Finden Sie schnell test tester für Ihr Unternehmen: 432 Ergebnisse

STS 5000 Multifunction substation test set

STS 5000 Multifunction substation test set

STS 5000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid. Main features Fully automatic Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000 Variable output frequency: 15 – 500 Hz Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV) 2000 v AC high-pot test Local control by large color display PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report IEC 61850-9-2 communication protocol Patented technology for Capacitance and Tan Delta measurement USB interface and Ethernet interface for PC connection. Compact and lightweight Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side ALF ISF CT excitation curve CT knee voltage CT winding resistance burden resistance voltage withstand rogowski coil low power transformer CT IEC 61850-9 VT ratio VT polarity VT burden secondary side VT IEC 61850-9 PT ratio PT vector group PT winding resistance OLTC tap changer dynamic resistance; PT excitation current PT no load current PT short circuit impedance PT leakage reactance Micro-ohmmeter CB operation time
Spannungsprüfer HT70

Spannungsprüfer HT70

Berührungsloser Spannungsprüfer bis 1000V AC, mit Drehfeldrichtungsermittlung Der HT70 ist ein praktischer berührungsloser Spannungsprüfer in Stiftform, der auch zur Ermittlung der Drehfeldrichtung und der Phasenübereinstimmung geeignet ist. Die Anzeige erfolgt über farbige LED und einen akustischen Summer.
METRALINE VT SENSE / Berührungsloser Spannungsprüfer

METRALINE VT SENSE / Berührungsloser Spannungsprüfer

Berührungsloser Spannungsprüfer mit schlankem isolierten Mess-Sensor für eine schnelle und kontaktlose Spannungsindikation. Der METRALINE VT SENSE ermöglicht dank seines schlanken, isolierten Mess-Sensors eine schnelle und kontaktlose Spannungsindikation. Die Unterstützung durch Vibration, die Spannungsanzeige mittels roter LED und akustische Signale erleichtern die Überprüfung und Analyse der Spannung erheblich. Zusätzlich werden Drehfelder durch eine 4-farbige LED und Vibration erkannt. Mit seiner Zertifizierung für die Messkategorie CAT IV 1000 V ist dieses neue Gerät unverzichtbar für professionelle Elektrofachkräfte. Produkt-Highlights • Kontaktlose Spannungsidentifikation • Drehfelderkennung mittels 4-farbiger LED und Vibration • Anzeige von Spannungsfeldern mittels Vibration Ihre Vorteile • Nahtlose Integration in Ihre Arbeitsweise dank seiner benutzerfreundlichen Bedienung • Garantiert eine komfortable und sichere Spannungsprüfung • Überzeugt durch ein ausgezeichnetes Preis-Leistungsverhältnis Technische Merkmale • 20…1000 V bis 400 Hz • Spannungsanzeige durch rote LED, akustische Anzeige über integriertem Tongeber • Drehfelderkennung mittels 4-farbiger LED und Vibration • Anzeige von Magnetfeldern mittels gelber LED • Anzeige von Spannungsfeldern mittels Vibration • Ein-/Ausschalter mit optischer Anzeige • Auto Power Off • Integrierte Taschenlampe • Messkategorie CAT IV 1000 V
Elcometer Taber® 5135 & 5155 Rotationsabriebprüfgerät

Elcometer Taber® 5135 & 5155 Rotationsabriebprüfgerät

Dieses Gerät wird vorwiegend zum Prüfen von Keramik, Kunststoffen, Textilien, Metallen, Leder, Gummi, sowie farb-, lack- und galvanisch beschichteten Oberflächen verwendet. Beschleunigte Verschleißtestverfahren wurden auch in vielen internationalen Prüfnormen nach ASTM, ISO, TAPP und DIN sowie für Fertigungsverfahren im Automobilbau definiert. Das Taber Rotationsabriebprüfgerät hat sich als ein Industriestandard für die Verschleißfestigkeitsprüfung etabliert und ist wahlweise mit einem oder zwei Testköpfen zum gleichzeitigen Prüfen von zwei unterschiedlichen oder identischen Materialproben lieferbar. Eine große Auswahl an Reibrädern und -zubehör zur Simulation echter Verschleißbedingungen. Funktionsmerkmale: - Drehzahl 60 und 72 U/Min. - Ausgewuchtete, kalibrierte Arme und Radhalterungen - Vakuumsystem mit präziser Höhenverstellung - Versiegeltes Aluminiumgehäuse mit Membranbedienfeld und Digitalanzeige Beschreibung: Elcometer Taber® 5155 Abmessungen: 482 x 355 x 279 mm
Corona-Laientest, Selbsttest für Zuhause Joinstar 5 St. SARS-CoV-2 - Kurzer Nasenabstrich

