Finden Sie schnell kabel vorkonfektioniert für Ihr Unternehmen: 985 Ergebnisse

RE-2Y(St)HSWAH&RE-2X(St)HSWAH

RE-2Y(St)HSWAH&RE-2X(St)HSWAH

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-TRIPLE, XLPE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Note: Other core configurations manufactured upon request Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2Y(St)HSWAH & RE-2X(St)HSWAH

RE-2Y(St)HSWAH & RE-2X(St)HSWAH

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-TRIPLE, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
Energieleitung

Energieleitung

Die halogenfreie, flexible Energieleitung 0,6/1 kV ist speziell für den Einsatz in der Schiffbauindustrie geeignet. Anwendungsbereich : Die halogenfreie, flexible Energieleitung 0,6/1 kV ist speziell für den Einsatz in der Schiffbauindustrie geeignet. Produktvorteile : - halogenfrei - asbestfrei - keine Brandweiterleitung - flammhemmend und selbstverlöschend - flexibel - für Anwendungen nach Hongkong Convention - Inhaltsstoffe geprüft nach den Vorgaben der Hong Kong Convention (2009) der IMO - Approbationen: Germanischer Lloyd, Lloyd’s Register, American Bureau of Shipping, Registro Italiano Navale
Vierdornzange DigiCrimp® für Luftfahrt-Kontakte 8756 0000 61

Vierdornzange DigiCrimp® für Luftfahrt-Kontakte 8756 0000 61

geeignet zum Vercrimpen von gedrehten Stift- und Buchsenkontakten hauptsächlich nach AS39029 und EN3155 Vierdornzange DigiCrimp® für Luftfahrt-Kontakte 8756 0000 61 geeignet zum Vercrimpen von gedrehten Stift- und Buchsenkontakten hauptsächlich nach AS39029 und EN3155 Crimpdorngeometrie und Adapterring erfüllen die Anforderungen gemäß Luftfahrtnorm AS22520 Multifunktionelle Digitalanzeige, Einstellung in mm, inch oder vergleichbare Selector-Positionen gemäß Luftfahrtnorm AS22520 Crimpdornzustellung in Schritten von 0,01 mm einstellbar und digital ablesbar Überprüfung der Grundeinstellung mittels beiliegendem Prüfstift Rekalibrierungsfunktion elektronische Verschleißüberwachung (patentiert) mit Warnfunktion zuverlässige Vercrimpung durch Zwangsvollendung des Crimpvorganges und synchrone Zustellung der Crimpdorne unterschiedliche Einstellfunktionen abrufbar
AV-SVOAUT-500-80 AUTOMATISCHER RINGAUFWICKLER

AV-SVOAUT-500-80 AUTOMATISCHER RINGAUFWICKLER

Automatischer Auf- und Abwickler für Rund- und Flachkabel Art. AV-SVOAUT-500-80 AUTOMATISCHER RINGAUFWICKLER FÜR KABEL BIS MAX. Ø100 Merkmale Automatischer Auf- und Abwickler für Rund- und Flachkabel. Gefertigt aus lackiertem Stahlblech Abwickelteller mit verstellbarem Kern Zentraler Stift mit Kegel zum Trommelabwickeln Elektrobremse zum Anhalten bei Erreichen der gewünschten Länge AUFWICKLER: variable Geschwindigkeit; mit Zwischenstück zum Abladen mit Gabelstapler. ABWICKLER: Zwischenstück zum Abladen mit Gabelstapler und Kabelspannbremse. MESSGERÄT: mit Längenprogrammierer, Kabeldurchmesser MAX. 100mm Serienmäßige Spannung 220V Verfügbar mit Kabellängenmessgeräten für Kabel MAX. Ø60 und MAX. Ø30
Vierdornzange SelectorCrimp für Luftfahrt-Kontakte

Vierdornzange SelectorCrimp für Luftfahrt-Kontakte

Spezialcrimpzange zum Vercrimpen von gedrehten Stift- und Buchsenkontakten hauptsächlich nach AS39029 und EN3155 Vierdornzange SelectorCrimp für Luftfahrt-Kontakte 8758 0000 6 Spezialcrimpzange zum Vercrimpen von gedrehten Stift- und Buchsenkontakten hauptsächlich nach AS39029 und EN3155 Einsatz von Kontaktaufnahmen nach Luftfahrtnorm AS22520 sowie baugleichen Modellen problemlos möglich Crimpdorne, Adapterring und Selectorstufen erfüllen die Anforderungen gemäß Luftfahrtnorm AS22520 Überprüfung der Grundeinstellung mittels Go-Nogo-Lehren zuverlässige Vercrimpung durch Zwangsvollendung des Crimpvorganges und synchrone Zustellung der Crimpdorne
Vierdornzange SelectorCrimp für Luftfahrt-Kontakte

Vierdornzange SelectorCrimp für Luftfahrt-Kontakte

Spezialcrimpzange zum Vercrimpen von gedrehten Stift- und Buchsenkontakten hauptsächlich nach AS39029 und EN3155 Vierdornzange SelectorCrimp für Luftfahrt-Kontakte 8728 0000 6 Spezialcrimpzange zum Vercrimpen von gedrehten Stift- und Buchsenkontakten hauptsächlich nach AS39029 und EN3155 Einsatz von Kontaktaufnahmen nach Luftfahrtnorm AS22520 sowie baugleichen Modellen problemlos möglich Crimpdorne, Adapterring und Selectorstufen erfüllen die Anforderungen gemäß Luftfahrtnorm AS22520 Überprüfung der Grundeinstellung mittels Go-Nogo-Lehren zuverlässige Vercrimpung durch Zwangsvollendung des Crimpvorganges und synchrone Zustellung der Crimpdorne
Vierdornzange SelectorCrimp für Luftfahrt-Kontakte

Vierdornzange SelectorCrimp für Luftfahrt-Kontakte

Spezialcrimpzange zum Vercrimpen von gedrehten Stift- und Buchsenkontakten hauptsächlich nach AS39029 und EN3155 Einsatz von Kontaktaufnahmen nach Luftfahrtnorm AS22520 sowie baugleichen Modellen problemlos möglich Crimpdorne, Adapterring und Selectorstufen erfüllen die Anforderungen gemäß Luftfahrtnorm AS22520 Überprüfung der Grundeinstellung mittels Go-Nogo-Lehren zuverlässige Vercrimpung durch Zwangsvollendung des Crimpvorganges und synchrone Zustellung der Crimpdorne
Ringwickler AMW1-S4P65

Ringwickler AMW1-S4P65

Die rationelle Art bereits abgelängte Leitungen schnell und problemlos an jedem Ort aufzuwickeln AMW1-S4P65 Ringwickler Die rationelle Art bereits abgelängte Leitungen schnell und problemlos an jedem Ort aufzuwickeln Die Funktion des AMW1-S4P65 Betriebsarten: Manuell und Automatik Im Automatikbetrieb sind über einen Stufenschalter 12 Kabellängen von 2 – 13m vorwählbar. Nach dem Startvorgang über einen Fußschalter stoppt das Gerät automatisch. Im Automatikbetrieb arbeitet das Gerät mit der Maximaldrehzahl von 65 U/min. In der Betriebsart ‚manuell‘ wird die Max. Wickeldauer nur durch den Einsatz des Fußschalters bestimmt. Es kann zwischen vier Drehzahlstufen ausgewählt werden.
Ringwickler AMW1-S4P

Ringwickler AMW1-S4P

Die rationelle Art bereits abgelängte Leitungen schnell und problemlos an jedem Ort aufzuwickeln AMW1-S4P Ringwickler Die rationelle Art bereits abgelängte Leitungen schnell und problemlos an jedem Ort aufzuwickeln Die Funktion des AMW1-S4P Betriebsarten: Manuell und Automatik Im Automatikbetrieb sind über einen Stufenschalter 12 Kabellängen von 2 – 13m vorwählbar. Nach dem Startvorgang über einen Fußschalter stoppt das Gerät automatisch. Im Automatikbetrieb arbeitet das Gerät mit der Maximaldrehzahl von 180 U/min. In der Betriebsart ‚manuell‘ wird die Max. Wickeldauer nur durch den Einsatz des Fußschalters bestimmt. Es kann zwischen vier Drehzahlstufen ausgewählt werden.
Ringwickler AMW1-S4

Ringwickler AMW1-S4

Die rationelle Art bereits abgelängte Leitungen schnell und problemlos an jedem Ort aufzuwickeln AMW1-S4 Ringwickler Die rationelle Art bereits abgelängte Leitungen schnell und problemlos an jedem Ort aufzuwickeln Die Funktion des AMW1-S4 Betriebsarten: Manuell und Automatik Im Automatikbetrieb sind über einen Stufenschalter 12 Kabellängen von 2 – 13m vorwählbar. Nach dem Startvorgang über einen Fußschalter stoppt das Gerät automatisch. Im Automatikbetrieb arbeitet das Gerät mit der Maximaldrehzahl von 240 U/min. In der Betriebsart ‚manuell‘ wird die Max. Wickeldauer nur durch den Einsatz des Fußschalters bestimmt. Es kann zwischen vier Drehzahlstufen ausgewählt werden.
Ringwickler AMW1-P

Ringwickler AMW1-P

Die rationelle Art bereits abgelängte Leitungen schnell und problemlos an jedem Ort aufzuwickeln AMW1-P Ringwickler Die rationelle Art bereits abgelängte Leitungen schnell und problemlos an jedem Ort aufzuwickeln Die Funktion des AMW1-P Im Automatikbetrieb sind über einen Stufenschalter 12 Kabellängen von 2 – 13m vorwählbar. Nach dem Startvorgang über einen Fußschalter stoppt das Gerät automatisch. Im Automatikbetrieb arbeitet das Gerät mit der Maximaldrehzahl von 180 U/min. In der Betriebsart ‚manuell‘ wird die Max. Wickeldauer nur durch den Einsatz des Fußschalters bestimmt.
Ringwickler AMW2-S4

Ringwickler AMW2-S4

Die rationelle Art bereits abgelängte Leitungen schnell und problemlos an jedem Ort aufzuwickeln AMW2-S4 Ringwickler Die rationelle Art bereits abgelängte Leitungen schnell und problemlos an jedem Ort aufzuwickeln Die Funktion des AMW2-S4 Betriebsarten: Manuell und Automatik Im Automatikbetrieb sind über einen Stufenschalter 12 Kabellängen von 2 - 13m vorwählbar. Nach dem Startvorgang über einen Fußschalter stoppt das Gerät automatisch. Im Automatikbetrieb arbeitet das Gerät mit der Maximaldrehzahl von 180 U/min. In der Betriebsart 'manuell' wird die Max.  Wickeldauer nur durch den Einsatz des Fußschalters bestimmt. Es kann zwischen vier Drehzahlstufen ausgewählt werden.
Vollatuomatische Anlage zum Schneiden von Hochfrequenz-Koaxialkabeln

Vollatuomatische Anlage zum Schneiden von Hochfrequenz-Koaxialkabeln

Einwandfreie Bearbeitung steifer Kabel ohne Kratz-, Druck- oder Scheuerspuren, durch den Einsatz eines Rotativschnitts durch mehrere Materialschichten. Die einwandfreie Bearbeitung von Hochfrequenz-Wellmantel-Koaxialkabel ist mit einer handelsüblichen Serienmaschine nicht möglich. Deswegen entwickelte Metzner für einen führenden Anbieter auf dem Gebiet der Hochfrequenz-Koaxial-Steckverbindungen, ein wegweisendes Verfahren für die vollautomatische Bearbeitung dieser Kabel. Ausgangspunkt des vollautomatischen Bearbeitungsprozesses ist eine materialspezifische Richtstation zur Ausrichtung der ungewöhnlich steifen Kabel. Diese Ausrichtung ist sowohl für die nachfolgenden Bearbeitungsschritte als auch für die spätere Weiterverarbeitung eine wichtige Voraussetzung. Als Herzstück für das Bearbeitungsverfahren verwendet Metzner einen neuentwickelten Abisolierkopf, der einen Rotativschnitt mit einer kraftvollen Klemmung und einer gleichzeitigen Drehung des Materials kombiniert. Auf diese Weise gelingt der hochpräzise und mehrstufige Radialschnitt durch die verschiedenen Materialschichten. Die Qualitätsprüfung unter dem Mikroskop bestätigt die einwandfreie Bearbeitung ohne jegliche Kratz-, Druck oder Scheuerspuren. Neben der hohen Bearbeitungsqualität bietet die Anlage auch eine besondere Präzision: Sowohl die Gesamtlänge als auch die Bearbeitungsposition werden mit einer Genauigkeit von 0,2 mm eingehalten. Die Maschine kann Kabel mit einem Durchmesser von bis zu 28 mm zu verarbeiten. Die Verarbeitungsschritte sind Langschlitzen, Absägen, umlaufenden Schnitt einschneiden, Abmanteln, Bürsten und Ablegen. Ein integrierter Tintenstrahl-Drucker beschriftet die Kabel mit Informationen bzw. Markierungen, die für die Weiterverarbeitung nötig sind. HOHE BEARBEITUNGSQUALITÄT UND BESONDERE PRÄZISION Die Metzner-Spezialentwicklung ist in der Lage, Kabel mit einem Durchmesser von bis zu 28 mm zu verarbeiten. Die Taktzeit dafür liegt bei 2000 mm / 35 Sekunden.
Metzner EM 100 - Einzelstation zum Kabelschirm entflechten und Kabelfolie entfernen

Metzner EM 100 - Einzelstation zum Kabelschirm entflechten und Kabelfolie entfernen

Die Metzner EM100 bietet eine Lösung zum automatischen Kabelschirm Entflechten & Schneiden sowie Entfernen der Kabelfolie ohne Verletzung des Schirmgeflechts. Patentiertes Verfahren zur automatischen Bearbeitung von Kabelschirmen! Für den Einstieg in die Hochspannungskabelverarbeitung bietet Metzner im Bereich E‑Mobility preiswerte Einzelstationen an. Das EM 101 Modul bietet erstmals eine Lösung zum Entfernen der Kabelfolie ohne den Kabelschirm zu beeinträchtigen. Die automatische Hochvolt Kabelverarbeitung erfordert auch den Anschluss verschiedener Komponenten des Stecksystems. Dafür ist die Metzner EM 102 zuständig. Die EM 103 ermöglicht das Öffnen und Schneiden des Kabelschirms mit einem patentierten Verfahren, das sicherstellt, dass absolut kein Kontakt mit der Innenisolierung besteht. Die EM 103S bietet die Funktionalität der bewährten EM 103 für die Anforderungen kleinerer Kabel bis 8 mm Durchmesser. Diese kostengünstigen Modelle zur Kabelkonfektionierung können nicht in eine Automatisierungslinie eingebunden werden und sind nur mit eingeschränkten Rückverfolgbarkeitsfunktionen ausgestattet.
BayMotion®  Flex Power+  0,6/1 kV  3-5-adrig

BayMotion® Flex Power+ 0,6/1 kV 3-5-adrig

Hochflexible, halogenfreie, flammwidrige, UV- und witterungsbeständige, erdverlegbare Anschlussleitung mit einer sehr temperaturbeständigen Leiterisolierung aus einer speziellen HP Elastomermischung. BayMotion® CPR Eca Flex Power + ist eine hochflexible, halogenfreie, flammwidrige, UV- und witterungsbeständige, erdverlegbare Anschlussleitung mit einer sehr temperaturbeständigen Leiterisolierung aus einer speziellen HP Elastomermischung für den Einsatz im Anlagen- und Maschinenbau. Die Leitung ist ölbeständig und garantiert eine lange Lebensdauer in belasteter Umgebung, z. B. bei Anschlüssen von Transformatoren. universell einsetzbar, zur festen Verlegung in trockenen und feuchten Räumen, im Freien und direkt in Erde Einfache Montage durch hochflexible Ader Temperaturbeständige Leiterisolierung für erhöhte Strombelastbarkeit Optional auch für 1,8/3 kV erhältlich *) im Dreieck mit Berührung angeordnet. Die Anforderungen der Strombelastbarkeit nach VDE 0276-603 Teil 5G beachten.
BayMotion®  Flex Power+  0,6/1 kV  1-adrig

BayMotion® Flex Power+ 0,6/1 kV 1-adrig

Hochflexible, halogenfreie, flammwidrige, UV- und witterungsbeständige, erdverlegbare Anschlussleitung mit einer sehr temperaturbeständigen Leiterisolierung aus einer speziellen HP Elastomermischung. BayMotion® CPR Eca Flex Power + ist eine hochflexible, halogenfreie, flammwidrige, UV- und witterungsbeständige, erdverlegbare Anschlussleitung mit einer sehr temperaturbeständigen Leiterisolierung aus einer speziellen HP Elastomermischung für den Einsatz im Anlagen- und Maschinenbau. Die Leitung ist ölbeständig und garantiert eine lange Lebensdauer in belasteter Umgebung, z. B. bei Anschlüssen von Transformatoren." Universell einsetzbar, zur festen Verlegung in trockenen und feuchten Räumen, im Freien und direkt in Erde Einfache Montage durch hochflexible Ader Temperaturbeständige Leiterisolierung für erhöhte Strombelastbarkeit Optional auch für 1,8/3 kV erhältlich *) im Dreieck mit Berührung angeordnet. Die Anforderungen der Strombelastbarkeit nach VDE 0276-603 Teil 5G beachten.
BayMotion®  Flex Power+  1,8/3 kV 1-adrig

BayMotion® Flex Power+ 1,8/3 kV 1-adrig

Hochflexible, halogenfreie, flammwidrige, UV- und witterungsbeständige, erdverlegbare Anschlussleitung mit einer sehr temperaturbeständigen Leiterisolierung aus einer speziellen HP Elastomermischung. BayMotion® CPR Eca Flex Power + ist eine hochflexible, halogenfreie, flammwidrige, UV- und witterungsbeständige, erdverlegbare Anschlussleitung mit einer sehr temperaturbeständigen Leiterisolierung aus einer speziellen HP Elastomermischung für den Einsatz im Anlagen- und Maschinenbau. Die Leitung ist ölbeständig und garantiert eine lange Lebensdauer in belasteter Umgebung, z. B. bei Anschlüssen von Transformatoren. Universell einsetzbar, zur festen Verlegung in trockenen und feuchten Räumen, im Freien und direkt in Erde Einfache Montage durch hochflexible Ader Temperaturbeständige Leiterisolierung für erhöhte Strombelastbarkeit Optional auch für 0,6/1 kV erhältlich *) im Dreieck mit Berührung angeordnet. Die Anforderungen der Strombelastbarkeit nach VDE 0276-603 Teil 5G beachten.
RE-2Y(St)H & RE-2X(St)H MP

RE-2Y(St)H & RE-2X(St)H MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black cores numbered 1-2-3…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Standard: TS/DIN EN 50288-7 Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2
RE-2G(St)HSWAH-CI  FE180 MP

RE-2G(St)HSWAH-CI FE180 MP

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, SILICONE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ
RE-2G(St)H-CI-PIMF  FE180

RE-2G(St)H-CI-PIMF FE180

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Core identification: Black / Blue ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / Blue cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, pon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 300 MΩ.km Mutual Capacitance: max. 150 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ
BayEnergy®  N2XCWH  0,6/1 kV  4 +1-adrig

BayEnergy® N2XCWH 0,6/1 kV 4 +1-adrig

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die EMV+ Konstruktion wird speziell im 4+1 Leitersystem TN-S mit einem getrennten Neutralleiter (N) und querschnittsgleichem Schutzleiter (PE) eingesetzt. Durch den besseren Leitwert im PE-Leiter werden EMV-Störungen optimal reduziert und bieten einen höheren Schutz als bei Kabeln mit reduziertem Außenleiter (4½-Leiter). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung.
BayEnergy® N2XC2Y  0,6/1 kV  1-3-adrig

BayEnergy® N2XC2Y 0,6/1 kV 1-3-adrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
RE-2Y(St)H&RE-2X(St)H-MP

RE-2Y(St)H&RE-2X(St)H-MP

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)H,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: According to BS 5308 Part 1 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Pairs laid up in layers of optimum pitch Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2G(St)HSWAH-CI  FE180

RE-2G(St)HSWAH-CI FE180

HALOGEN-FREE FIRE RESISTANT (Cl) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, SILICONE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ
RE-2Y(St)H & RE-2X(St)H-MP

RE-2Y(St)H & RE-2X(St)H-MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Min. bending radius: 7,5 x D Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4
RE-2G(St)HSWAH-CI-PIMF  FE180

RE-2G(St)HSWAH-CI-PIMF FE180

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / Blue cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 300 MΩ.km Mutual Capacitance: max. 150 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC
BayEnergy® N2XY-O  0,6/1 kV  4-5-adrig

BayEnergy® N2XY-O 0,6/1 kV 4-5-adrig

Starkstromkabel für höhere Leitertemperaturen, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist. Im Innen- und Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
RE-2G(St)H-CI  FE180 MP

RE-2G(St)H-CI FE180 MP

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, SILICONE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2
BayEnergy® N2XY-J  0,6/1 kV  4-5-adrig

BayEnergy® N2XY-J 0,6/1 kV 4-5-adrig

Starkstromkabel für höhere Leitertemperaturen, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist. Im Innen- und Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.