Finden Sie schnell testem für Ihr Unternehmen: 575 Ergebnisse

100A/E MK3 Secondary Current Injection Test Set

100A/E MK3 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100A/E mk3 secondary current injection test set has been designed to give the maintenance and commissioning engineer a large number of facilities in one self-contained instrument.The unit is portable, compact and simple to use. The mains supply for the unit is either 240V±10% or 115V +10% -6% at either 50 or 60Hz. Full load can be obtained at the supply voltage extremes. The current and voltage outputs are independently controlled and metered. The output current and voltage are displayed on large, clear panel instruments. An additional four range CT is provided, extending the ammeter range down to 0-100mA. All of the outputs are fully isolated by means of double wound transformers. The timing system on the 100A/E is very flexible, without compromising ease of use. Four modes of operation and two contact inputs are provided allowing for a wide range of events to be timed. Both contact inputs automatically select for normally open or normally closed contacts. Operation of the different timing modes is described overleaf. Internal start mode starts the timer when the ‘ON’ pushbutton is pressed, and stops the timer when the first contact set changes state. This mode is ideally suited to timing over-current relays. Single contact mode starts and stops the timer on the first and second changes of state of the first contact set, and dual contact mode starts the timer from the first set of contacts and stops it from the second set. These modes allow reset and re-close times of protective devices to be easily measured. The final mode of operation of the timer starts the timer when the current exceeds 20% of the selected metering range, and stops it when the current falls below 20%. This allows the timing of trips with no auxiliary contacts such as miniature circuit breakers. Automatic control has been provided such that all outputs can be switched off once the device under test has operated. The automatic control can be switched in or out of circuit for all outputs, enabling setting up procedures to be carried out. The instrument is housed in a robust case complete with a protective cover and fold-away carrying handles. The current output on the unit has eight ranges, allowing the selection of output voltages up to 150V and output currents up to 200A. The voltage output on the unit has three ranges, allowing the selection of output voltages up to 500Vac and 250VDC. If using a 100ADM-F with the 100A/E mk 3 unit you will need to to order A0006-0010 lead set. The output of the 100A/E mk3 secondary current injection test set is a true RMS analogue system with separate instruments for current and voltage. AC current is metered by a dual scaled ammeter reading 0-1A and 0-5A. AC voltage is metered by a dual scaled ammeter reading 0-300V and 0-600V. The output may be automatically switched off at the end of the test to safeguard the relay under test. This is available for both the voltage and current output. WEIGHT 33 kg DIMENSIONS 490 × 300 × 300 mm SUPPLIED ACCESSORIES Operating manual 2m Mains lead Non-latching contact lead 100AL lead set Spare fuses OPTIONAL ACCESSORIES 100ADM-F, Part no. 006 100A/E Filter, Part no. A0006-0010
Hochfrequenz-Rütteltisch

Hochfrequenz-Rütteltisch

zur Herstellung von Betonprobekörper
Holo B12 Test für Zuhause

Holo B12 Test für Zuhause

Gesundheits- und Lifestyletests - einfach selbst von Zuhause durchführen. Messen Sie Ihr aktives Vitamin B12 mit dem blue balance® Holo-TC Test Aktives Vitamin B12 ist die Menge an Vitamin B12, die vom Körper sofort verwertet werden kann. Die Versorgung mit aktivem Vitamin B12 ist daher wichtig, um niedrige Werte oder sogar einen Mangel zu verhindern. Oft stellt sich heraus, dass der Gesamt-B12-Spiegel noch ausreichend ist, während der aktive B12-Wert bereits einen Mangel anzeigen kann. Haben Sie den Verdacht auf einen Vitamin B12-Mangel? Mit diesem aktiven Vitamin B12 Holo-TC-Test können Sie Ihren aktiven Vitamin B12-Spiegel überprüfen. - Bequem von zu Hause testen - Test auf aktiven Vitamin B12 Status - Klare und verständliche Ergebnisse - Ergebnis innerhalb von 6 Arbeitstagen nach Probeneingang - ISO15189 zertifiziertes europäisches Labor - Von klinischem Biochemiker und Arzt validiert
Corona-Schnelltest (Roche): SARS-CoV-2 Rapid Antigen-Test, Professional 1x25 Teste

