, Part no. A199-0003
HV TROLLEY2 High Voltage AC Test System

HV TROLLEY2 High Voltage AC Test System

20kVA output capability 0-3kV to 0-15kV options available Accurate digital metering Key operated supply switch Dual overload protection Variable electronic trip 10-110% of rated output Voltage and current metering Optional 5s – 5min test timer External 24V interlock and zero-volt interlock Emergency stop switch The HV trolley2 series of units are high power AC flash test sets with a 20kVA output capability. Single Trolley Version The maximum output voltage can be customised to be any voltage up to 15kV. The unit is housed in a rugged aluminium enclosure with a cover to protect the control panel. It is mounted on wheels to allow easy movement within a production environment. The HV trolley2 is provided with accurate digital voltage and current metering and a variable electronic trip. An external interlock input is also fitted to the unit. Outputs are provided to drive 24V warning beacons. The HV output is connected to the test object by a high voltage cable 5m long.
T 1000 PLUS Secondary injection relay test set

T 1000 PLUS Secondary injection relay test set

Multi-tasking test set designed for testing relays and transducers Max current output: 250 A Max AC voltage output: 250 V Max DC voltage output: 300 V Frequency generator: 15 ÷ 550 Hz Phase angle shifter Battery simulator 20 ÷ 260 V DC Oscilloscope function for current and voltage USB port – Microprocessor controller Test results and settings saved into local memory TD 1000 Plus model with two current outputs and high power at 15 Hz. T1000 PLUS is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment. Tests performed Distribution relays Smart grid relays Single phase relays High burden relays
Stoil Cell For dielectric oil test

Stoil Cell For dielectric oil test

Oil cell for the HV test of dielectric oil The option allows the testing of the insulation characteristics of the oil by checking if there is no contamination. Main features Maximum test voltage: 12 kV Cell volume: about 1l Capacitance of the empty cell: 60 pF. Tests performed Tangent Delta
CU-Ps Primary Current Injection Test Set

CU-Ps Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The CU-Ps primary current injection test set is ideally suited to commissioning and maintenance testing where very high currents are required. The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry, and is linked to the loading unit by control and metering cables. The control unit may be used with one of two loading units providing between 5000A or 6000A for 5 minutes or up to 10 or 12kA for short periods. Each loading unit has two outputs which may be connected in series or parallel for maximum flexibility. For example, the PLU-6k may be configured to either give a maximum current of 3000A at 6.6V or 6000A at 3.3V. The control and loading units are each housed in tough steel cases fitted with castors and protective lifting handles. The loading units have a small plan area to allow them to be positioned as close as possible to the test object, minimising power requirements and maximising the available current. The CU-Ps control unit is shown here with a PLU-6k loading unit. This combination may be used to inject currents of up to 6000A for 5 minutes or 12000A for 1 second. The CU-Ps primary current injection test set is ideally suited to all primary current injection tasks, including testing under and over current relays, circuit breakers and CT ratio testing. The control unit is rated at 20kVA and has digital metering. A memory facility is provided on the metering to hold the current reading when the output trips or is switched off. The current is automatically switched off when the device under test trips. The CU-Ps systems have a high accuracy timing system with 1ms resolution. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available for under and over current devices, reclosers, under and over voltage devices, current trips and circuit breakers. The AC output current is metered by a true RMS memory ammeter (acquisition time 20ms) with a liquid crystal display. The current metering has 3 ranges corresponding to 10%, 50% and 100% of the maximum rating of the loading unit. In addition, a 200% metering range is enabled in pulse mode for the 0.2s, 0.5s and 1s settings only. The CU-Ps systems have a flexible timing system with two contact inputs and 5 operating modes. Each contact circuit automatically selects for N/O or N/C contacts, and the status of each contact input is shown by an LED. The timing channels may also be triggered by a dc voltage between 24 and 240V. *Pulse mode applies current to the load for a maximum of the specified time. If contact set 1 changes state or the current drops below 20% of the metering range during the pulse time, the timer is stopped. The maximum output current is increased in pulse mode. The maximum obtainable current is set by the impedance of the test object and output leads. **Current operated mode is used to time circuit breakers with no auxiliary contacts. The timer is started when the current exceeds 20% of the selected metering range (e.g. 1000A on the PLU-5k 5000A range). The timer stops when the current falls. All test results from the CU-Ps can be stored in a USB memory key. The unit has a real-time clock to time and date-stamp all results. To log the results, first enter a comment for your results using the optional keyboard, and then select AUTO STORE. Whenever the timer stops, the time, current and all other parameters are added to a spreadsheet file on the USB key. You can then view the current set of results on the display or take the USB key out and open the file on your PC. All results are stored in a folder on the USB key named with the test date in a file named with the time. The CU-Ps primary current injection test sets and loading units are CE marked and are designed to meet the requirements of BS EN61010. The system is protected by electronic trips on the outputs, circuit breaker and fuse on the mains input, and a circuit breaker on the control unit output. The unit also has a duty cycle trip on the loading unit output and thermal protection. WEIGHT 115 kg DIMENSIONS 660 × 400 × 740 mm OPTIONAL ACCESSORIES A range of output lead sets are available to complement the CU-Ps system with current ratings between 3000A and 6000A. The leads are double insulated and have good flexibility. SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set
Bump Tester und Gas Kalibrator

Bump Tester und Gas Kalibrator

Gesetzliche Vorschriften und die Notwendigkeit des täglichen Stoßprüfens erzeugen ein starkes Bedürfnis von Gastests. Gasdetektoren spielen eine wichtige Rolle für die Sicherheit von Menschen und Anlagen. Calibration Gas Description Ni-Br regulator Stainless steel regulator Non-reactive gases Suitable Suitable H2S Suitable Suitable SO2 Suitable Suitable NO Not recommended Suitable NO2 Not recommended Suitable Cl2 Not suitable Suitable NH3 Not suitable Suitable HCL Not suitable Suitable PH3 Not suitable Suitable SiH4 Not suitable Suitable HCN Not suitable Suitable
Elektro-Rütteltisch

Elektro-Rütteltisch

Elektro-Rütteltisch zur Normgerechten Herstellung von Betonprobekörper