Corona-Laientest, Selbsttest für Zuhause Joinstar 5 St. SARS-CoV-2 - Kurzer Nasenabstrich

HOHE SPEZIFITÄT (99,76 %) Corona - Laientest, Selbsttest für Zuhause Hohe Spezifität (99,2 %) Sensivität 96,10 % SARS-CoV-2 Antigen Schnelltest für minimal invasive Probenentnahme in der Nase. Neue Testgeneration: Kein Nasopharyngealabstrich (Nasen-Rachenabstrich) nötig! Eine Eindringtiefe von 2,5cm genügt Es handelt sich bei diesen Tests um jene, die auch in den Schulen verwendet werden! Schultest, daher besonders einfach und gut geeignet für die Selbstanwendung! In der Liste des Bundesinstituts für Arzneimittel und Medizinprodukte WHO Listung – für diagnostische SARS-COV-2 Tests Testergebnis innerhalb von 15 Minuten Lagertemperatur von 2 – 30°C Kein tiefer Nasopharyngealabstrich nötig, Probenentnahme aus dem vorderen Nasenraum genügt (ca. 2,5cm) 24 Monate haltbar, bitte beachten Sie auch den Aufdruck auf der Testkasette NEU: Laut Liste des BASG ist dieser Antigen Schnelltest von Hotgen auch zur Eigenanwendung geeignet! Hohe Zuverlässigkeit: Hohe Spezifität (100 %) Sensivität 98,50 % Wie funktioniert dieser Schnelltest? Antigen Schnelltests basieren auf dem Nachweis spezifischer Virus-Proteine. Das Coronavirus besitzt mehrere spezifische Proteine an seiner Oberfläche. Eines davon ist das Nukleokapsid Protein (N-Protein), welches dieser Test mittels chromatographischer Methode nachweisen kann. TECHNISCHE DATEN Der Joinstar COVID-19 Antigen-Schnelltest (Kolloidales Gold) ist zur Eigenanwendung durch Laien geeignet und dient zum qualitativen Nachweis neuartiger Coronaviren in Proben aus dem vorderen Nasenbereich. BfArM Sonderzulassung zur Eigenanwendung BfArM-Sonderzulassungsnummer: 5640-S-151/21 Vom Paul-Ehrlich-Institut evaluiert Sensitivität: 96,10% Spezifität: 99,20% Einzelne Pufferlösung bereits abgefüllt Empfindlich gegenüber verschiedenen Corona-Mutationen Eigenanwendung durch Laien zur Selbsttestung Laienanwendung Kurzer Nasenabstrich (2 - 2,5 cm) Leicht zu bedienen Kein abfüllen der Pufferlösung notwendig Testergebnis innerhalb von 15 Minuten Alle Testkomponenten sind enthalten Ergebnisse zeigen keine Kreuzreaktivität HIGHLIGHT Corona - Laientest, Selbsttest für Zuhause Hohe Spezifität (99,2 %) Sensivität 96,10 % Aktenzeichen der Sonderzulassung des BfArM: 5640-S-151/21 BfArM-AT-Nummer: AT236/20 Evaluiert vom Paul-Ehrlich-Institut (PEI) Erstattungsfähig Keine Kreuzreaktionen Leicht zu bedienen (Colloidal Gold Immunochromatography) Schnelle und zuverlässige Testergebnisse in nur 15 Minuten Abstrich im vorderen Nasenraum durchführbar Einfache Handhabung: Kein Röhrchen-Test Testlagerung bei Raumtemperatur Alle Testkomponenten sind enthalten Jeder Test in steriler Einzelverpackung LIEFERUMFANG 5x Nasenstäbchen 5x Testkassette 5x Behälter mit vorgefüllter Pufferlösung 1x Packungsbeilage (Deutsch) Der Test ist 1 Jahr haltbar nach Produktionsdatum, wenn alle Komponenten in dem versiegelten Beutel bleiben und der Test vor Licht geschützt bei 2°C bis 30°C aufbewahrt wird. Hersteller: Joinstar Biomedical Technology Co., Ltd., China EC REP: Lotus NL B.V., Niederlande Corona- Test Typ: Laientest, Selbsttest für Zuhause Test-Ergebnisse: Ca. 15 Minuten Spezifität: 99,2 % Sensivität: 96,10 % Aktenzeichen der Sonderzulassung des BfArM: 5640-S-151/21 BfArM-AT-Nummer: AT236/20
Rautiefen-Messgerät SRC