Corona-Schnelltest (Roche): SARS-CoV-2 Rapid Antigen-Test, Professional 1x25 Teste

der SARS-CoV-2 Rapid Antigen Test von Roche ist ein immunchromatographischer Test fürden qualitativen Nachweis von spezifischen Antigenen im Nasopharynx Schnelle, zuverlässige Entscheidung am Point-of-Care: der SARS-CoV-2 Rapid Antigen Test von Roche ist ein immunchromatographischer Test fürden qualitativen Nachweis von spezifischen Antigenen im Nasopharynx. Dieser Test dient zum direkten Nachweis von Antigenen des SARS-CoV-2-Virus bei Personen mit Corona-Verdacht (COVID 19). - Schnelles Ergebnis (15-30 min), kein Folgetermin zur Besprechung der Testergebnisse erforderlich - Einfache Handhabung, keine zusätzlichen Materialien notwendig - Testmöglichkeit dort, wo keine Labortests zur Verfügung stehen - Test für den professionellen Gebrauch vorgesehen Testdurchführung in vier Schritten: - Abstrichnahme im Mund-Nasen-Raum durch medizinisches Fachpersonal - Probe wird durch Rotationsdrehung im Extraktionspuffer gelöst - Drei Tropfen der zu testenden Probe werden auf die vorgesehene Probenaufnahme gefüllt - Das Ergebnis kann nach 15 bis30 min abgelesen werden Sensivität: 96,52% Spezifität: 99,68% Kit-Ausstattung: - Teststreifen (einzeln in einem Folienbeutel mit Trockenmittel) - Extraktionspuffer - Spenderkappe - Folie (kann an Teststreifen angebracht werden, während einer Durchführung im Freien) -Gebrauchsanweisung - Kurzanweisung - Tupfer (Nasopharyngeal)
CoronavirusAg Rapid Test Cassette (Swab)

CoronavirusAg Rapid Test Cassette (Swab)

CoronavirusAg Rapid Test Cassette (Swab)
CO2 Monitor CEM DT-152D

CO2 Monitor CEM DT-152D

Das handliche CO2-Messgerät DT-152D eignet sich zum Überwachen der Luftqualität von Räumen, in denen sich Personen aufhalten. Eine hohe CO2-Konzentration beeinträchtigt die Konzentrationsfähigkeit und das Leistungsvermögen. Das handliche CO2-Messgerät DT-152D eignet sich zum Überwachen der Luftqualität von Räumen, in denen sich Personen aufhalten, wie z. B. Wohnungen, Hobbyräume, Partykeller, Schulräume/Klassenzimmer, Hörsäle, Kindergarten, Krankenhäuser, Büros, Produktionshallen sowie öffentliche Einrichtungen aller Art.
Clongene COVID-19 Antigen Rapid Test Cassette – 25er

Clongene COVID-19 Antigen Rapid Test Cassette – 25er

Die Lieferung erfolgt ausschließlich an Ärzten, Praxen, Behörden, Apotheken, Unternehmen mit Betriebsarzt oder Institutionen, die den Test durchführen dürfen. Dieser Clongene COVID-19 Schnelltest wurde bereits durch BfArM gelistet und durch Paul-Ehrlich-Institut evaluiert (weitere Information siehe Link, Test-ID: AT526/21) Das COVID-19 Antigen Rapid Test Cassette ist eine Lateral-Flow-Immunoassay-Methode zum qualitativen Nachweis von SARS-CoV-2-Nucleocapsid-Antigenen in Nasopharyngealabstrichen, Nasenabstrichen und Oropharynxabstrichen von Personen, bei denen der Verdacht von ihrem Gesundheitsdienstleister auf eine COVID-19-Infektion besteht. Die Ergebnisse werden verwendet, um das SARS-CoV-2-Nucleocapsid-Antigen zu identifizieren. Antigen ist allgemein in Nasopharyngealabstrichen, Nasenabstrichen und Oropharyngealabstrichen während der akuten Phase der Infektion nachweisbar. Merkmale: Vorliegen des Testergebnisses nach 15 Minuten 98,00 % Sensitivität 99,70 % Spezifität Lieferumfang: 25 Testkassetten 25 Extraktionsreagenzien 25 Sterile Tupfer 25 Extraktionsröhrchen 25 Pipettenspitzen Arbeitsstation Packungsbeilage Hinweis zur Lagerung: Im verpackten Beutel bei Temperatur (4-30 °C) verpackt lagern. 24 Monate haltbar. Bitte beachten Sie, dass dieser Schnelltest vom Rückgaberecht ausgeschlossen ist.
TELENOT

