Finden Sie schnell konfektioniert für Ihr Unternehmen: 1046 Ergebnisse

RE-2Y(St)H-TIMF&RE-2X(St)H-TIMF

RE-2Y(St)H-TIMF&RE-2X(St)H-TIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1RE-2Y(St)H-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)H-PIMF,MULTI-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2 Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2
RE-2Y(St)2YSWAY-fl

RE-2Y(St)2YSWAY-fl

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…) Triple: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
RE-Y(St)YSWAY-fl-TIMF & RE-Yw(St)YwSWAYw-fl-TIMF

RE-Y(St)YSWAY-fl-TIMF & RE-Yw(St)YwSWAYw-fl-TIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-TRIPLE, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 105oC heat resistant, RE-Yw(St)YwSWAYw-TIMF cables are suitable. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Inner sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 190 pF/m, 0,75 mm2 : max. 190 pF/m, 1,0 mm2 : max. 190 pF/m, 1,3 mm2 : max. 200 pF/m, 1,5 mm2 : max. 200 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2YCYSWAY-fl-PIMF

RE-2YCYSWAY-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, It can be manufacture as RE-2Y(St)CYSWAY-PIMF upon request. Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned Cu wires, 85% coverage Inner sheath: PVC compound, EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF

RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2YCY-fl

RE-2YCY-fl

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned Cu wires, 85% coverage Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)HSWAH & RE-2X(St)HSWAH

RE-2Y(St)HSWAH & RE-2X(St)HSWAH

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-TRIPLE, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
NHLSH -OZ

NHLSH -OZ

HALOGEN-FREE, CONTROL CABLES These halogen-free cables are used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines. These cables are used at covered areas, plants and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. These cables are not used for outdoor or underground installation. Conductor: Flexible copper wires, plain;, IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: HFFR compound, HI2 , VDE 0207-23 Core identification: According to TS/DIN EN 50334 black cores, with white numerals Lay-up: Cores laid up in layers of optimum pitch Separator: Polyester tape Outer sheath: HFFR compound, HM2, VDE 0207-24 Sheath colour: RAL 7001,Grey Standard: VDE 0245-201, (Designed according to) Insulation resistance: Min. 20 MΩ.km Rated voltage: 300 / 500V Test voltage: 2000 V Temperature range: Fixed: - 30 oC ~ + 70 oC, Mobile: - 5 oC ~ + 50 oC Min. bending radius: Fixed: 8 x D, Mobile: 15 x D Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Flame test: IEC 60332-3 & TS/DIN EN 50266-2-4
RE-2Y(St)YSWAY-fl & RE-2X(St)YSWAY-fl

RE-2Y(St)YSWAY-fl & RE-2X(St)YSWAY-fl

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)YSWAY-fl,SINGLE & MULTI-TRIPLE, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Inner sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Inner sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-Y(St)YSWAY-fl-MP

RE-Y(St)YSWAY-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED,ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: According to BS 5308 Part 2 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PVC compund, TM1, BS 7655, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 2 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF

RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-PIMF,SINGLE & MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOUR, LSZH SHEATHEDRE-2X(St)HSWAH-PIMF,SINGLE & MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED,ARMOUR, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / blue ; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Blackk Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-Y(St)YSWAY-fl & RE-Yw(St)YwSWAYw-fl

RE-Y(St)YSWAY-fl & RE-Yw(St)YwSWAYw-fl

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PVC INSULATED, COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Outer sheath (Y): PVC compound, 105 oC grade; EN 50290-2-22 Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Inner sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 190 pF/m, 0,75 mm2 : max. 190 pF/m, 1,0 mm2 : max. 190 pF/m, 1,3 mm2 : max. 200 pF/m, 1,5 mm2 : max. 200 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)HSWAH&RE-2X(St)HSWAH

RE-2Y(St)HSWAH&RE-2X(St)HSWAH

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-TRIPLE, XLPE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Note: Other core configurations manufactured upon request Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF

RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH-TIMF,MULTI-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / Beyaz / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
SIMH-FR/PF FE 180

SIMH-FR/PF FE 180

HIGH TEMPERATURE, TWISTED PAIR RESISTANT TO FIRE SILICONE CABLES These twisted pairs (pair form) cables fields of use as a control and power supply cable they are fire proof and halogen free cables which, on the basis of a fixed operating mode, can continue with the supply of a power for a period of 180 minutes under the existing fire conditions (at a temperature of 750OC and under the flames ). Also these cables shall satify EN50200 test which is a fire resistant with mechancal shock test (under the conditions at 842oC and mechenical shock) by the classes PH15-PH30-PH60-PH90, if it has requsted, Because of their unique features, they can be used; on the fire alarm systems, lighting systems on the equipment and devices which are connected to the fire alarm devices, in the environments which have no corrosive gases are emitted in the event of fire. These cables are used at metro, schools, airpots, hospitals, etc. Conductor: IEC 60228 Class 5, TS/DIN EN 60228 Class 5, Flexible copper wires, plain; Insulation: Speacial silicone rubber compound Core identification: According to TS HD 308 S2 & VDE 0293-308, Acc. to TS/DIN EN 50334 black cores with, white numerals with green/yellow after 5 cores Lay-up: Cores laid up in layers of optimum pitch Outer sheath: Silicone rubber compound Sheath colour: RAL 2009, Orange Standard: VDE 0250, DIN VDE 0282-15 and, TS HD 22.15 S1, (Designed according to) Insulation resistance: Min. 20 MΩ.km Temp. at conductor: + 180 oC Short circuit tempetarure: +200oC Rated voltage: 300 / 500V Test voltage: 2000 V Temperature range: Fixed: - 60 oC ~ + 180 oC, Mobile: - 25 oC ~ + 180 oC Min. bending radius: Fixed: 4 x D, Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1, IEC 60332-3 & EN 50266-2-4 Insulation integrity: IEC 60331 , VDE 0472-814 Fire resistant with mechanical shock*Upon request: DIN EN 50200 ; PH 15 (15 minutes), DIN EN 50200 ; PH 30 (30 minutes), DIN EN 50200 ; PH 60 (60 minutes), DIN EN 50200 ; PH 90 (90 minutes)
RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP

RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF

RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOUR, LSZH SHEATHEDRE-2X(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED,ARMOUR, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
SIMH-FR FE 180

SIMH-FR FE 180

HIGH TEMPERATURE, RESISTANT TO FIRE SILICONE CABLES These cables fields of use as a control and power supply cable they are fire proof and halogen free cables which, on the basis of a fixed operating mode, can continue with the supply of a power for a period of 180 minutes under the existing fire conditions (at a temperature of 750OC and under the flames ). Also these cables shall satify EN50200 test which is a fire resistant with mechancal shock test (under the conditions at 842oC and mechenical shock) by the classes PH15-PH30-PH60-PH90, if it has requsted, Because of their unique features, they can be used; on the fire alarm systems, on the equipment and devices which are connected to the fire alarm devices, in the environments which have no corrosive gases are emitted in the event of fire. These cables are used at schools, airpots, hospitals, etc. Conductor: IEC 60228 Class 5, TS/DIN EN 60228 Class 5, Flexible copper wires, plain; Insulation: Speacial silicone rubber compound Core identification: According to TS HD 308 S2 & VDE 0293-308, Acc. to TS/DIN EN 50334 black cores with, white numerals with green/yellow after 5 cores Lay-up: Cores laid up in layers of optimum pitch Outer sheath: Silicone rubber compound Sheath colour: RAL 2009, Orange Standard: VDE 0250, DIN VDE 0282-15 and, TS HD 22.15 S1, (Designed according to) Insulation resistance: Min. 20 MΩ.km Temp. at conductor: + 180 oC Short circuit tempetarure: +200oC Rated voltage: 300 / 500V ; 450/750 V ≥4,0 mm2 Test voltage: 2000 V ; 2500 V ≥4,0 mm2 Temperature range: Fixed: - 60 oC ~ + 180 oC, Mobile: - 25 oC ~ + 180 oC Min. bending radius: Fixed: 4 x D, Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1, IEC 60332-3 & EN 50266-2-4 Fire resistant with mechanical shock*Upon request: DIN EN 50200 ; PH 15 (15 minutes), DIN EN 50200 ; PH 30 (30 minutes), DIN EN 50200 ; PH 60 (60 minutes), DIN EN 50200 ; PH 90 (90 minutes) Insulation integrity: IEC 60331 , VDE 0472-814
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP

RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZH SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: According to BS 5308 Part 1 colour coded , Note: Other core configurations manufactured upon request Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
SIMH-SPEC

SIMH-SPEC

HIGH TEMPERATURE (300oC) RESISTANT SILICONE CABLES These silicone insulated cables are used as mobile connecting cables for equipment where high temperatures can arise as well as for ambient air temperature between –60oC and +300 oC. These cables have more resistance against tearing and tensile strength with its speacial formulated silicone compound. These cables are used in all areas of low mechanical load e.g in ship building, power plants, cooking plants, glass and ceramic works,foundaries ,cookies plants, solarium and sauna installations for high power lighting fixtures etc. Conductor: IEC 60228 Class 5, TS/DIN EN 60228 Class 5, Flexible copper wires, plain; Insulation: Speacial silicone rubber compound,300 oC grade Core identification: According to TS HD 308 S2 & VDE 0293-308, Acc. to TS/DIN EN 50334 black cores with, white numerals with green/yellow after 5 cores Lay-up: Cores laid up in layers of optimum pitch Outer sheath: Spea. silicone rubber compound,300 oC grade Sheath colour: RAL 3000, Red Standard: VDE 0250, DIN VDE 0282-15 and, TS HD 22.15 S1, (Designed according to) Insulation resistance: Min. 100 MΩ.km Temp. at conductor: + 300 oC Short circuit tempetarure: +360oC Rated voltage: 300 / 500V ; 450/750 V ≥4,0 mm2 Test voltage: 2000 V ; 2500 V ≥4,0 mm2 Temperature range: Fixed: - 60 oC ~ + 300 oC, Mobile: - 25 oC ~ + 250 oC Min. bending radius: Fixed: 4 x D, Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1, IEC 60332-3 & EN 50266-2-4 Insulation integrity: IEC 60331 , VDE 0472-814 a
Kabel, halogenfreie

Kabel, halogenfreie

Als Zulieferer der Industrie und des Handels sind wir ein innovativer und absolut zuverlässiger Hersteller von Netzanschlussleitungen, welche wir auf Kundenwunsch konfektionieren. Die harmonisierten PVC-Leitungen sowie alle weiteren Kabel werden am Firmenstandort in Trochtelfingen produziert. Unsere Herstellung von Netzanschlussleitungen ist bis ins Kleinste und darüber hinaus auch länderspezifisch diversifiziert. Standardzuleitungen werden generell in den gängigen RAL-Farben hergestellt. Bei der Herstellung von Netzanschlussleitungen unterscheiden wir beispielsweise in Netzstecker für die Schweiz und England. Und darüber hinaus bieten wir auch für USA, Australien, Italien, Argentinien sowie andere Länder an. Bei den europäischen Leitungen unterscheiden wir im 2-poligen Bereich in Euro-, Kleingeräte- und Konturenleitung, im 3-poligen Bereich in Kaltgeräte-, Warmgeräte- sowie Heißgeräteleitungen, wobei Warmgeräte mit Gummileitungen konfektioniert werden. Außerdem bieten wir verschiedene Verlängerungskabel, z.B. Kaltgeräteverlängerungen oder ein Schuko-Verlängerungskabel. Die Netzanschlussleitung verbindet das Endgerät mit der Steckdose. Zu unserem Portfolio als Hersteller von Netzanschlussleitungen gehören unterschiedliche Steckertypen, Gerätestecker und Gerätedosen, Sonderteile und Adapter oder auch Schutzkontakt-Steckdosen. Hinzu kommen noch vielfältige Kabeltüllen zur Durchführung der Zuleitung mit und ohne Knickschutz. Bei der Herstellung der Meterware werden die verdrillten Kupferlitzen durch Weich PVC isoliert. Eurostecker der Schutzklasse 2 haben eine PVC-Ummantelung und sind bis zu einer Belastung von 2,5 Ampere bei einer Spannung von 250 Volt verwendbar. Der internationale Standard für Stecker und Steckdosen IEC entspricht der deutschen DIN EN 60309. Sind Sie auf der Suche nach einem kompetenten Anbieter von Netzanschlussleitungen? Entscheiden Sie sich für die Produktvielfalt der Plastro Mayer GmbH und lassen sich jetzt direkt vom Kundenservice persönlich beraten.
Zuleitung “Export Argentinien”

Zuleitung “Export Argentinien”

Kaltgerätezuleitung “Export Argentinien” 1. Seite: angespritzter Argentinienstecker 2. Seite: angespritzte Zentralkaltgerätedose C13 1. Side: moulded on Argentinian plug 2. Side: moulded on straight “cold condition” connector C13 Kabeltypen/ Katalog-Nr. Cabletypes/ Catalogue-No. H05VV-F 3G1,00 gr/grey 2,50 m/ 0L06838
Zuleitung "Export USA Kanada"

Zuleitung "Export USA Kanada"

Zuleitung Export USA-Kanada 2-polig 1. Seite: angespritzter UL/CSA Stecker NEMA 1 15 nicht polarisiert 2. Seite: 30/EH Kabeltypen / Katalog-Nr. SPT2 2 x AWG18 sw/black 2,50 m 0L06800 SPT1 2 x AWG18 sw/black 2,50 m 0L06801 SVT 2 x AWG18/105 °C sw/black 2,00 m 0L06802 andere Längen und Farben auf Anfrage
Anschlussleitungen | Netzanschlussleitungen

Anschlussleitungen | Netzanschlussleitungen

Als Zulieferer der Industrie und des Handels sind wir ein innovativer und absolut zuverlässiger Hersteller von Netzanschlussleitungen, welche wir auf Kundenwunsch konfektionieren. Die harmonisierten PVC-Leitungen sowie alle weiteren Kabel werden am Firmenstandort in Trochtelfingen produziert. Unsere Herstellung von Netzanschlussleitungen ist bis ins Kleinste und darüber hinaus auch länderspezifisch diversifiziert. Standardzuleitungen werden generell in den gängigen RAL-Farben hergestellt. Bei der Herstellung von Netzanschlussleitungen unterscheiden wir beispielsweise in Netzstecker für die Schweiz und England. Und darüber hinaus bieten wir auch für USA, Australien, Italien, Argentinien sowie andere Länder an. Bei den europäischen Leitungen unterscheiden wir im 2-poligen Bereich in Euro-, Kleingeräte- und Konturenleitung, im 3-poligen Bereich in Kaltgeräte-, Warmgeräte- sowie Heißgeräteleitungen, wobei Warmgeräte mit Gummileitungen konfektioniert werden. Außerdem bieten wir verschiedene Verlängerungskabel, z.B. Kaltgeräteverlängerungen oder ein Schuko-Verlängerungskabel. Die Netzanschlussleitung verbindet das Endgerät mit der Steckdose. Zu unserem Portfolio als Hersteller von Netzanschlussleitungen gehören unterschiedliche Steckertypen, Gerätestecker und Gerätedosen, Sonderteile und Adapter oder auch Schutzkontakt-Steckdosen. Hinzu kommen noch vielfältige Kabeltüllen zur Durchführung der Zuleitung mit und ohne Knickschutz. Bei der Herstellung der Meterware werden die verdrillten Kupferlitzen durch Weich PVC isoliert. Eurostecker der Schutzklasse 2 haben eine PVC-Ummantelung und sind bis zu einer Belastung von 2,5 Ampere bei einer Spannung von 250 Volt verwendbar. Der internationale Standard für Stecker und Steckdosen IEC entspricht der deutschen DIN EN 60309. Sind Sie auf der Suche nach einem kompetenten Anbieter von Netzanschlussleitungen? Entscheiden Sie sich für die Produktvielfalt der Plastro Mayer GmbH und lassen sich jetzt direkt vom Kundenservice persönlich beraten.
Zuleitung “Export China”

Zuleitung “Export China”

Kaltgerätezuleitung “Export China” 1. Seite: angespritzter Chinastecker 2. Seite: angespritzte Zentralkaltgerätedose 10 A, 250 V, C13 1. Side: moulded on China plug 10 A 2. Side: moulded on straight “cold condition” connector 10 A, 250 V, C13 Kabeltypen/ Katalog-Nr. Cabletypes/ Catalogue-No. RVV 3G1,00 sw/black 3,00 m/ 0L06834 andere Ausführungen und Längen auf Anfrage further variations and lengths by request
GN 965 Montagesets für Profilsysteme 30 / 40 (Nutb

GN 965 Montagesets für Profilsysteme 30 / 40 (Nutb

Mit Montagsets GN 965 können verschiedene Normelemente an gängige Profilsysteme angebaut werden. Ein Set besteht jeweils aus einer Mutter für T-Nuten GN 506 und einer Schraube. EAN: 4045525904149 Artikelnummer: 965-8-M8-18-C Breite N: 8 Gewinde D: M 8 Länge L1 (Form C): 18
Zuleitung “Export Japan”

Zuleitung “Export Japan”

Kaltgerätezuleitung “Export Japan” 1. Seite: angespritzter Japanstecker 7-12-15 A, 125 V 2. Seite: angespritzte Zentralkaltgerätedose C13 1. Side: moulded on Japan plug 7-12-15 A, 125 V 2. Side: moulded on straight “cold condition” connector C13 Kabeltypen/ Katalog-Nr. Cabletypes/ Catalogue-No. VCTF 3 x 1,25 sw/black 2,50 m/ 0L06832 andere Längen und Farben auf Anfrage furhter lengths and colours by request auch mit 3-Stift-Stecker lieferbar also available with 3-pin-plug
Zuleitung “Export USA-Kanada”

Zuleitung “Export USA-Kanada”

Zuleitung “Export USA-Kanada” polarisiert 1. Seite: angespritzer UL/CSA-Stecker NEMA 5-15 2. Seite: 30/EH 1. Side: moulded on UL/CSA plug NEMA 5-15 2. Side: 30/endsplice Kabeltypen/ Katalog-Nr. Cabletypes/ Catalogue-No. SVT 3 x AWG18 sw/black 10 A 2,00 m/ 0L06810 SVT 3 x AWG18/105 °C sw/black 10 A 2,50 m/ 0L06811 SJT 3 x AWG18/105 °C sw/black 10 A 2,50 m/ 0L06812 SJT 3 x AWG18 sw/black 10 A 5,00 m/ 0L06816 SJT 3 x AWG16/105 °C sw/black 13 A 2,50 m/ 0L06814 SJT 3 x AWG16 sw/black 13 A 5,00 m/ 0L06817 SJT 3 x AWG14/105 °C sw/black 15 A 2,50 m/ 0L06815 Sjoow 3 x AWG16 sw/black 13 A 5,00 m/ 0L06818
Zuleitung “Export Australien”

Zuleitung “Export Australien”

1. Seite: angespritzter Australienstecker 2. Seite: angespritzte Zentralkaltgerätedose 10 A, 250 V, C13 1. Side: moulded on Australian plug 2. Side: moulded on straight “cold condition” connector 10 A, 250 V, C13 Kabeltypen/ Katalog-Nr. Cabletypes/ Catalogue-No. H05VV-F 3G1,00 sw/black 2,50 m/ 0L06870 andere Längen und Farben auf Anfrage further lengths and colours by request
Schnellmontage-Set Container

Schnellmontage-Set Container

Schnellmontage-Set Container EB 404 mm, mind. ET 530 mm, Alu-Finish 9081714 Schnellmontage Container-Set 404 x 530, Aluminium OptikSet besteht aus:• 1 Garnitur Stahleinstellseiten pulverbeschichtet schwarz• 1 Stück Zentralverschlusssystem Stop Control, vormontiert• 1 Garnitur Auszugsführung Quadro 12, Teilauszug, mit Silent System, vormontiert• 1 Garnitur Auszugsführung Quadro Duplex 25, Vollauszug, mit Silent System 40, vormontiert• 1 Garnitur Auszugsführung Quadro Duplex 45, Überauszug, mit Silent System 40, vormontiert• 1 Stück Schreibmaterialschale 40 mm• 1 Stück Stahlschubkasten• 1 Stück Stahlschubkasten mit Hängerahmen• 2 Stück Aktivatoren• 6 Stück Exzenterscheiben, inkl. 6 Stück Befestigungsschrauben • 1 Garnitur einstellbare Blendenstützen• 1 Stück Zylinderhebelschloss inklusive Innenzylinder• Montageanleitungen Artikelnummer: E9081714 Gewicht: 0.03 kg