Rautiefen-Messgerät SRC

Rautiefen-Messgerät SRC gemäß EN DIN EN ISO 13473-1 Laser-Messverfahren für die Messung und Berechnung der Rautiefen Rt nach ZTV-ING., DAfStb-Rili SIB an allen Flächen (Decke, Wand, Boden, Schrägen etc.)
MedRhein TS20 – Clungene COVID-19 Antigen Rapid Test Cassette – Speichel/Spucktest (Profitest)

MedRhein TS20 – Clungene COVID-19 Antigen Rapid Test Cassette – Speichel/Spucktest (Profitest)

Clongene hat die COVID-19 Antigen-Schnelltestkasette (Speichel) entwickelt. Der COVID-19 Antigen-Schnelltest ist ein immunologischer Lateral-Flow-Test zur qualitativen Bestimmung von SARS-CoV-2-Nukleokapsid-Antigenen im Speichel und erkennt entsprechend der Stellungnahme vom 29.11.21 die Omikron Variante Download - BfArM gelistet AT114/21 (erstattungsfähig) - Evaluiert nach den Richtlinien des Paul-Ehrlich-Instituts - EU-RAT Liste Download - Hohe Spezifität - Sehr empfindlich bei hoher Viruslast - Einfach anzuwenden: Schnelle und zuverlässige Testergebnisse in nur 15 Minuten - Die Tests können mit Speichelproben (Spucktest, nicht-invasiv) durchgeführt werden - Kann bei Raumtemperatur aufbewahrt werden - Alle Testkomponenten, einschließlich sterilem Abstrichtupfer, sind enthalten ZERTIFIKATE | PRÜFBERICHTE BfArM gelistet: Download Ec-Konformitätserklärung: Download EU-RAT Liste:Download Nachweis mutierter Viren einschließlich des Delta-Stamm-Virus: Downlaod Technisches Datenblatt: Download Gebrauchsanweisung: Download Produktdatenblatt: Download BfArM gelistet AT114/21 (erstattungsfähig): ja Evaluiert nach den Richtlinien des Paul-Ehrlich-Instituts: ja Hohe Spezifität: ja Sehr empfindlich bei hoher Viruslast: ja Einfach anzuwenden: Schnelle und zuverlässige Testergebnisse in nur 15 Minuten: ja Die Tests können mit Speichelproben (Spucktest, nicht-invasiv) durchgeführt wer: ja Kann bei Raumtemperatur aufbewahrt werden: ja Alle Testkomponenten, einschließlich sterilem Abstrichtupfer, sind enthalten: ja
Maximeter

Maximeter

Robustes Qualitäts-Bandmaß im schwarz gummierten Gehäuse mit Edelstahlplakette. Dank Autostop-Technik bleibt das Stahlband an jedem Punkt stehen, ohne den Stopper betätigen zu müssen! Stabile nylonbeschichtete Stahlbänder mit starken Magnetwinkeln. Artikelnummer: 610829 Druckbereich: Ø=37 mm Gewicht: 123 g Maße: 70mm x 66mm x 35mm Zolltarifnummer: 90178010
Messtisch

Messtisch

Die Hildebrand Messtisch ist ein kostengünstiges und einfach zu bedienendes Gerät zur Bestimmung der Dicke für unterschiedliche Materialien. Für kundenspezifische Dickenmessungen können Sie die Messtische einzeln erwerben oder mit unterschiedlichen Messuhren, Gewichten und Messfüßen kombinieren. Durch die konsequente Verwendung von korrosionsbeständigen Materialien können die Messtische in Räumen mit hoher Luftfeuchtigkeit verwendet werden. Technische Daten Meßuhren 1075R: - Messweg: 12,5 mm - Auflösung 0,001 mm Messtisch: Granit: ∅200 mm x 40 mm Säulenführung: ∅30 mm (Edelstahl) Modell: HTG-A
Funksysteme

Funksysteme

Wir bieten eine umfassende, zuverlässige und erprobte Auswahl an HF-Sendern und -Empfängern für Breit- und Schmalband-Applikationen. Sender/Empfänger für: UHF, S-Band, L-Band digitale, analoge oder Videodaten Ausgangsleistung bis 10 W (Leistungsverstärker verfügbar) Optionen wie z.B. Subchannel auf Anfrage
TMG IO-Link Device Tool V5 - TS - Option FWUP

TMG IO-Link Device Tool V5 - TS - Option FWUP

Für die Entwicklung und Konformitätsprüfung von IO-Link Devices, die das Firmware Update Profile anbieten, bieten wir eine optionale Erweiterung für unser IO-Link Device Test System (TMG IO-Link Device Tool V5.1 - TS - Option FWUP) an. Es testet die komplette Funktionalität einschließlich der Teile, die der Firmware hinzugefügt werden müssen, sowie den Bootloader. Neben der Testsystem-Erweiterung bietet TMG TE auch die Firmware-Lösung für diese Funktionalität einschließlich des Firmware-Packagers an. Dieser verpackt die Firmware für den Einsatz in IO-Link-Tools und kann sie zum Schutz des geistigen Eigentums auch verschlüsseln. Das IO-Link Device Tool V5.1 - SE und PE unterstützt das Firmware-Update nicht nur mit dem TMG USB IO-Link Master V2 sondern auch mit vielen IO-Link Mastern verschiedener Hersteller. Die Windows DLL für den TMG USB IO-Link Master V2 wurde ebenfalls um das IO-Link Device Firmware Update erweitert. Technische Daten • Basierend auf TMG IO-Link Device Tool V5.1 – TS und dem darin enthaltenen TMG USB IO-Link Master V2 TS - Verfügbar als optionale Erweiterung - Die Lizenz wird auf den TMG USB IO-Link Master V2 TS übertragen - Hinweis: Alle TMG USB IO-Link Master V2 TS mit FW Rev 3.x können aktualisiert werden. Für Master mit FW Rev 2.x bieten wir ein kostengünstiges Hardware-Upgrade an • Testumfang: - IO-Link Device Firmware Update Protokoll Test - Testet das Protokollverhalten der Firmware und auch des Bootloaders
Twin Check 4.0 (IMPA Code: 652821)

Twin Check 4.0 (IMPA Code: 652821)

Elektronisches Wasser-in-Öl / BN Testgerät (Electronic Water-in-Oil / BN Test) For the Englisch version see below. Da das Unternehmen Innovationen auf den Markt der tragbaren Prüfgeräte einführen möchte und den Kunden smarte technische Lösungen zusammen mit der intelligenten logistischen Unterstützung und dem umfassenden Service anbieten kann, liefert der neue Twin Check 4.0 mehrere Upgrades einschließlich von bisher nicht verfügbaren Optionen. Das verbesserte Testgerät Twin Check 4.0 ist in einem modularen Design im Einklang mit dem Industrie 4.0-Konzept von Martechnic® entwickelt worden. Der besondere Aufbau des Gerätes ermöglicht einen flexiblen Ersatz jedes einzelnen Bestandteils (gesteckt oder geschraubt) und ermöglicht die Optimierung der Kosten. Die automatische digitale Messung von zwei kritischen Öl-Parametern, nämlich Wasser-in-Öl und Alkalitätsreserve (BN, ehemals TBN), Datenerfassung und Speicherung ermöglichen einfache und schnelle Tests und akkurate Testergebnisse. Mithilfe der USB-nach-Seriell-Verbindung können die Daten auf einen Computer für die Erstellung einer Trend-Grafik des Ölzustandes übertragen werden. Das benutzerfreundliche Navigationsmenü hilft das gesamte Testverfahren leicht und bequem durchzuführen. Merkmale: o Wasser-in-Öl • Messbereich: 0 – 1,0 vol. % H2O • Messzeit: abhängig vom Messwert (max. 20 Min.) • Toleranz: +/- 3 % o Basenzahl • Messbereich: 0 -150 BN • Messzeit: abhängig vom Messwert (max. 20 Min.) • Toleranz: +/- 1 BN Auch als Einzelprüfgerät erhältlich: Wasser-in-Öl oder BN Vorteile: • Anwendbar für alle Mineralöle • Verbessertes Design mit einem einfachen Navigationsmenü für hohe Messgenauigkeit • Interner Speicherchip mit der durchschnittlichen Datenspeicherung von 2,5 Jahren • Digitalanzeige der Testergebnisse • USB-nach-Seriell-Kabelanschluss für die Datenübertragung und Trendanalyse • Wasser-in-Öl-Messung: 6 Speicherplätze für bis zu 6 verschiedene Öltypen von unterschiedlichen Motoren • Ermittlung der Basenzahl: 6 Speicherplätze für bis zu 6 verschiedene Öltypen von unterschiedlichen Motoren • Wartung und Reparatur an Bord sind möglich The new test device Twin Check 4.0 was designed and developed with the aim to introduce innovations to the market of portable test equipment and to provide engineers and ship operators with intelligent technical solutions together with smart logistic support and comprehensive service. The Twin Check 4.0 offers several upgrades including previously not available options. The modified and improved Twin Check 4.0 is offered in modular design in accordance with the concept “Industry 4.0”. The special design of the device enables a flexible replacement of every single constituent part (plugged or screwed) and therefore provides cost optimization. The automatic digital measurement of two crucial oil parameters, namely water-in-oil and alkalinity reserve (BN, formerly TBN), automatic data recording and storing as well as easy and quick test procedures with accurate test results are among the advantages the Twin Check 4.0 provides its users. Through the USB to serial connection the collected data can be rapidly transferred to computer in order to create a trend graph of the oil condition. The user-friendly navigation menu helps to carry out the entire testing in an easy and comfortable way. Features: o Water-in-oil • Measuring range: 0 – 1.0 vol. % H2O • Measuring time: depends on the measured value (max. 20 min.) • Accuracy: +/- 3 % o Base Number • Measuring range: 0 -150 BN • Measuring time: depends on the measured value (max. 20 min) • Accuracy: +/- 1 BN Also available as single test unit: Water-in-Oil or BN Benefits: • Applicable for all mineral oil based fluids • Improved design with easy-to-follow navigation menu for high accuracy measurements • Internal memory chip with average data storage of 2.5 years • Digital read-out of test results • USB to serial cable connectivity for data transfer and trend analysis • Water-in-oil measurement: 6 modes for up to 6 various oil grades of different engines • BN determination: 6 modes for up to 6 various oil grades of different engines • Maintenance and repair on board is possible
Offshore-Geräte