TELENOT

Einbruchmeldeanlagen, Alarmanlagen, Brandmeldeanlagen, Übertragungstechnik, Zutrittskontrolle Erleben Sie die Zukunft der modernen Gefahren- und Einbruchmeldetechnik. Mit der neuen Generation an Einbruch- und Gefahrenmelderzentralen hiplex eröffnet TELENOT eine neue Zeitrechnung. Mit einer Entwicklungsleistung von bislang 50 Mannjahren in den Bereichen Hard- und Software sowie Testing und dem damit größten Entwicklungsprojekt in der Firmengeschichte der TELENOT ELECTRONIC GMBH wird erstmals eine Zentrale auf den Markt der elektronischen sicherheitstechnik gebracht, die hinsichtlich - Flexibilität in der Systemarchitektur - Vielfältigkeit und Performance in den Anwendungen und - innovativer, graphischer Benutzeroberfläche zur Systemparametrierung den Maßstab für geprüfte und nachhaltige Sicherheitslösungen für alle Gebäudeanforderungen setzt. hiplex ist die technische Plattform, um in der Gegenwart und Zukunft durch verschiedenste Evolutionsstufen auf alle Anforderungen des Marktes reagieren zu können. Durch die dezentrale Prozessorstruktur lassen sich Signale und Meldungen nahezu gleichzeitig bearbeiten. Der bewährte com2BUS ist wesentlich erweitert.
Programmierbarer digitaler Controller zur präzisen Steuerung von Tests mit 10ns Schrittweite

Programmierbarer digitaler Controller zur präzisen Steuerung von Tests mit 10ns Schrittweite

In Testlaboren müssen parallel zu Messungen oftmals die Testanlage, das Testobjekt oder beides in einer bestimmten zeitlichen Abfolge angesteuert werden. Diese Aufgabe kann jetzt einfacher und flexibler als bisher mit dem SATURN Sequencer von AMOtronics gelöst werden. Die programmierbare digitale Steuereinheit ermöglicht es, Schalter, Leistungsschütze, Relais, IGBTs, MOSFETs und andere Komponenten hochpräzise und synchron anzusteuern. Der Sequencer bietet wahlweise 16, 32 oder 48 digitale Ein-/Ausgänge , welche in Gruppen zu 8 Anschlüssen wahlweise als BNC- oder Lichtwellenleiteranschlüsse ausgeführt werden können. Letztere bieten eine störungsresistente Isolierung gegen Hochspannung, Starkstrom und elektromagnetische Felder. Somit eignet sich das Gerät optimal als HV-Sequencer für Hochleistungs- und Hochspannungstests. Die optische Signalübertragung via Lichtwellenleiter ermöglicht außerdem auch die Überbrückung größerer Entfernungen zur Testanlage bzw. zum Testobjekt. Somit eignet sich der Sequencer auch für andere sicherheitskritische Anwendungen, wie beispielsweise Explosionsexperimente und Impaktversuche. Das Programm zur Steuerung der Sequencer-Ausgänge wird über eine komfortable grafische Bedienoberfläche in der mitgelieferten Software erstellt. Die Taktung erfolgt wahlweise mit 10ns über den internen hoch-präzisen Taktgeber oder synchron zu einem extern bereitgestellten Signal (z. B. Generatorfrequenzen von 16 2/3Hz, 50/60Hz, 400 Hz ... ). Neben einer rein sequentiellen Abarbeitung der Sequenzen werden auch Schleifen und Fallunterscheidungen (Verzweigungen) unterstützt. Nachdem das erstellte Programm auf den Onboard-FPGA (Field Programmable Gate Array) des Sequencers heruntergeladen wurde, wird es unabhängig vom Betriebssystem in Echtzeit abgearbeitet Der SATURN Sequencer steht wahlweise als eigenständiges Steuergerät oder als Ergänzungsmodul für SATURN Transientenrekorder zur Verfügung. Bei der letztgenannten Kombination können neben digitalen Eingängen auch die vom Transientenrekorder gemessenen analogen Signale überwacht werden. Auf diese Weise kann der Sequencer auf nahezu beliebige externe Ereignisse reagieren. Zusätzlich ermöglicht es diese Einsatzvariante, die ausgegebenen Steuersignale des Sequencers parallel zu den Messsignalen des Transientenrekorders aufzuzeichnen und beide anschließend im Detail zu analysieren und auszuwerten. Weitere Details auf der Produktseite des SATURN Sequencers...
TPT9000 Transformer Polarity Tester

TPT9000 Transformer Polarity Tester

Fast polarity testing of both voltage and current transformers. Compact and light Easy to use, plug & play Smart detection of incorrect connection Proving unit included in the kit as standard Fused lead sets included for user safety Supplied in a protective case. Long battery life Built in battery monitor The TPT9000 Transformer Polarity Tester is used for determining the correct polarity of current and voltage transformers. This device is a smart plug and play instrument designed for Commissioning Engineers. A lightweight instrument it comes with magnetised back panel, making it for storage on metallic walls or panels. TPT9000 automatically detects if the transformer has been connected incorrectly. The device comes with a proving unit to check the correct operation of the unit in the field. A set of 600V CAT IV fused test leads terminated in shrouded 4mm connectors is also included with the unit, along with 4 F500mA HRC fuses. The instrument is designed to be used on ‘dead’ systems (i.e., no externally supplied voltages are present on the test object). We strongly advise you not to connect the TPT9000 to a live system. Always make sure that the power of the device under test is off. TPT9000 Transformer Polarity Tester is designed for use in industrial and electrical substation environments on altitude level of maximum 2000m above sea level. Operating temperature is between 0°C and 45°C, while storage temperature is -20°C to 60°C. TPT9000 requires a single PP3 9V battery to operate. Battery level is automatically monitored, and the device will not perform a test if the battery voltage is below a useable level. WEIGHT 0.6 kg DIMENSIONS 118 × 79 × 32 mm SUPPLIED ACCESSORIES Proving unit 1 off 1m Black fused lead 1 off 1m Red fused lead 1 off 1m Blue fused lead 1 off 1m Brown fused lead Operating & Maintenance Manual Unit carry set case 9V battery OPTIONAL ACCESSORIES/SPARES Proving Unit, Part No. 249-0001 Complete replacement output lead set, Part No. A249-0002 Carry Case, Part No. A249-0003
200ADM-P Secondary Current Injection Test Set

200ADM-P Secondary Current Injection Test Set

The 200ADM-P is a current injection system with a wide range of advanced features including phase shift, data storage and harmonic analysis. 0-200A output current True RMS metering with 1 cycle capture Variable auxiliary ac voltage/ current output with phase shift Auxiliary metering input V, f, Φ, Z, P, S, PF, CT ratio, harmonics & more Variable auxiliary output 12-220Vdc Multi-function auto-ranging timing system Current limit mode for fine control Data storage to USB memory key including waveform & harmonics USB keyboard/printer interface Automatic mains voltage selection The 200ADM-P Secondary Current Injection Test Set has a range of outputs allowing injection of currents between 1mA and 200A. Voltages up to 240V are available on the main outputs allowing high impedance current relays to be tested. True RMS metering with single cycle capture is provided. 4 current ranges allow the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used throughout for safe, reliable convenience. The 200ADM-P Secondary Current Injection Test Set has a flexible auxiliary ac output that can be used at up to 260V for voltage relays or up to 10A for current relays. The phase and frequency of this output are fully adjustable. This combination of voltage and current allows testing of relays that require two voltages, one voltage and one current or two currents. An auxiliary metering module is provided that meters ac and dc voltage, current and frequency from the auxiliary outputs or external signals. The module can also take measurements in conjunction with the main current output to meter phase angle, power, impedance, CT ratio and harmonics. A variable stabilised DC supply with current limit is provided to power the relay under test. WEIGHT 22.6 kg DIMENSIONS 500 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Output lead set Mains lead Sparefuses USB keyboard USB memory key Shoulder strap (except Pelicase unit) OPTIONAL ACCESSORIES 100ADM-F, Part no. 006 100AL Mk2 / Mk3, Part no. A199-0003
18kV 10mA DC Tester PT18-10 MK2

18kV 10mA DC Tester PT18-10 MK2

Ultra lightweight (6.9kg) 1-200Adc test current with <2.5% ripple Supplied with standard 3m output lead set 0.1μΩ resolution mV, A, and m/μΩ displayed simultaneously USB memory key for data storage USB keyboard for comment entry Pre-settable test current with three buttons to store user test currents Large back-lit liquid crystal display Universal supply voltage 90-264V Optional current clamp to allows testing of objects with both sides earthed The PT18-10 mk2 high voltage dc test set is designed to perform tests on installed cable and jointing systems. The 18kV 10mA DC Tester has a variable output voltage with a maximum of ±18kVdc with a maximum charging capability of 10mA. A zero-volt interlock is fitted that prevents the output being switched on unless the output control is at zero. Units include an automatic load discharge system that discharges the cable under test when the output is switched off or a breakdown occurs. Internal dumping system can discharge a maximum of 2.5kJ on each output, corresponding to 10µF at 18kV. In the event of a test object failure, the overload circuit will automatically switch off the output voltage and earth the output via the internal discharge circuit. A DP20 discharge probe is supplied as standard with the PT18-10 mk2, 18kV 10mA DC Tester, allowing higher load capacitances to be safely discharged. The 18kV 10mA DC Tester has an internal fail-safe automatic discharge system with the following ratings: Max. discharge voltage (kVdc) 20kVdc Highest discharge energy 2.5kJ Highest discharge capacitance 10μF Max. discharges per hour 4 The automatic discharge switch is controlled by a solenoid. It may produce a noticeable hum when the HT output is energised. Output voltage is metered by two large, linear, analogue instruments marked 0-20kV. Meanwhile, current is metered by two further analogue instruments with 0-10 scale marking. The meters read 0-10mA directly, or 0-1mA when the ÷10 push button is operated. The HV output from the unit uses a high quality plug and socket system, allowing for easy cable replacement. High voltage plugs are protected in transit by plastic covers and are fully de-mountable. Screened 5 metre long high voltage output cables are provided with the equipment terminated with large clips. The mk2 units introduce automatic 115/230V mains voltage selection. That along the padded bag ensure maximum protection during transit.
TDX 5000 Tan Delta and capacitance test set

TDX 5000 Tan Delta and capacitance test set

TDX 5000 is developed as a compact solution for high voltage Capacitance and Tan Delta (Dissipation Factor) measurements. Using the reactor option, TDX 5000 can also perform tests on rotating machines. Main features Fully automatic Variable output frequency: 1 – 500 Hz Output voltage up to 12 kV Tan Delta, capacitance, dissipation factor measurements and exciting current test RCTD – compensating reactor module allows increasing the test current and getting the maximum test voltage with high capacitive burdens PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Patented technology for capacitance and Tan Delta measurement Light and compact Tests performed Tangent Delta Capacitance
100ADM MK5 Secondary Current Injection Test Set

100ADM MK5 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100ADM mk5 Secondary Current Injection Test Set provides commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate. The 100ADM mk5 keeps the familiar user interface of previous models but adds a new metering system that accurately measures the RMS of a single cycle. It also features a new current limit mode to provide very fine control of very low currents, even into low impedance loads. Current limit mode also assists in testing self-powered overcurrent protection as fitted to many 11kV ring main units. The unit has a range of outputs allowing injection of currents as low as a few mA and as high as 100A. Voltages up to 240V are available on the main outputs, allowing high impedance current relays and voltage relays to be tested. Four true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety. The 100ADM Mk5 Secondary Current Injection Test Set is comprehensively protected by overcurrent, duty cycle and thermal trips, and keeps the user fully informed of any trip condition. A stabilised DC supply is provided to power the relay under test, along with an independently switched and isolated 110V AC output. The back-lit display on the 100ADM mk5 is bright and clear with a wide viewing angle. The results of a test can be seen here as they appear on the display A very flexible two channel timing system is provided, allowing trip times, reset times and re-close times to be quickly measured to a high degree of accuracy. The timer auto-ranges to measure from 1ms to 99999.9s. The 100ADM can be used to test many types of single phase secondary protection including: 27/59 Over and under voltage relays 37 Under current 51 IDMT relays 50/76 Instantaneous overcurrent 59G Neutral voltage displacement 79 Auto-reclosers 2 Time delay relays 51G/50G Earth fault relays 67 Directional overcurrent (basic tests) 52 Miniature circuit breakers Tripping relays Thermal relays 90V Voltage regulating relays WEIGHT 23.9 kg DIMENSIONS 560 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Mains lead Output lead set Spare fuses Carry strap OPTIONAL ACCESSORIES 100ADM-F, Part no. 006
PCU1-SP MK2 Primary Current Injection Test Set

PCU1-SP MK2 Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The PCU1-SP mk2 is a medium powered primary current injection set offering output currents up to 5000A (11.5kVA for 40seconds). The system consists of a separate control unit containing all metering and control functions and a loading unit, such as the NLU200, NLU2000 or the NLU5000, that provides the high current output. The PCU1-SP mk2 are ideally suited to primary current injection, stability testing and circuit breaker testing. In addition, the SP version offers direct-reading CT ratio and polarity tests and a 100A secondary injection output. Two loading units are available, delivering a maximum output current of 2000A or 5000A. Each loading unit has three output taps to allow for a wide range of load impedances. For example, the NLU5000 may be configured to either give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V range or 1250A on the 9.2V range. *The above is an image of the PCU1-SP and Loading Unit The control unit is rated at 11.5kVA with a 2 second overload capability of 23kVA using pulse mode. All metering is digital and a memory facility is provided to hold the current reading when the output trips or is switched off. The current is switched by a solid state device and is automatically switched off when the device under test trips. The PCU1-SP systems have a high accuracy timing system, allowing timing tests to be carried out to a resolution of 1ms. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available to test under and over current devices, re-closers, under and over voltage devices, current trips and circuit breakers. A full range of high current output leads are available to complement the system in a range of lengths. WEIGHT 26 kg DIMENSIONS 450 × 275 × 305 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set OPTIONAL ACCESSORIES Trolley mounting system, Part no A204-0005 100ADM-F, Part no. 006 100AL MK2 / MK3 Lead Set, Part no. A199-0003
HV TROLLEY2 High Voltage AC Test System

HV TROLLEY2 High Voltage AC Test System

20kVA output capability 0-3kV to 0-15kV options available Accurate digital metering Key operated supply switch Dual overload protection Variable electronic trip 10-110% of rated output Voltage and current metering Optional 5s – 5min test timer External 24V interlock and zero-volt interlock Emergency stop switch The HV trolley2 series of units are high power AC flash test sets with a 20kVA output capability. Single Trolley Version The maximum output voltage can be customised to be any voltage up to 15kV. The unit is housed in a rugged aluminium enclosure with a cover to protect the control panel. It is mounted on wheels to allow easy movement within a production environment. The HV trolley2 is provided with accurate digital voltage and current metering and a variable electronic trip. An external interlock input is also fitted to the unit. Outputs are provided to drive 24V warning beacons. The HV output is connected to the test object by a high voltage cable 5m long.
T 1000 PLUS Secondary injection relay test set

T 1000 PLUS Secondary injection relay test set

Multi-tasking test set designed for testing relays and transducers Max current output: 250 A Max AC voltage output: 250 V Max DC voltage output: 300 V Frequency generator: 15 ÷ 550 Hz Phase angle shifter Battery simulator 20 ÷ 260 V DC Oscilloscope function for current and voltage USB port – Microprocessor controller Test results and settings saved into local memory TD 1000 Plus model with two current outputs and high power at 15 Hz. T1000 PLUS is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment. Tests performed Distribution relays Smart grid relays Single phase relays High burden relays
Stoil Cell For dielectric oil test

Stoil Cell For dielectric oil test

Oil cell for the HV test of dielectric oil The option allows the testing of the insulation characteristics of the oil by checking if there is no contamination. Main features Maximum test voltage: 12 kV Cell volume: about 1l Capacitance of the empty cell: 60 pF. Tests performed Tangent Delta
CU-Ps Primary Current Injection Test Set

CU-Ps Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The CU-Ps primary current injection test set is ideally suited to commissioning and maintenance testing where very high currents are required. The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry, and is linked to the loading unit by control and metering cables. The control unit may be used with one of two loading units providing between 5000A or 6000A for 5 minutes or up to 10 or 12kA for short periods. Each loading unit has two outputs which may be connected in series or parallel for maximum flexibility. For example, the PLU-6k may be configured to either give a maximum current of 3000A at 6.6V or 6000A at 3.3V. The control and loading units are each housed in tough steel cases fitted with castors and protective lifting handles. The loading units have a small plan area to allow them to be positioned as close as possible to the test object, minimising power requirements and maximising the available current. The CU-Ps control unit is shown here with a PLU-6k loading unit. This combination may be used to inject currents of up to 6000A for 5 minutes or 12000A for 1 second. The CU-Ps primary current injection test set is ideally suited to all primary current injection tasks, including testing under and over current relays, circuit breakers and CT ratio testing. The control unit is rated at 20kVA and has digital metering. A memory facility is provided on the metering to hold the current reading when the output trips or is switched off. The current is automatically switched off when the device under test trips. The CU-Ps systems have a high accuracy timing system with 1ms resolution. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available for under and over current devices, reclosers, under and over voltage devices, current trips and circuit breakers. The AC output current is metered by a true RMS memory ammeter (acquisition time 20ms) with a liquid crystal display. The current metering has 3 ranges corresponding to 10%, 50% and 100% of the maximum rating of the loading unit. In addition, a 200% metering range is enabled in pulse mode for the 0.2s, 0.5s and 1s settings only. The CU-Ps systems have a flexible timing system with two contact inputs and 5 operating modes. Each contact circuit automatically selects for N/O or N/C contacts, and the status of each contact input is shown by an LED. The timing channels may also be triggered by a dc voltage between 24 and 240V. *Pulse mode applies current to the load for a maximum of the specified time. If contact set 1 changes state or the current drops below 20% of the metering range during the pulse time, the timer is stopped. The maximum output current is increased in pulse mode. The maximum obtainable current is set by the impedance of the test object and output leads. **Current operated mode is used to time circuit breakers with no auxiliary contacts. The timer is started when the current exceeds 20% of the selected metering range (e.g. 1000A on the PLU-5k 5000A range). The timer stops when the current falls. All test results from the CU-Ps can be stored in a USB memory key. The unit has a real-time clock to time and date-stamp all results. To log the results, first enter a comment for your results using the optional keyboard, and then select AUTO STORE. Whenever the timer stops, the time, current and all other parameters are added to a spreadsheet file on the USB key. You can then view the current set of results on the display or take the USB key out and open the file on your PC. All results are stored in a folder on the USB key named with the test date in a file named with the time. The CU-Ps primary current injection test sets and loading units are CE marked and are designed to meet the requirements of BS EN61010. The system is protected by electronic trips on the outputs, circuit breaker and fuse on the mains input, and a circuit breaker on the control unit output. The unit also has a duty cycle trip on the loading unit output and thermal protection. WEIGHT 115 kg DIMENSIONS 660 × 400 × 740 mm OPTIONAL ACCESSORIES A range of output lead sets are available to complement the CU-Ps system with current ratings between 3000A and 6000A. The leads are double insulated and have good flexibility. SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set
Bump Tester und Gas Kalibrator

Bump Tester und Gas Kalibrator

Gesetzliche Vorschriften und die Notwendigkeit des täglichen Stoßprüfens erzeugen ein starkes Bedürfnis von Gastests. Gasdetektoren spielen eine wichtige Rolle für die Sicherheit von Menschen und Anlagen. Calibration Gas Description Ni-Br regulator Stainless steel regulator Non-reactive gases Suitable Suitable H2S Suitable Suitable SO2 Suitable Suitable NO Not recommended Suitable NO2 Not recommended Suitable Cl2 Not suitable Suitable NH3 Not suitable Suitable HCL Not suitable Suitable PH3 Not suitable Suitable SiH4 Not suitable Suitable HCN Not suitable Suitable
DRTS 6 Automatic relay test set

DRTS 6 Automatic relay test set

Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 6×15 A (80 VA); 4×300 V (85 VA); 1×260 V DC High accuracy outputs: 0.1 %; 0.05% (HP) Analog measurement inputs IEC 61850 protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Tests performed Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 3 PLUS Automatic relay test set

DRTS 3 PLUS Automatic relay test set

DRTS 3 PLUS power system simulator is designed to give the highest accuracy when testing and calibrating protective relays, energy meter, transducer and power quality devices. This diagnostic and calibration equipment is the perfect solution to perform automatic testing on protection devices. Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 3×15 A (100 VA); 4×300 V (85 VA); 1×260 V DC High accuracy: better than 0,05% Analog measurement inputs IEC 61850 communication Protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Lightweight Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters
T 3000 Primary current injection test set

T 3000 Primary current injection test set

T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers Main features Multi function primary test system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities 3000 V AC high-pot test Generates up to 800 A (option up to 4000A with high current booster) Microhmmeter function (option): up to 400A DC RS232 interface for pc connection Possibility to store test results in T 3000 local memory (up to 500 results) Compact and lightweight. Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side CT excitation curve CT knee voltage CT winding resistance Burden resistance VT ratio VT polarity VT burden secondary side PT ratio PT winding resistance Distribution relays Smart grid relays Single phase relays High burden relays CB operation time
STS 3000 LIGHT Multifunction substation test set

STS 3000 LIGHT Multifunction substation test set

STS 3000 light is a testing system designed to perform Tan Delta and capacitance measurement on CTs, VTs, Power Transformer and Circuit Breaker Main features Fully automatic Variable output frequency: 15 – 500 Hz Output voltage up to 12 kV Power dissipation factor test with the module TD 5000 ( voltage up to 12 kV) PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Compact and lightweight. Tests performed Tangent Delta Capacitance
STS 3000 LIGHT Multifunction substation test set

STS 3000 LIGHT Multifunction substation test set

STS 3000 light is a testing system designed to perform Tan Delta and capacitance measurement on CTs, VTs, Power Transformer and Circuit Breaker Main features Fully automatic Variable output frequency: 15 – 500 Hz Output voltage up to 12 kV Power dissipation factor test with the module TD 5000 ( voltage up to 12 kV) PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Compact and lightweight. Tests performed Tangent Delta Capacitance
20A DC booster Winding resistance test

20A DC booster Winding resistance test

Maximum output current: 20 A DC Maximum power on output sockets: 400 W Current output switch: controlled by STCS Current output amplitude: controlled by STS 5000 or STS 4000 The 20A DC STCS booster allows to perform resistance tests on a PT with a current up to 20 A DC. The option is used together with STS 5000 and STS 4000 and must be connected to STCS module.
Abriebprüfschiebe Böhme

Abriebprüfschiebe Böhme

Verschleißprüfung anorganischer und nichtmetallischer Werkstoffe gemäß DIN 52108
Ausbreittisch für Frischbeton gemäß EN 12350

Ausbreittisch für Frischbeton gemäß EN 12350

zur Konsistenzprüfung im Labor und/oder auf der Baustelle
Ähnliche Suchen