Finden Sie schnell kabel vorkonfektioniert für Ihr Unternehmen: 124 Ergebnisse

RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP

RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZH SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: According to BS 5308 Part 1 colour coded , Note: Other core configurations manufactured upon request Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
Einbaufertige Komponenten

Einbaufertige Komponenten

Unsere einbaufertigen Komponenten sind zur direkten Installation konzipiert und bieten eine schnelle und einfache Lösung für Ihre Projekte. Alle Bestandteile wie Stecker und Kontakte werden sorgfältig erfasst und dokumentiert, um eine reibungslose Integration zu gewährleisten. Diese Komponenten sind ideal für Anwendungen, die eine schnelle und zuverlässige Installation erfordern.
RE-Y(St)Y-fl-TIMF & RE-Yw(St)Yw-fl-TIMF

RE-Y(St)Y-fl-TIMF & RE-Yw(St)Yw-fl-TIMF

INSTRUMENTATION CABLES, EN 50288-7MULTİ-TRIPLE, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 105oC heat resistant, RE-Yw(St)Yw-TIMF cables are suitable. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / Blue / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / Blue / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Standard: TS/DIN EN 50288-7 Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 160 pF/mr, 0,75 mm2 : max. 160 pF/m, 1,0 mm2 : max. 160 pF/m, 1,3 mm2 : max. 170 pF/m, 1,5 mm2 : max. 170 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
Konfektionierung von Kabelbäumen

Konfektionierung von Kabelbäumen

Ein Kabelbaum besteht aus einer Reihe von Adern oder Litzen, die nicht wie beim einfachen Kabel nur 2 Stecker miteinander verbinden, sondern eine größere Anzahl. Ein Verbindungskabel für 3 Stecker wird meist als Y-Kabel bezeichnet. Beim eigentlichen Kabelbaum werden meist Adern verschiedener Länge und teilweise verschiedener Stärken miteinander gebündelt. Je nach Anwendung werden diese oft auch noch in ein gemeinsames Schutzrohr oder einen Schutzschlauch eingezogen oder mit Schrumpfschlauch überzogen. Als Steckverbinder kommt im Prinzip das gesamte Spektrum der elektrischen Verbindungstechnik in Frage. Kabelbäume werden beim Kabelkonfektionär einbaufertig konfektioniert. Dadurch fallen am Einbauort keine Konfektionsarbeiten mehr an und es können übliche Kabelbearbeitungsmaschinen zumindest für einige Arbeitsschritte verwendet werden. Typische Einbauorte von Kabelbäumen sind oft räumlich beengt und vom Monteur nur in unbequemer Haltung zu erreichen. Dort vor Ort Einzelkabel zu verlegen wäre fehlerträchtig und würde oft mehr Platz und vor allem mehr Handarbeit benötigen. Der fertige Kabelbaum erlaubt durch seine Form und Steifigkeit meist nur eine einzige Einbaulage, so dass eine Verwechslung von Anschlüssen beim Einbau zumindest stark eingeschränkt ist. Zeitersparnis und das Arbeiten an optimalen Arbeitsplätzen, geringere körperliche Belastung der Arbeitskräfte sprechen für die Vorfertigung von Kabelbäumen. Allerdings entsteht ein guter Kabelbaum nicht einfach durch das Bündeln einige Adern, sondern will geplant sein. Mechanische Beanspruchung muss minimiert werden und durch sinnvolle räumliche Anordnung der Abgänge können Fehlbelegungen bei der Montage sogar unmöglich gemacht werden. In der Großserie z.B. für Kfz-Kabelbäume gibt es Standards, entsprechende Software und eine Vielzahl von Hilfsmitteln. Bei Kleinserien sind Planung, Sorgfalt und Erfahrung gefordert, damit statt einigen gebündelten Kabeln ein guter Kabelbaum entsteht. Wir von M. Richter haben uns seit Jahrzehnten den Kleinserien verschrieben und können Sie mit Rat und Tat auch in der Planungsphase unterstützen.