Finden Sie schnell kabel vorkonfektioniert für Ihr Unternehmen: 567 Ergebnisse

RE-2Y(St)2YSWAY-fl-TIMF

RE-2Y(St)2YSWAY-fl-TIMF

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type 03 Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Two conductors twisted to a pair TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
Kabel mit Tragorganen für den Aufzugbau

Kabel mit Tragorganen für den Aufzugbau

Kabel mit Tragorganen (außen- und innenliegend) für den Aufzugbau: Personenaufzüge, Lastenaufzüge, Panoramaaufzüge. Im Bereich des Aufzugbaus und der Lifttechnik müssen für die Sicherheit der zu befördernden Personen und für die Zuverlässigkeit der Fördertechnik einige grundlegende Anforderungen erfüllt sein. Zum einen müssen die verwendeten Kabel starken mechanischen Belastungen standhalten. So sollten sie eine hohe Biegewechselfestigkeit aufweisen, denn gerade beim Einsatz in beispielsweise Bürogebäuden sind mehrere hunderte Fahrten pro Tag keine Seltenheit. Das bedeutet eine Dauerbelastung auch für die Kabeltechnik – und das über Jahre hinweg. Daher müssen die eingesetzten Kabel robust und verschleißfrei sein. Weiterhin: Hohe Anforderungen in Punkto Personensicherheit. Eine maßgebliche Rolle spielt hier u.a. der bauliche Brandschutz, die Auflagen sind hinsichtlich der zulässigen Materialien besonders streng. Zum anderen bedeutet das sichere Verkabeln von Fahrstühlen natürlich weit mehr, als nur die energetische Versorgung unter Einhaltung des Brandschutzes sicherzustellen.
BayEnergy®  NYY-O  0,6/1 kV  4-5-adrig

BayEnergy® NYY-O 0,6/1 kV 4-5-adrig

Starkstromkabel für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist (siehe DIN VDE 0298-1). Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist (siehe DIN VDE 0298-1). Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BaySpecial®  NYKY-J  0,6/1 kV  3 ¹/₂ - 4 ¹/₂

BaySpecial® NYKY-J 0,6/1 kV 3 ¹/₂ - 4 ¹/₂

Bleimantelkabel speziell für Anlagen, bei denen mit der Einwirkung von Lösungsmitteln, Treibstoffen, Ölen, Benzin oder dergleichen gerechnet werden muss (z.B. in Tankstellen). Im Außenbereich, im Erdreich, speziell in Anlagen, wenn mit der Einwirkung von Lösungsmitteln, Treibstoffen, Ölen, Benzin oder dergleichen gerechnet werden muss (z. B. in Raffinerien oder Tankstellen). Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Aufgrund des flammwidrigen Mantels könnte es in die Brandklasse Eca eingestuft werden.
BayEnergy® (N)2X(L)2Y  0,6/1 kV  3-adrig

BayEnergy® (N)2X(L)2Y 0,6/1 kV 3-adrig

Querwasserdichtes Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den Schichtenmantel querwasserdicht. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
Kabel für hohe Torsions- und Zugbeanspruchung, Robotik

Kabel für hohe Torsions- und Zugbeanspruchung, Robotik

Kabel für hohe Torsions- und Zugbeanspruchung, Robotik: Schweißroboter, Tauchroboter, Industrieroboter. Je nach Einsatzbereich und Funktion eines Roboters, muss die Verkabelung unterschiedlichste Anforderungen erfüllen. So müssen Kabel und Leitungen für Industrieroboter in der Regel starken mechanischen Beanspruchungen durch permanent gleiche Bewegungsabläufe standhalten. Bei Robotern für beispielsweise Schweiß- oder Unterwasserarbeiten sind zusätzliche Eigenschaften wie Hitzeresistenz oder absolute Wasserdichtheit gefordert. Je nachdem, wie viele Funktionalitäten ein Roboter haben soll, fällt auch der Leitungsumfang aus. So individuell, wie die Anforderungen hier sind, gibt es keine Lösungen von der Stange. Für die Robotik müssen Kabel und Leitungen grundsätzlich individuell, anwendungsbezogen und bedarfsgerecht konzipiert und entwickelt werden. Daher ermitteln unsere erfahrenen Experten vor der eigentlichen Realisierung gemeinsam mit Ihnen alle Anforderungen, Einsatzbedingungen und gegebenenfalls Sonderwünsche.
RE-2Y(St)YQY-fl

RE-2Y(St)YQY-fl

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, STEEL WIRE BRAIDED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the sheath, steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation.These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: PVC compound, EN 50290-2-22 Armour: Braid of galvanized steel wires, aprx. %85 cov. Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
3 in 1 Ladekabel REFLECTS-MONTIJA

3 in 1 Ladekabel REFLECTS-MONTIJA

Ein 3in1-Ladekabel mit Anschlüssen für Apple® und Android™ und alle Micro-USB-Geräte sowie USB-C. Auf dem Aluminiumgehäuse wirken Logos mit einer Lasergravur besonders hochwertig. Android ist eine Marke von Google Inc. Apple is a registered trademark of Apple Inc. Registered in the US and other countries Aluminium, silber, Polybeutel, USB 2.0, USB Typ C Artikelnummer: 1336403 Druckbereich: 14 x 23 Zolltarifnummer: 85444290 Gewicht: 20,4 g
Ölbeständiges Kabel

Ölbeständiges Kabel

Es ist geeignet für den Einsatz an Werkzeugmaschinen, Steuergeräten und Fließ- und Montagebändern. Anwendungsbereich : Dieses Tray Cable und Maschine-Tool Cable ist UV- und ölbeständig und zudem auch noch flexibel. Es ist geeignet für den Einsatz an Werkzeugmaschinen, Steuergeräten und Fließ- und Montagebändern. Produktvorteile : - Flexible Leitungen für den Einsatz als Tray Cable - ölbeständig - UV-Beständig - NFPA 79 für Industrieanlagen - WTTC Zulassung - WTTC: UL Subject 2277 - TC: UL Standard 1277 - (UL)/(cUL) approbiert
RE-Y(St)Y-fl-TIMF & RE-Yw(St)Yw-fl-TIM

RE-Y(St)Y-fl-TIMF & RE-Yw(St)Yw-fl-TIM

INSTRUMENTATION CABLES, EN 50288-7MULTİ-TRIPLE, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHED Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / White / Red; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 190 pF/m, 0,75 mm2 : max. 190 pF/m, 1,0 mm2 : max. 190 pF/m, 1,3 mm2 : max. 200 pF/m, 1,5 mm2 : max. 200 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)Y & RE-2X(St)Y

RE-2Y(St)Y & RE-2X(St)Y

INSTRUMENTATION CONTROL CABLES, EN 50288-7RE-2Y(St)Y,ÇOK DAMARLI, PE YALITIMLI, GENEL EKRANLI, PVC KILIFLIRE-2X(St)Y,ÇOK DAMARLI, XLPE YALITIMLI, GENEL EKRANLI, PVC KILIFLI These cables are used for control purposes (e.g. controlling of pumps, valves or engines) at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 90oC heat resistant, RE-2X(St)Y cables are suitable. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black cores numbered 1-2-3…, Other core configurations manufactured upon request. Lay-up: Cores laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Rated voltage: 500V Standard: TS/DIN EN 50288-7 Conductor resistance: 0,50mm2 : 36,0 Ω/km, 0,75mm2 : 24,5 Ω/km, 1,0mm2 : 18,1 Ω/km, 1,3mm2 : 13,9 Ω/km, 1,5mm2 : 12,1 Ω/km, 2,5mm2 : 7,4 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω, 2,5mm2 : 60 µH/Ω Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4
RE-Y(St)YSWAY-fl-MP

RE-Y(St)YSWAY-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED,ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: According to BS 5308 Part 2 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PVC compund, TM1, BS 7655, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 2 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
Zipper Ladekabel 2in1

Zipper Ladekabel 2in1

2 in1 Ladekabel USB auf MicroUSB und Lightning im Reißverschluss Design, Aufbewahrung ohne Verknoten, 50cm Artikelnummer: 1035834-0 Gewicht: 20g Maße: 1x50cm Verpackung: Polybeutel Verpackungseinheit: 1
Ladekabel HEJU Rake

Ladekabel HEJU Rake

So macht Laden Laune: Lightning-Kabel mit integriertem Micro- USB-Stecker. Komfortable Kabellänge von einem Meter – da zieht garantiert keiner mehr den Kürzeren. Artikelnummer: 1091026-1 Druckbereich: 10 x 10 mm Gewicht: 20 g Maße: 1000 x 14 x 7 mm Verpackung: Polybeutel
Zipper Ladekabel 2in1

Zipper Ladekabel 2in1

2 in1 Ladekabel USB auf MicroUSB und Lightning im Reißverschluss Design, Aufbewahrung ohne Verknoten, 50cm Artikelnummer: 1035834-7 Gewicht: 20g Maße: 1x50cm Verpackung: Polybeutel Verpackungseinheit: 1
BayEnergy® N2XY-O  0,6/1 kV  4-5-adrig

BayEnergy® N2XY-O 0,6/1 kV 4-5-adrig

Starkstromkabel für höhere Leitertemperaturen, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist. Im Innen- und Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
3 in 1 Ladekabel in Sonderform

3 in 1 Ladekabel in Sonderform

Handy Ladekabel 3 in 1 Ladekabel in Sonderform. Tolles Technik Gadget Ladekabel ca. 15 cm lang mit iPhone 5/6/7, Type C und Micro USB Anschluss. Kabel weiß, Sonderform 4C im Preis enthalten im PE-Beutel verpackt. 5 Volt, 1 Amp. Artikelnummer: 1336900 Gewicht: 60 g Maße: ca 150 - 180 mm Zolltarifnummer: 85444290
BayEnergy® N2XCWY  0,6/1 kV  3-adrig

BayEnergy® N2XCWY 0,6/1 kV 3-adrig

Starkstromkabel für höhere Leitertemperaturen zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
SIMH-FR/PF FE 180

SIMH-FR/PF FE 180

HIGH TEMPERATURE, TWISTED PAIR RESISTANT TO FIRE SILICONE CABLES These twisted pairs (pair form) cables fields of use as a control and power supply cable they are fire proof and halogen free cables which, on the basis of a fixed operating mode, can continue with the supply of a power for a period of 180 minutes under the existing fire conditions (at a temperature of 750OC and under the flames ). Also these cables shall satify EN50200 test which is a fire resistant with mechancal shock test (under the conditions at 842oC and mechenical shock) by the classes PH15-PH30-PH60-PH90, if it has requsted, Because of their unique features, they can be used; on the fire alarm systems, lighting systems on the equipment and devices which are connected to the fire alarm devices, in the environments which have no corrosive gases are emitted in the event of fire. These cables are used at metro, schools, airpots, hospitals, etc. Conductor: IEC 60228 Class 5, TS/DIN EN 60228 Class 5, Flexible copper wires, plain; Insulation: Speacial silicone rubber compound Core identification: According to TS HD 308 S2 & VDE 0293-308, Acc. to TS/DIN EN 50334 black cores with, white numerals with green/yellow after 5 cores Lay-up: Cores laid up in layers of optimum pitch Outer sheath: Silicone rubber compound Sheath colour: RAL 2009, Orange Standard: VDE 0250, DIN VDE 0282-15 and, TS HD 22.15 S1, (Designed according to) Insulation resistance: Min. 20 MΩ.km Temp. at conductor: + 180 oC Short circuit tempetarure: +200oC Rated voltage: 300 / 500V Test voltage: 2000 V Temperature range: Fixed: - 60 oC ~ + 180 oC, Mobile: - 25 oC ~ + 180 oC Min. bending radius: Fixed: 4 x D, Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1, IEC 60332-3 & EN 50266-2-4 Insulation integrity: IEC 60331 , VDE 0472-814 Fire resistant with mechanical shock*Upon request: DIN EN 50200 ; PH 15 (15 minutes), DIN EN 50200 ; PH 30 (30 minutes), DIN EN 50200 ; PH 60 (60 minutes), DIN EN 50200 ; PH 90 (90 minutes)
RE-2Y(St)Y-fl

RE-2Y(St)Y-fl

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…) Triple: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
Ladekabel 3 in 1 Leder Lisa - weiß

Ladekabel 3 in 1 Leder Lisa - weiß

Das elegante Leder Ladekabel Lisa verfügt über der verschiedene Anschlüsse (Lightning, Micro und Typ-C) und kann somit für jedes Mobiltelefon benutzt werden. Das Ladekabel hat eine reine Ladefunktion inkl. Keyring ideal für den Schlüsselanhänger Artikelnummer: 1345433 Breite: 65 Gewicht: 2g Höhe: 10 Kapazität: - Länge: 150 Maße: 65 x 150 x 10 mm
KABELKONFEKTION

KABELKONFEKTION

Wir konfektionieren Kabel passend Ihren Angaben und Vorschriften Individuelle Kabelkonfektion nach Ihren Anforderungen und den gesetzlichen Normen setzten wir in höchster Qualität um. Sie wählen aus mehr als 150 vorrätigen Kabelarten aus, wir verarbeiten diese mit modernsten Werkzeugen und Methoden. Wir bieten folgendes Leistungsspektrum an: - Konfektion von Einzeladern/Litzen, Flach- und Rundkabel, Sonderleitungen, Koaxialkabel, Motorenkabel, Steuer- und Signalleitungen - Konfektion kompletter Draht- und Kabelsätze (Querschnitten bis 120mm², weitere auf Anfrage) - Kundenspezifische Lieferung von Kabel- und Drahtsätze: Gebündelt, beschildert und nach Installationsprozess kommissioniert - Auslegung und Aufbauplanung mit Materialbeschaffung (gesamt oder teilweise) - Keine Lagerkosten durch Just-in-Time-Lieferung - Elektrische Prüfung aller Kabel mittels Testcomputer
Trommelbare Leitung

Trommelbare Leitung

für Verfahrgeschwindigkeiten bis 120m/min., extrem hohe Auf- und Abrollfestigkeit, geringer Außendurchmesser Anwendungsbereich : Die DR 720 P Highflex Leitung findet Verwendung für schwere Geräte wie Motorleitungstrommeln, Hebezeuge, Transportanlagen, fahrbare Motoren und landwirtschaftliche Geräte bei hohen mechanischen Beanspruchungen. Produktvorteile : - für Verfahrgeschwindigkeiten bis 120m/min. - extrem hohe Auf- und Abrollfestigkeit - geringer Außendurchmesser - geringes Leitungsgewicht - konform zur Niederspannungsrichtline 73/23/EWG CE
BayMotion®  Flex Power+  0,6/1 kV  3-5-adrig

BayMotion® Flex Power+ 0,6/1 kV 3-5-adrig

Hochflexible, halogenfreie, flammwidrige, UV- und witterungsbeständige, erdverlegbare Anschlussleitung mit einer sehr temperaturbeständigen Leiterisolierung aus einer speziellen HP Elastomermischung. BayMotion® CPR Eca Flex Power + ist eine hochflexible, halogenfreie, flammwidrige, UV- und witterungsbeständige, erdverlegbare Anschlussleitung mit einer sehr temperaturbeständigen Leiterisolierung aus einer speziellen HP Elastomermischung für den Einsatz im Anlagen- und Maschinenbau. Die Leitung ist ölbeständig und garantiert eine lange Lebensdauer in belasteter Umgebung, z. B. bei Anschlüssen von Transformatoren. universell einsetzbar, zur festen Verlegung in trockenen und feuchten Räumen, im Freien und direkt in Erde Einfache Montage durch hochflexible Ader Temperaturbeständige Leiterisolierung für erhöhte Strombelastbarkeit Optional auch für 1,8/3 kV erhältlich *) im Dreieck mit Berührung angeordnet. Die Anforderungen der Strombelastbarkeit nach VDE 0276-603 Teil 5G beachten.
Ladekabel HEJU Swing Micro

Ladekabel HEJU Swing Micro

Das Kabel passend zum beliebten USB Stick Swing mit Micro USB Anschluss Artikelnummer: 547923-3 Druckbereich: 12 x 6 mm Gewicht: 5 g Maße: 67 x 12 x 5.5 mm Verpackung: Kartonbox mit Fenster
Koaxialkabel

Koaxialkabel

LEONI verfügt über die aufwendigen Extrusionsanlagen für die exakte physikalische Verzellung von Polyethylen (PE), bei der das Dielektrikum präzise mit Stickstoffgas geschäumt wird. Wir zählen zu den wenigen Kabelherstellern, die mittels Bandiertechnologie Dielektrika aus expandiertem Polytetrafluorethylen (ePTFE) mit einer Dielektrizitätskonstante von bis zu 1,3 und herausragenden mechanischen Eigenschaften herstellen können.
BayEnergy® (N)2X(L)2Y  0,6/1 kV  vieladrig

BayEnergy® (N)2X(L)2Y 0,6/1 kV vieladrig

Querwasserdichtes Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den Schichtenmantel querwasserdicht. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
Signalkabel

Signalkabel

PUR-Kabel mit Binderstecker Serie 712 und D-SUB .
Heavy Equipment Steckverbinder AT, ATM, DT

Heavy Equipment Steckverbinder AT, ATM, DT

CONEC DT Steckverbinder, 2- bis 12-pol, mit/ohne Schutzbeschaltung, Stecker, Buchse, CONEC Superseal-Serie 2- bis 4-pol. Ob Traktoren, Bagger oder schwere Baumaschinen, das Segment IVCM (Industrial Vehicles and Construction Machines) stellt hohe Ansprüche an die eingesetzten Ventilsteckverbinder. Die von CONEC entwickelte umspritze Variante der DT-Steckverbinderserie bieten optimalen Schutz auch in schwierigsten Einsatzfeldern wie zum Beispiel Untertage, bei Minustemperaturen oder in staubigen, heißen Umgebungen. Die DT-Steckverbinderserie ist als Kabel zu Kabelverbindung ausgelegt und diese verrastet und verriegelt sicher über einen Latch mit dem Gegenstecker. Zur Entriegelung muss der Latch niedergedrückt werden, somit kann eine schnelle und sichere IP67 dichte Verbindung hergestellt werden. Optional ist die umspritzte DT-Steckverbinderserie mit einer LED zur Signalzustandsanzeige und Schutzbeschaltung ausgeführt. Einzigartig dabei ist die 360° Sichtbarkeit der LED Anzeige. Die Schutzbeschaltung hält Schalt- und Störspannung von der LED und nachgeschalteten Systemen fern. Um das Anschlusskabel in rauen Umgebungen zusätzlich zu schützen, ist die Umspritzung in der CONEC typischen Form ausgeführt und bietet die Möglichkeit, einen Schutzschlauch mit z.B. Kabelbinder zu befestigen. Optional wird eine Umspritzung mit einem angespritzten M12 Gewinde angeboten. So kann der Schutzschlauch direkt über eine M12 Mutter an der Umspritzung befestigt werden. Die vorhandenen Befestigungsoptionen sind ohne Einschränkung einsetzbar. Polzahl DT-Serie: 2-, 3-, 4-, 6-, 8-, 12-pol. Polzahl Superseal-Serie: 2-, 3-, 4-pol. Typ: Stecker, Kupplungsgehäuse Schutzart: IP67/IP69K
BayEnergy® N2XY-J  0,6/1 kV  1-adrig

BayEnergy® N2XY-J 0,6/1 kV 1-adrig

Starkstromkabel für höhere Leitertemperaturen, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist. Im Innen- und Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.