Offshore-Geräte

Herstellung von Offshore-Geräten, Flachbaugruppen sowie Modulen und kompletten Geräten gemäß IPC-JSTD001 Kl.3. Von der Entwicklung bis zum Serienprodukt bietet die vbe Kamm GmbH alles aus einer Hand.
STS 5000 Multifunction substation test set

STS 5000 Multifunction substation test set

STS 5000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid. Main features Fully automatic Primary injection testing capabilities: up to 800 A or up to 5000 A / 7000 A, with the optional module BUX 5000 Variable output frequency: 15 – 500 Hz Power dissipation factor test with the optional module TD 5000 ( voltage up to 12 kV) 2000 v AC high-pot test Local control by large color display PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report IEC 61850-9-2 communication protocol Patented technology for Capacitance and Tan Delta measurement USB interface and Ethernet interface for PC connection. Compact and lightweight Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side ALF ISF CT excitation curve CT knee voltage CT winding resistance burden resistance voltage withstand rogowski coil low power transformer CT IEC 61850-9 VT ratio VT polarity VT burden secondary side VT IEC 61850-9 PT ratio PT vector group PT winding resistance OLTC tap changer dynamic resistance; PT excitation current PT no load current PT short circuit impedance PT leakage reactance Micro-ohmmeter CB operation time
100A/E MK3 Secondary Current Injection Test Set

100A/E MK3 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100A/E mk3 secondary current injection test set has been designed to give the maintenance and commissioning engineer a large number of facilities in one self-contained instrument.The unit is portable, compact and simple to use. The mains supply for the unit is either 240V±10% or 115V +10% -6% at either 50 or 60Hz. Full load can be obtained at the supply voltage extremes. The current and voltage outputs are independently controlled and metered. The output current and voltage are displayed on large, clear panel instruments. An additional four range CT is provided, extending the ammeter range down to 0-100mA. All of the outputs are fully isolated by means of double wound transformers. The timing system on the 100A/E is very flexible, without compromising ease of use. Four modes of operation and two contact inputs are provided allowing for a wide range of events to be timed. Both contact inputs automatically select for normally open or normally closed contacts. Operation of the different timing modes is described overleaf. Internal start mode starts the timer when the ‘ON’ pushbutton is pressed, and stops the timer when the first contact set changes state. This mode is ideally suited to timing over-current relays. Single contact mode starts and stops the timer on the first and second changes of state of the first contact set, and dual contact mode starts the timer from the first set of contacts and stops it from the second set. These modes allow reset and re-close times of protective devices to be easily measured. The final mode of operation of the timer starts the timer when the current exceeds 20% of the selected metering range, and stops it when the current falls below 20%. This allows the timing of trips with no auxiliary contacts such as miniature circuit breakers. Automatic control has been provided such that all outputs can be switched off once the device under test has operated. The automatic control can be switched in or out of circuit for all outputs, enabling setting up procedures to be carried out. The instrument is housed in a robust case complete with a protective cover and fold-away carrying handles. The current output on the unit has eight ranges, allowing the selection of output voltages up to 150V and output currents up to 200A. The voltage output on the unit has three ranges, allowing the selection of output voltages up to 500Vac and 250VDC. If using a 100ADM-F with the 100A/E mk 3 unit you will need to to order A0006-0010 lead set. The output of the 100A/E mk3 secondary current injection test set is a true RMS analogue system with separate instruments for current and voltage. AC current is metered by a dual scaled ammeter reading 0-1A and 0-5A. AC voltage is metered by a dual scaled ammeter reading 0-300V and 0-600V. The output may be automatically switched off at the end of the test to safeguard the relay under test. This is available for both the voltage and current output. WEIGHT 33 kg DIMENSIONS 490 × 300 × 300 mm SUPPLIED ACCESSORIES Operating manual 2m Mains lead Non-latching contact lead 100AL lead set Spare fuses OPTIONAL ACCESSORIES 100ADM-F, Part no. 006 100A/E Filter, Part no. A0006-0010
30kV 10mA DC Tester PT30-10 MK3

30kV 10mA DC Tester PT30-10 MK3

±30kVdc output voltage. 10mA output capability. Both voltage and current metered on HV outputs. Automatic earth system for dumping capacitive loads. HV output plug & socket system. Key operated supply switch to prevent unauthorised operation. Zero-volt interlock. Visual indication of test piece failure. Automatic mains voltage selection. The PT30-10 Mk3 high voltage dc test set is designed to perform tests on installed cable and jointing systems. The 30kV 10mA DC tester has a variable output voltage with a maximum of ±30kVdc, with a maximum charging capability of 10mA. A zero-volt interlock is fitted that prevents the output being switched on unless the output control is at zero. The units include an automatic load discharge system that discharges the cable under test when the output is switched off or a breakdown occurs. The internal dumping system can discharge a maximum of 2.5kJ on each output, corresponding to 4µF at 30kV. In the event of a test object failure, the overload circuit will automatically switch off the output voltage and earth the output via the internal discharge circuit. A manual DP40 discharge probe is also supplied as standard with the PT30-10 MK3, 30kV 10mA DC Tester, allowing higher load capacitances to be safely discharged. The mk2 units introduce automatic 115/230V mains voltage selection, allowing easy transition between site voltages. The output voltage is metered by two large, linear, analogue instruments marked 0-30kV. Test object current is metered by two further analogue instruments with 0-10 scale marking. The meters read 0-10mA directly, or 0-1mA when the ÷10 push button is operated. The HV output from the unit uses a high quality plug and socket system, allowing for easy cable replacement.
18kV 10mA DC Tester PT18-10 MK2

18kV 10mA DC Tester PT18-10 MK2

Ultra lightweight (6.9kg) 1-200Adc test current with <2.5% ripple Supplied with standard 3m output lead set 0.1μΩ resolution mV, A, and m/μΩ displayed simultaneously USB memory key for data storage USB keyboard for comment entry Pre-settable test current with three buttons to store user test currents Large back-lit liquid crystal display Universal supply voltage 90-264V Optional current clamp to allows testing of objects with both sides earthed The PT18-10 mk2 high voltage dc test set is designed to perform tests on installed cable and jointing systems. The 18kV 10mA DC Tester has a variable output voltage with a maximum of ±18kVdc with a maximum charging capability of 10mA. A zero-volt interlock is fitted that prevents the output being switched on unless the output control is at zero. Units include an automatic load discharge system that discharges the cable under test when the output is switched off or a breakdown occurs. Internal dumping system can discharge a maximum of 2.5kJ on each output, corresponding to 10µF at 18kV. In the event of a test object failure, the overload circuit will automatically switch off the output voltage and earth the output via the internal discharge circuit. A DP20 discharge probe is supplied as standard with the PT18-10 mk2, 18kV 10mA DC Tester, allowing higher load capacitances to be safely discharged. The 18kV 10mA DC Tester has an internal fail-safe automatic discharge system with the following ratings: Max. discharge voltage (kVdc) 20kVdc Highest discharge energy 2.5kJ Highest discharge capacitance 10μF Max. discharges per hour 4 The automatic discharge switch is controlled by a solenoid. It may produce a noticeable hum when the HT output is energised. Output voltage is metered by two large, linear, analogue instruments marked 0-20kV. Meanwhile, current is metered by two further analogue instruments with 0-10 scale marking. The meters read 0-10mA directly, or 0-1mA when the ÷10 push button is operated. The HV output from the unit uses a high quality plug and socket system, allowing for easy cable replacement. High voltage plugs are protected in transit by plastic covers and are fully de-mountable. Screened 5 metre long high voltage output cables are provided with the equipment terminated with large clips. The mk2 units introduce automatic 115/230V mains voltage selection. That along the padded bag ensure maximum protection during transit.
TD 5000 Tan delta test set

TD 5000 Tan delta test set

The high-voltage generator TD 5000 is a complementary module of STS serie. TD 5000 designed to perform Tan Delta measurements, dissipation factor and capacitance of transformer and bushing at the frequency of the mains or in a wide frequency range. Main features Optional module for STS 5000 and STS 4000 test set, standard module for STS 3000 light Tan Delta, capacitance, dissipation factor measurements and for exciting current test Output voltage from 12 V up to 12 kV Variable output frequency: 1 – 500 Hz PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report Compact and lightweight Patented technology Tests performed Tangent Delta Capacitance Dissipation factor
MultiSafe DSP HS11 zweipoliger Hochspannungsprüfer zur Prüfung von Gleich- und Wechselspannung

MultiSafe DSP HS11 zweipoliger Hochspannungsprüfer zur Prüfung von Gleich- und Wechselspannung

Der MultiSafe DSP HS11 ist ein zweipoliger Hochspannungsprüfer zur Prüfung von Gleich- und Wechselspannung an Umrichtern und Einspeisungen von Verkehrsbahnanlagen. Der Hochspannungsprüfer ist Ideal für die Prüfung von Zwischenkreisen von Umrichtern, Kondensatorbatterien und Einspeisungen von Verkehrsbahnanlagen. Durch vollautomatische Messabläufe werden Bedienfehler ausgeschlossen. Drei Anzeigesysteme garantieren gute Wahrnehmung in allen Umgebungen. Der MultiSafe stellt sich automatisch auf die zu prüfende Spannung AC / DC ein. Pluspunkte • präzise Anzeige von Spannungen von 50 bis 11 000 V AC / 16 000 V DC • Eigentest (R-Test) zur Überprüfung der Schutzwiderstände und der Elektronik  • höchste Sicherheit durch vergossene Schutzwiderstände • Stoßspannungsfest über 300 kV • leichte Bedienung, eindeutige Signale, beleuchtetes Display • robustes Gehäuse wasser- und staubdicht – IP 65 Technische Daten Nennspannungsbereich:50-11.000 V AC / 16.000 V DC Frequenzbereich:0-500 Hz Stromversorgung:9V – 6LR61 / 6LF22 Frequenzanzeige:Ja Eigentest:Ja Schutzart:IP 65
200ADM-P Secondary Current Injection Test Set

200ADM-P Secondary Current Injection Test Set

The 200ADM-P is a current injection system with a wide range of advanced features including phase shift, data storage and harmonic analysis. 0-200A output current True RMS metering with 1 cycle capture Variable auxiliary ac voltage/ current output with phase shift Auxiliary metering input V, f, Φ, Z, P, S, PF, CT ratio, harmonics & more Variable auxiliary output 12-220Vdc Multi-function auto-ranging timing system Current limit mode for fine control Data storage to USB memory key including waveform & harmonics USB keyboard/printer interface Automatic mains voltage selection The 200ADM-P Secondary Current Injection Test Set has a range of outputs allowing injection of currents between 1mA and 200A. Voltages up to 240V are available on the main outputs allowing high impedance current relays to be tested. True RMS metering with single cycle capture is provided. 4 current ranges allow the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used throughout for safe, reliable convenience. The 200ADM-P Secondary Current Injection Test Set has a flexible auxiliary ac output that can be used at up to 260V for voltage relays or up to 10A for current relays. The phase and frequency of this output are fully adjustable. This combination of voltage and current allows testing of relays that require two voltages, one voltage and one current or two currents. An auxiliary metering module is provided that meters ac and dc voltage, current and frequency from the auxiliary outputs or external signals. The module can also take measurements in conjunction with the main current output to meter phase angle, power, impedance, CT ratio and harmonics. A variable stabilised DC supply with current limit is provided to power the relay under test. WEIGHT 22.6 kg DIMENSIONS 500 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Output lead set Mains lead Sparefuses USB keyboard USB memory key Shoulder strap (except Pelicase unit) OPTIONAL ACCESSORIES 100ADM-F, Part no. 006 100AL Mk2 / Mk3, Part no. A199-0003
100ADM MK5 Secondary Current Injection Test Set

100ADM MK5 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100ADM mk5 Secondary Current Injection Test Set provides commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate. The 100ADM mk5 keeps the familiar user interface of previous models but adds a new metering system that accurately measures the RMS of a single cycle. It also features a new current limit mode to provide very fine control of very low currents, even into low impedance loads. Current limit mode also assists in testing self-powered overcurrent protection as fitted to many 11kV ring main units. The unit has a range of outputs allowing injection of currents as low as a few mA and as high as 100A. Voltages up to 240V are available on the main outputs, allowing high impedance current relays and voltage relays to be tested. Four true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety. The 100ADM Mk5 Secondary Current Injection Test Set is comprehensively protected by overcurrent, duty cycle and thermal trips, and keeps the user fully informed of any trip condition. A stabilised DC supply is provided to power the relay under test, along with an independently switched and isolated 110V AC output. The back-lit display on the 100ADM mk5 is bright and clear with a wide viewing angle. The results of a test can be seen here as they appear on the display A very flexible two channel timing system is provided, allowing trip times, reset times and re-close times to be quickly measured to a high degree of accuracy. The timer auto-ranges to measure from 1ms to 99999.9s. The 100ADM can be used to test many types of single phase secondary protection including: 27/59 Over and under voltage relays 37 Under current 51 IDMT relays 50/76 Instantaneous overcurrent 59G Neutral voltage displacement 79 Auto-reclosers 2 Time delay relays 51G/50G Earth fault relays 67 Directional overcurrent (basic tests) 52 Miniature circuit breakers Tripping relays Thermal relays 90V Voltage regulating relays WEIGHT 23.9 kg DIMENSIONS 560 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Mains lead Output lead set Spare fuses Carry strap OPTIONAL ACCESSORIES 100ADM-F, Part no. 006
TDX 5000 Tan Delta and capacitance test set

TDX 5000 Tan Delta and capacitance test set

TDX 5000 is developed as a compact solution for high voltage Capacitance and Tan Delta (Dissipation Factor) measurements. Using the reactor option, TDX 5000 can also perform tests on rotating machines. Main features Fully automatic Variable output frequency: 1 – 500 Hz Output voltage up to 12 kV Tan Delta, capacitance, dissipation factor measurements and exciting current test RCTD – compensating reactor module allows increasing the test current and getting the maximum test voltage with high capacitive burdens PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Patented technology for capacitance and Tan Delta measurement Light and compact Tests performed Tangent Delta Capacitance
T 1000 PLUS Secondary injection relay test set

T 1000 PLUS Secondary injection relay test set

Multi-tasking test set designed for testing relays and transducers Max current output: 250 A Max AC voltage output: 250 V Max DC voltage output: 300 V Frequency generator: 15 ÷ 550 Hz Phase angle shifter Battery simulator 20 ÷ 260 V DC Oscilloscope function for current and voltage USB port – Microprocessor controller Test results and settings saved into local memory TD 1000 Plus model with two current outputs and high power at 15 Hz. T1000 PLUS is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment. Tests performed Distribution relays Smart grid relays Single phase relays High burden relays
Bump Tester und Gas Kalibrator

Bump Tester und Gas Kalibrator

Gesetzliche Vorschriften und die Notwendigkeit des täglichen Stoßprüfens erzeugen ein starkes Bedürfnis von Gastests. Gasdetektoren spielen eine wichtige Rolle für die Sicherheit von Menschen und Anlagen. Calibration Gas Description Ni-Br regulator Stainless steel regulator Non-reactive gases Suitable Suitable H2S Suitable Suitable SO2 Suitable Suitable NO Not recommended Suitable NO2 Not recommended Suitable Cl2 Not suitable Suitable NH3 Not suitable Suitable HCL Not suitable Suitable PH3 Not suitable Suitable SiH4 Not suitable Suitable HCN Not suitable Suitable
Stoil Cell For dielectric oil test

Stoil Cell For dielectric oil test

Oil cell for the HV test of dielectric oil The option allows the testing of the insulation characteristics of the oil by checking if there is no contamination. Main features Maximum test voltage: 12 kV Cell volume: about 1l Capacitance of the empty cell: 60 pF. Tests performed Tangent Delta
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 6 Automatic relay test set

DRTS 6 Automatic relay test set

Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 6×15 A (80 VA); 4×300 V (85 VA); 1×260 V DC High accuracy outputs: 0.1 %; 0.05% (HP) Analog measurement inputs IEC 61850 protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Tests performed Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters
T 3000 Primary current injection test set

T 3000 Primary current injection test set

T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers Main features Multi function primary test system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities 3000 V AC high-pot test Generates up to 800 A (option up to 4000A with high current booster) Microhmmeter function (option): up to 400A DC RS232 interface for pc connection Possibility to store test results in T 3000 local memory (up to 500 results) Compact and lightweight. Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side CT excitation curve CT knee voltage CT winding resistance Burden resistance VT ratio VT polarity VT burden secondary side PT ratio PT winding resistance Distribution relays Smart grid relays Single phase relays High burden relays CB operation time
DRTS 3 PLUS Automatic relay test set

DRTS 3 PLUS Automatic relay test set

DRTS 3 PLUS power system simulator is designed to give the highest accuracy when testing and calibrating protective relays, energy meter, transducer and power quality devices. This diagnostic and calibration equipment is the perfect solution to perform automatic testing on protection devices. Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 3×15 A (100 VA); 4×300 V (85 VA); 1×260 V DC High accuracy: better than 0,05% Analog measurement inputs IEC 61850 communication Protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Lightweight Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters