Finden Sie schnell pruefung für Ihr Unternehmen: 150 Ergebnisse

TDX 5000 Tan Delta and capacitance test set

TDX 5000 Tan Delta and capacitance test set

TDX 5000 is developed as a compact solution for high voltage Capacitance and Tan Delta (Dissipation Factor) measurements. Using the reactor option, TDX 5000 can also perform tests on rotating machines. Main features Fully automatic Variable output frequency: 1 – 500 Hz Output voltage up to 12 kV Tan Delta, capacitance, dissipation factor measurements and exciting current test RCTD – compensating reactor module allows increasing the test current and getting the maximum test voltage with high capacitive burdens PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Patented technology for capacitance and Tan Delta measurement Light and compact Tests performed Tangent Delta Capacitance
TAQ 2

TAQ 2

Wickelstromwandler - Wechselstromnetz - Primärstrom 5…80A - Bürde : 2…6VA - Klasse : 0,5 / 1 / 3 • Wickelstromwandler - Wechselstromnetz • Primärstrom 5…80A • Sekundärstrom 1A - 5A • Bürde : 2…6VA • Klasse : 0,5 / 1 / 3
TAQ 20

TAQ 20

Wickelstromwandler - Wechselstromnetz - Primärstrom 5…600A - Bürde : 20VA (Kl.0,5) - 40VA (Kl.1) • Wickelstromwandler - Wechselstromnetz • Primärstrom 5…600A • Sekundärstrom 1A - 5A • Bürde : 20VA (Kl.0,5) - 40VA (Kl.1) • Klasse : 0,5 / 1
TRA812

TRA812

Teilbarer Stromwandler - Wechselstromnetz - Bis 1500A - Primärschiene 80,5x120,5mm • Teilbarer Stromwandler - Wechselstromnetz • Primärschiene 80,5x120,5mm • Primärstrom : 500…1500A • Sekundärstrom : 1-5A • Bürde : : 3…15VA • Klasse : 0,5 / 1 / 3
TAS 125

TAS 125

Schienenstromwandler - Wechselstromnetz - Primärschiene 127x54mm - Primärstrom 400…4000A - Bürde : 3…200VA (MESSUNG) - 3…50VA (SCHUTZ) - Klasse : 0,5 / 1 (MESSUNG) - 5P5 • Schienenstromwandler - Wechselstromnetz • Primärschiene 127x54mm • Primärstrom 400…4000A • Sekundärstrom 1A - 5A • Bürde : 3…200VA (MESSUNG) - 3…50VA (SCHUTZ) • Klasse : 0,5 / 1 (MESSUNG) - 5P5 / 5P10 (SCHUTZ)
TRA 230

TRA 230

Teilbarer Stromwandler - Wechselstromnetz - Bis 400A - Primärschiene 20,5x30,5mm • Teilbarer Stromwandler - Wechselstromnetz • Primärschiene 20,5x30,5mm • Primärstrom : 60…400A • Sekundärstrom : 1-5A • Bürde : : 1…6VA • Klasse : 0,5 / 1 / 3
Hochdruck Testpumpe ADT919A

Hochdruck Testpumpe ADT919A

Erzeugung von 95% Vakuum bis 140 bar Druck Erzeugt 140 bar in 30 Sekunden Geringer Wartungsaufwand Handfeste Schnellanschlüsse Marktneuheit Die ADT919A Hochdruck Pumpe ist eine von Hand zu bedienende Pumpe für die Erzeugung von Drücken von 95% Vakuum bis 140 bar. Die Schraubenpresse wurde für die Feindruckjustage mit einer Auflösung bis zu 10 Pa (0,1 mbar) entwickelt. Das besonders entworfene Abschlussventil hält den Druck während der Kalibrierung so stabil wie möglich. Die zurückgebliebene Flüssigkeit vom Prüfling in der Pumpe wird gesammelt und dann werden der Entlüftung ausgestoßen. Die beiden handfesten Anschlüsse an der Pumpe ermöglichen das schnelle Anbringen und Abmontieren der Testpumpe ohne die Erforderlichkeit von PTFE Band oder Schraubenschlüsseln. Der ADT919A ist eine ideale Vergleichstestpumpe für die Kalibrierung von Druckgeräten. Hohe Leistungsfähigkeit Erzeugt 140 bar in 30 Sekunden. Benutzerdefinierbare Auflösung 10 Pa (0,1 mbar) Hohe Stabilität Das besonders entworfene Abschlussventil hält den Druck während der Kalibrierung so stabil wie möglich. Langlebig und geringer Wartungsaufwand Die interne Gas-Flüssigkeit-Isolation schützt die Pumpe vor Feuchtigkeit und Schmutz. Die zurückgebliebene Flüssigkeit vom Prüfling in der Pumpe wird gesammelt und dann werden der Entlüftung ausgestoßen. Nicht korrosives und verschleißbeständiges Material. Handfeste Schnellanschlüsse Ermöglichen das schnelle Anbringen und Abmontieren der Testpumpe ohne PTFE Band oder Schraubenschlüssel. Medium…………………………………………………………………………………………………………………………..Luft Erzeugter Druckbereich………………………………………………95% Vakuum bis 140 bar positiver Druck Auflösung…………………………………………………………………………………………………….10 Pa (0,1 mbar) Material Druckkolben/ Adapter……………………………………………………………………………………………………….SST Gehäuse………………………………………………………………………………………..SST/ Aluminum Abdichtung………………………………………………………………………………………………Buna-N Anschluss Handfeste Anschlüsse für Testmanometer und Referenzmanometer. Testmanometer Anschluss…………………………¼ NPT Buchse, ¼ BSP Buchse oder M20X1.5 Buchse Referenzmanometer Anschluss…………………..¼ NPT Buchse, ¼ BSP Buchse oder M20X1.5 Buchse Abmessungen……………………………………………………………………………..178 mm x 540 mm x 270 mm Gewicht……………………………………………………………………………………………………………………….6,5 kg Herstellergarantie………………………………………………………………………………………………………..1 Jahr
TA 221

TA 221

Aufsteckstromwandler - Ø 21 mm - Messung - Kl. 0,5 - 1 - 3 • Aufsteckstromwandler - Wechselstromnetz • Rundleiter und Primärschiene Ø 21mm - 20,5x10,5mm • Primärstrom 50...300A • Sekundärstrom 1A - 5A • Bürde : 1,5...10VA • Klasse : 0,5 / 1 / 3
TRA816

TRA816

Teilbarer Stromwandler - Wechselstromnetz - Bis 5000A - Primärschiene 80,5x160,5mm • Teilbarer Stromwandler - Wechselstromnetz • Primärschiene 80,5x160,5mm • Primärstrom : 2000…5000A • Sekundärstrom : 1-5A • Bürde : : 15…25VA • Klasse : 0,5 / 1
TRA580

TRA580

Teilbarer Stromwandler - Wechselstromnetz - Bis 1000A - Primärschiene 50,5x80,5mm • Teilbarer Stromwandler - Wechselstromnetz • Primärschiene 50,5x80,5mm • Primärstrom : 250…1000A • Sekundärstrom : 1-5A • Bürde : : 1…10VA • Klasse : 0,5 / 1
IHP220 – Prüfpumpe

IHP220 – Prüfpumpe

Prüfdruck max.: 100 bar Fördermenge max. : 15 cm3/Hub Plunger-Ø: 22 mm Kategorie: 1-stufig Gewicht : 14 kg Abmessungen (L x B x H): 438 x 318 x 520 mm
TAS 102

TAS 102

Schienenstromwandler - 38 x 102 - Messung - Kl. 0,5 - 1 • Schienenstromwandler - Wechselstromnetz • Primärschiene 38x102mm • Primärstrom 800…3000A • Sekundärstrom 1A - 5A • Bürde : 8...25VA • Klasse : 0,5 / 1 • Befestigung auf vertikale oder horizontale Schiene
TAIBB

TAIBB

Aufsteckstromwandler - Ø 21 mm - Messung - Kl. 0,5 - 1 - 3 • Aufsteckstromwandler - Wechselstromnetz • Rundleiter und Primärschiene Ø 21mm - 16x12,5mm • Primärstrom 40...300A • Sekundärstrom 1A - 5A • Bürde : 1...7,5VA • Klasse : 0,5 / 1 / 3
KAM Primary current injection testing

KAM Primary current injection testing

This substation testing device is designed to grant high current output when needed in substation commissioning activities. Main features High current output up to 7000 A Powerful output up to 35 kVA Modular design for easy transport Primary current injection testing Protection relay testing Low voltage breaker testing CT testing Heat runs Tests performed High current 6000 A CT ratio CT polarity
HT35Bm - HT35Bs

HT35Bm - HT35Bs

Gleichstrom - Halleffekt - Stromwandler - Ø 35 mm - 10 bis 100 A • Halleffekt-Messumformer : Messung von Gleichstrom oder pulsierendem Gleichstrom (Durchführung 35mm) • Stromeingang 10...100Acc (10 Bereiche einstellbar) • Ausgang : 0...20mA oder 4...20mA • Hilfsspannung HT35Bm: 24Vac - 20....60Vdc oder 80...270Vac - 110...300Vdc • Hilfsspannung HT35Bs: 15Vcc (entnommen von HT35Bm) • Isolation Eingang-Ausgang 4kV
ADT920 / 200 – Hochdruck Testpumpe

ADT920 / 200 – Hochdruck Testpumpe

Erzeugung von 95% Vakuum bis 200 bar Druck Erzeugt 200 bar in 40 Sekunden Geringer Wartungsaufwand Handfeste Schnellanschlüsse Marktneuheit Die ICP 920/200 Hochdruck Pumpe ist eine von Hand zu bedienende Pumpe für die Erzeugung von Drücken von 95% Vakuum bis 200 bar. Die Schraubenpresse wurde für die Feindruckjustage mit einer Auflösung bis zu 10 Pa (0,1 mbar) entwickelt. Mit dem langen Hebel können Drücke von 200 bar in 40 Sekunden erzeugt werden. Das besonders entworfene Abschlussventil hält den Druck während der Kalibrierung so stabil wie möglich. Die zurückgebliebene Flüssigkeit vom Prüfling in der Pumpe wird gesammelt und dann werden der Entlüftung ausgestoßen. Die beiden handfesten Anschlüsse an der Pumpe ermöglichen das schnelle Anbringen und Abmontieren der Testpumpe ohne die Erforderlichkeit von PTFE Band oder Schraubenschlüsseln. Der ICP 920/200 ist eine ideale Vergleichstestpumpe für die Kalibrierung von Druckgeräten. Funktionen Hohe Leistungsfähigkeit Erzeugt 200 bar in 40 Sekunden. Besonders entworfene Schraubenpresse für die Feindruckjustage. Benutzerdefinierbare Auflösung 10 Pa (0,1 mbar) Hohe Stabilität Das besonders entworfene Abschlussventil hält den Druck während der Kalibrierung so stabil wie möglich. Langlebig und geringer Wartungsaufwand Die interne Gas-Flüssigkeit-Isolation schützt die Pumpe vor Feuchtigkeit und Schmutz. Die zurückgebliebene Flüssigkeit vom Prüfling in der Pumpe wird gesammelt und dann werden der Entlüftung ausgestoßen. Nicht korrosives und verschleißbeständiges Material. Handfeste Schnellanschlüsse Ermöglichen das schnelle Anbringen und Abmontieren der Testpumpe ohne PTFE Band oder Schraubenschlüssel. Medium…………………………………………………………………………………………………………………………..Luft Erzeugter Druckbereich………………………………………………95% Vakuum bis 200 bar positiver Druck Auflösung…………………………………………………………………………………………………….10 Pa (0,1 mbar) Material Druckkolben/ Adapter……………………………………………………………………………………………………….SST Gehäuse………………………………………………………………………………………..SST/ Aluminum Abdichtung………………………………………………………………………………………Buna-N, F357 Anschluss Handfeste Anschlüsse für Testmanometer und Referenzmanometer. Testmanometer Anschluss…………………………¼ NPT Buchse, ¼ BSP Buchse oder M20X1.5 Buchse Referenzmanometer Anschluss…………………..¼ NPT Buchse, ¼ BSP Buchse oder M20X1.5 Buchse Abmessungen……………………………………………………………………………..178 mm x 540 mm x 270 mm Gewicht……………………………………………………………………………………………………………………….6,5 kg Herstellergarantie………………………………………………………………………………………………………..1 Jahr
Stoil Cell For dielectric oil test

Stoil Cell For dielectric oil test

Oil cell for the HV test of dielectric oil The option allows the testing of the insulation characteristics of the oil by checking if there is no contamination. Main features Maximum test voltage: 12 kV Cell volume: about 1l Capacitance of the empty cell: 60 pF. Tests performed Tangent Delta
HT80A

HT80A

Gleichstrom - Halleffekt - Stromwandler - Ø 80 mm - 400 bis 1000 A • Halleffekt-Messumformer : Messung von Gleichstrom oder pulsierendem Gleichstrom (Durchführung 80mm) • Eingang : bis 1000Adc • Ausgang : 0...10V oder 0...20mA / 4...20mA (einstellbar) • Hilfsspannung : 115Vac oder 230Vac oder 240Vac oder 20...150Vdc
CU-Ps Primary Current Injection Test Set

CU-Ps Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The CU-Ps primary current injection test set is ideally suited to commissioning and maintenance testing where very high currents are required. The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry, and is linked to the loading unit by control and metering cables. The control unit may be used with one of two loading units providing between 5000A or 6000A for 5 minutes or up to 10 or 12kA for short periods. Each loading unit has two outputs which may be connected in series or parallel for maximum flexibility. For example, the PLU-6k may be configured to either give a maximum current of 3000A at 6.6V or 6000A at 3.3V. The control and loading units are each housed in tough steel cases fitted with castors and protective lifting handles. The loading units have a small plan area to allow them to be positioned as close as possible to the test object, minimising power requirements and maximising the available current. The CU-Ps control unit is shown here with a PLU-6k loading unit. This combination may be used to inject currents of up to 6000A for 5 minutes or 12000A for 1 second. The CU-Ps primary current injection test set is ideally suited to all primary current injection tasks, including testing under and over current relays, circuit breakers and CT ratio testing. The control unit is rated at 20kVA and has digital metering. A memory facility is provided on the metering to hold the current reading when the output trips or is switched off. The current is automatically switched off when the device under test trips. The CU-Ps systems have a high accuracy timing system with 1ms resolution. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available for under and over current devices, reclosers, under and over voltage devices, current trips and circuit breakers. The AC output current is metered by a true RMS memory ammeter (acquisition time 20ms) with a liquid crystal display. The current metering has 3 ranges corresponding to 10%, 50% and 100% of the maximum rating of the loading unit. In addition, a 200% metering range is enabled in pulse mode for the 0.2s, 0.5s and 1s settings only. The CU-Ps systems have a flexible timing system with two contact inputs and 5 operating modes. Each contact circuit automatically selects for N/O or N/C contacts, and the status of each contact input is shown by an LED. The timing channels may also be triggered by a dc voltage between 24 and 240V. *Pulse mode applies current to the load for a maximum of the specified time. If contact set 1 changes state or the current drops below 20% of the metering range during the pulse time, the timer is stopped. The maximum output current is increased in pulse mode. The maximum obtainable current is set by the impedance of the test object and output leads. **Current operated mode is used to time circuit breakers with no auxiliary contacts. The timer is started when the current exceeds 20% of the selected metering range (e.g. 1000A on the PLU-5k 5000A range). The timer stops when the current falls. All test results from the CU-Ps can be stored in a USB memory key. The unit has a real-time clock to time and date-stamp all results. To log the results, first enter a comment for your results using the optional keyboard, and then select AUTO STORE. Whenever the timer stops, the time, current and all other parameters are added to a spreadsheet file on the USB key. You can then view the current set of results on the display or take the USB key out and open the file on your PC. All results are stored in a folder on the USB key named with the test date in a file named with the time. The CU-Ps primary current injection test sets and loading units are CE marked and are designed to meet the requirements of BS EN61010. The system is protected by electronic trips on the outputs, circuit breaker and fuse on the mains input, and a circuit breaker on the control unit output. The unit also has a duty cycle trip on the loading unit output and thermal protection. WEIGHT 115 kg DIMENSIONS 660 × 400 × 740 mm OPTIONAL ACCESSORIES A range of output lead sets are available to complement the CU-Ps system with current ratings between 3000A and 6000A. The leads are double insulated and have good flexibility. SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set
100ADM MK5 Secondary Current Injection Test Set

100ADM MK5 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100ADM mk5 Secondary Current Injection Test Set provides commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate. The 100ADM mk5 keeps the familiar user interface of previous models but adds a new metering system that accurately measures the RMS of a single cycle. It also features a new current limit mode to provide very fine control of very low currents, even into low impedance loads. Current limit mode also assists in testing self-powered overcurrent protection as fitted to many 11kV ring main units. The unit has a range of outputs allowing injection of currents as low as a few mA and as high as 100A. Voltages up to 240V are available on the main outputs, allowing high impedance current relays and voltage relays to be tested. Four true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety. The 100ADM Mk5 Secondary Current Injection Test Set is comprehensively protected by overcurrent, duty cycle and thermal trips, and keeps the user fully informed of any trip condition. A stabilised DC supply is provided to power the relay under test, along with an independently switched and isolated 110V AC output. The back-lit display on the 100ADM mk5 is bright and clear with a wide viewing angle. The results of a test can be seen here as they appear on the display A very flexible two channel timing system is provided, allowing trip times, reset times and re-close times to be quickly measured to a high degree of accuracy. The timer auto-ranges to measure from 1ms to 99999.9s. The 100ADM can be used to test many types of single phase secondary protection including: 27/59 Over and under voltage relays 37 Under current 51 IDMT relays 50/76 Instantaneous overcurrent 59G Neutral voltage displacement 79 Auto-reclosers 2 Time delay relays 51G/50G Earth fault relays 67 Directional overcurrent (basic tests) 52 Miniature circuit breakers Tripping relays Thermal relays 90V Voltage regulating relays WEIGHT 23.9 kg DIMENSIONS 560 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Mains lead Output lead set Spare fuses Carry strap OPTIONAL ACCESSORIES 100ADM-F, Part no. 006
T 1000 PLUS Secondary injection relay test set

T 1000 PLUS Secondary injection relay test set

Multi-tasking test set designed for testing relays and transducers Max current output: 250 A Max AC voltage output: 250 V Max DC voltage output: 300 V Frequency generator: 15 ÷ 550 Hz Phase angle shifter Battery simulator 20 ÷ 260 V DC Oscilloscope function for current and voltage USB port – Microprocessor controller Test results and settings saved into local memory TD 1000 Plus model with two current outputs and high power at 15 Hz. T1000 PLUS is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment. Tests performed Distribution relays Smart grid relays Single phase relays High burden relays
TAS 127B

TAS 127B

Schienenstromwandler - Wechselstromnetz - Primärschiene 54x127mm - Primärstrom 400…4000A - Bürde : 1…50VA - Klasse : 0,5 / 1 • Schienenstromwandler - Wechselstromnetz • Primärschiene 54x127mm • Primärstrom 400…4000A • Sekundärstrom 1A - 5A • Bürde : 1…50VA • Klasse : 0,5 / 1 • Befestigung auf vertikale oder horizontale Schiene
HTM - Hydrantentester

HTM - Hydrantentester

inkl. Standfüße, Batterie, Handbuch, Kalibrierzertifikat Nennweiten DN80 und DN100 • Durchflussmessbereich: 100-1500 l/min. bzw. 200 – 2500 l/min • Druck-Messbereich: 0-16 bar (0-10 bar; 0-6 bar) Anzeige am Manometer oder Datenlogger • Alu-Tragegriffe und Standfüsse mit Gummipuffer • Einlauf / Auslauf Beruhigungsstrecken 500 mm lang inkl. Standfüsse für einfachen Auf-/Abbau des Hydrantentesters • Digitalanzeige vor Ort für Durchfluss in l/min; bar; m³/h; m³ • Batteriebetrieb • Integrierter Datenlogger mit Impulsausgang bzw. 4-20 mA Ausgang für ext. Aufzeichnungsgerät / Datenlogger • Manometer; Digitalmanometer oder Drucksensoren mit 4-20 mA für ext. Aufzeichnungsgerät / Datenlogger
200ADM-P Secondary Current Injection Test Set

200ADM-P Secondary Current Injection Test Set

The 200ADM-P is a current injection system with a wide range of advanced features including phase shift, data storage and harmonic analysis. 0-200A output current True RMS metering with 1 cycle capture Variable auxiliary ac voltage/ current output with phase shift Auxiliary metering input V, f, Φ, Z, P, S, PF, CT ratio, harmonics & more Variable auxiliary output 12-220Vdc Multi-function auto-ranging timing system Current limit mode for fine control Data storage to USB memory key including waveform & harmonics USB keyboard/printer interface Automatic mains voltage selection The 200ADM-P Secondary Current Injection Test Set has a range of outputs allowing injection of currents between 1mA and 200A. Voltages up to 240V are available on the main outputs allowing high impedance current relays to be tested. True RMS metering with single cycle capture is provided. 4 current ranges allow the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used throughout for safe, reliable convenience. The 200ADM-P Secondary Current Injection Test Set has a flexible auxiliary ac output that can be used at up to 260V for voltage relays or up to 10A for current relays. The phase and frequency of this output are fully adjustable. This combination of voltage and current allows testing of relays that require two voltages, one voltage and one current or two currents. An auxiliary metering module is provided that meters ac and dc voltage, current and frequency from the auxiliary outputs or external signals. The module can also take measurements in conjunction with the main current output to meter phase angle, power, impedance, CT ratio and harmonics. A variable stabilised DC supply with current limit is provided to power the relay under test. WEIGHT 22.6 kg DIMENSIONS 500 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Output lead set Mains lead Sparefuses USB keyboard USB memory key Shoulder strap (except Pelicase unit) OPTIONAL ACCESSORIES 100ADM-F, Part no. 006 100AL Mk2 / Mk3, Part no. A199-0003
TAS 127

TAS 127

Schienenstromwandler - Wechselstromnetz - Primärschiene 38x127mm - Primärstrom 400…4000A - Bürde : 2…30VA - Klasse : 0,5 / 1 • Schienenstromwandler - Wechselstromnetz • Primärschiene 38x127mm • Primärstrom 400…4000A • Sekundärstrom 1A - 5A • Bürde : 2…30VA • Klasse : 0,5 / 1 • Befestigung auf vertikale oder horizontale Schiene
PCU1-SP MK2 Primary Current Injection Test Set

PCU1-SP MK2 Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The PCU1-SP mk2 is a medium powered primary current injection set offering output currents up to 5000A (11.5kVA for 40seconds). The system consists of a separate control unit containing all metering and control functions and a loading unit, such as the NLU200, NLU2000 or the NLU5000, that provides the high current output. The PCU1-SP mk2 are ideally suited to primary current injection, stability testing and circuit breaker testing. In addition, the SP version offers direct-reading CT ratio and polarity tests and a 100A secondary injection output. Two loading units are available, delivering a maximum output current of 2000A or 5000A. Each loading unit has three output taps to allow for a wide range of load impedances. For example, the NLU5000 may be configured to either give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V range or 1250A on the 9.2V range. *The above is an image of the PCU1-SP and Loading Unit The control unit is rated at 11.5kVA with a 2 second overload capability of 23kVA using pulse mode. All metering is digital and a memory facility is provided to hold the current reading when the output trips or is switched off. The current is switched by a solid state device and is automatically switched off when the device under test trips. The PCU1-SP systems have a high accuracy timing system, allowing timing tests to be carried out to a resolution of 1ms. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available to test under and over current devices, re-closers, under and over voltage devices, current trips and circuit breakers. A full range of high current output leads are available to complement the system in a range of lengths. WEIGHT 26 kg DIMENSIONS 450 × 275 × 305 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set OPTIONAL ACCESSORIES Trolley mounting system, Part no A204-0005 100ADM-F, Part no. 006 100AL MK2 / MK3 Lead Set, Part no. A199-0003
100A/E MK3 Secondary Current Injection Test Set

100A/E MK3 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100A/E mk3 secondary current injection test set has been designed to give the maintenance and commissioning engineer a large number of facilities in one self-contained instrument.The unit is portable, compact and simple to use. The mains supply for the unit is either 240V±10% or 115V +10% -6% at either 50 or 60Hz. Full load can be obtained at the supply voltage extremes. The current and voltage outputs are independently controlled and metered. The output current and voltage are displayed on large, clear panel instruments. An additional four range CT is provided, extending the ammeter range down to 0-100mA. All of the outputs are fully isolated by means of double wound transformers. The timing system on the 100A/E is very flexible, without compromising ease of use. Four modes of operation and two contact inputs are provided allowing for a wide range of events to be timed. Both contact inputs automatically select for normally open or normally closed contacts. Operation of the different timing modes is described overleaf. Internal start mode starts the timer when the ‘ON’ pushbutton is pressed, and stops the timer when the first contact set changes state. This mode is ideally suited to timing over-current relays. Single contact mode starts and stops the timer on the first and second changes of state of the first contact set, and dual contact mode starts the timer from the first set of contacts and stops it from the second set. These modes allow reset and re-close times of protective devices to be easily measured. The final mode of operation of the timer starts the timer when the current exceeds 20% of the selected metering range, and stops it when the current falls below 20%. This allows the timing of trips with no auxiliary contacts such as miniature circuit breakers. Automatic control has been provided such that all outputs can be switched off once the device under test has operated. The automatic control can be switched in or out of circuit for all outputs, enabling setting up procedures to be carried out. The instrument is housed in a robust case complete with a protective cover and fold-away carrying handles. The current output on the unit has eight ranges, allowing the selection of output voltages up to 150V and output currents up to 200A. The voltage output on the unit has three ranges, allowing the selection of output voltages up to 500Vac and 250VDC. If using a 100ADM-F with the 100A/E mk 3 unit you will need to to order A0006-0010 lead set. The output of the 100A/E mk3 secondary current injection test set is a true RMS analogue system with separate instruments for current and voltage. AC current is metered by a dual scaled ammeter reading 0-1A and 0-5A. AC voltage is metered by a dual scaled ammeter reading 0-300V and 0-600V. The output may be automatically switched off at the end of the test to safeguard the relay under test. This is available for both the voltage and current output. WEIGHT 33 kg DIMENSIONS 490 × 300 × 300 mm SUPPLIED ACCESSORIES Operating manual 2m Mains lead Non-latching contact lead 100AL lead set Spare fuses OPTIONAL ACCESSORIES 100ADM-F, Part no. 006 100A/E Filter, Part no. A0006-0010
DRTS 6 Automatic relay test set

DRTS 6 Automatic relay test set

Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 6×15 A (80 VA); 4×300 V (85 VA); 1×260 V DC High accuracy outputs: 0.1 %; 0.05% (HP) Analog measurement inputs IEC 61850 protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Tests performed Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters