Finden Sie schnell der kabel das kabel für Ihr Unternehmen: 1550 Ergebnisse

RE-2Y(St)YSWAY-fl-PIMF & RE-2X(St)YSWAY-fl-PIMF

RE-2Y(St)YSWAY-fl-PIMF & RE-2X(St)YSWAY-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)YSWAY-fl-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (2Y): PVC compound, EN 50290-2-22 Inner sheath (2X): PVC compound, 90OC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
Heyco Kabelzugentlastungen für Flachkabel

Heyco Kabelzugentlastungen für Flachkabel

Als offizieller Heyco Vertriebspartner haben wir Zugang zu allen Heyco Produkten - 3D Dateien ✓ Kostenlose Muster ✓ Technische Beratung ✓ Heyco Kabelzugentlastungen mit geradem Durchgang für Flachkabel. Montagelochdurchmesser von 11.1 mm bis 22.2 mm. • Geeignet für Langlöcher • Verhindert Zugbelastung und Verschleiß an Kabeln • Verankert, isoliert und schützt das Kabel sicher an den Eingangspunkten Hinweise: P = Maximale Plattenstärke. Artikel hat zusätzlichen Freiraum Type UL: UL Industriestandard SRB030 - Längliches Montageloch SRB031 - Vorgestanzte Ausbrechlöcher mit 12,7 mm Werkstoff - Nylon 6/6 Brandklasse: 94V-2 Temperaturbereich: -18°C bis 105 °C Zertifizierungen: • Anerkannt unter dem Komponentenprogramm „Component Program of Underwriters’ Laboratories“, Datei E15331 • & „Canadian Standards Association“, Datei 8919 Wünschen Sie weitere Informationen oder ein unverbindliches Angebot?
Kabeldurchlass

Kabeldurchlass

Kabeldurchlass mit Klappe und Bürstendichtung Aluminium eloxiert 9133406 Kabeldurchlass Aluminium 70 mm x 200 mm• Mit Klappe und Bürstendichtung• Aluminium eloxiert Artikelnummer: E9133406 Gewicht: 0.231 kg
PERFECT Pg Kabelverschraubung Messing

PERFECT Pg Kabelverschraubung Messing

Die PERFECT Kabelverschraubung aus vernickeltem Messing ist die passende Lösung zur Kabeldurchführung in verschiedensten industriellen Anwendungen. Eigenschaften: - integrierte Zugentlastung für Kabel und Leitungen - Verdrehschutz - großer Dicht- und Klemmbereich - für Leitungen von 3 bis 44 mm - montagefreundlich - Temperaturbereich-20 °C / +100 °C (dynamisch) -40 °C (statisch, kurzzeitig) - Schutzart IP68 - 5 bar - viele Varianten und Zubehörteile verfügbar PERFECT PERFECT Pg 50.0xx 50.0xx Material: Messing vernickelt Schutzart: IP68 - 5 bar, IP69K Für Kabeldurchmesser: 3-48 mm
Edelstahl Kabelbinder

Edelstahl Kabelbinder

Kabelbinder aus Edelstahlband AISI 316 mit zusätzlicher Kugelsperre für Anwendungen mit hohen Belastungen - Kostenlose Muster ✓ Schnelle Lieferung ✓ Persönliche Beratung ✓ Diese Kabelbinder sind aus Edelstahlband AISI 316 hergestellt und haben zusätzlich eine Kugelsperre, wodurch sie sich besonders für Anwendungen mit hohen Belastungen eignen. Sie zeichnen sich durch eine hohe Korrosionsbeständigkeit und Resistenz gegenüber Chemikalien aus, zudem sind sie wetterbeständig. Typische Anwendungen: Flugzeuge, Kraftwerke, Gruben, Tunnel, Öl- und Gasbohrinsel Werkstoff - Edelstahl AISI 316 B = Maximaler Bündeldurchmesser S = Mindeststärke in kg Wünschen Sie weitere Informationen, kostenlose Muster oder ein unverbindliches Angebot?
Hettlock RFID Verbindungskabel Master / Slave

Hettlock RFID Verbindungskabel Master / Slave

Hettlock RFID Verbindungskabel Master / Slave 1 Kabel zum Verbinden der Master / Slave-Schlösser Länge 5000 mm 9206930 Verbindungskabel Master / Slave• 1 Kabel zum Verbinden der Master / Slave-Schlösser Artikelnummer: E9206930 Gewicht: 0.0052 kg
Messing Kabelverschraubungen

Messing Kabelverschraubungen

Kabelverschraubungen aus Messing sichern und schützen Kabel beim führen durch Metalplatten - Lagerbestand ✓ Schnelle Lieferung ✓ Persönliche Beratung ✓ Diese Kabelverschraubungen aus Messing sichern und schützen Kabel die durch Metalplatten geführt werden. Zusammen mit unserem O-Ring entsprechen sie den IP68 Anforderungen. Kabelverschraubungen aus Messing werden komplett mit O-Ring geliefert. Werkstoff - Messing (Vernickelt) Durchmesser = Kabeldicke Wünschen Sie weitere Informationen oder ein kostenloses Angebot?
NHLSH -OZ

NHLSH -OZ

HALOGEN-FREE, CONTROL CABLES These halogen-free cables are used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines. These cables are used at covered areas, plants and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. These cables are not used for outdoor or underground installation. Conductor: Flexible copper wires, plain;, IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: HFFR compound, HI2 , VDE 0207-23 Core identification: According to TS/DIN EN 50334 black cores, with white numerals Lay-up: Cores laid up in layers of optimum pitch Separator: Polyester tape Outer sheath: HFFR compound, HM2, VDE 0207-24 Sheath colour: RAL 7001,Grey Standard: VDE 0245-201, (Designed according to) Insulation resistance: Min. 20 MΩ.km Rated voltage: 300 / 500V Test voltage: 2000 V Temperature range: Fixed: - 30 oC ~ + 70 oC, Mobile: - 5 oC ~ + 50 oC Min. bending radius: Fixed: 8 x D, Mobile: 15 x D Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Flame test: IEC 60332-3 & TS/DIN EN 50266-2-4
RE-2Y(St)YQY-fl MP

RE-2Y(St)YQY-fl MP

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, STEEL WIRE BRAIDED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the sheath, steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation.These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: PVC compound, EN 50290-2-22 Armour: Braid of galvanized steel wires, aprx. %85 cov. Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm
RE-2Y(St)HSWAH&RE-2X(St)HSWAH

RE-2Y(St)HSWAH&RE-2X(St)HSWAH

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-TRIPLE, XLPE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Note: Other core configurations manufactured upon request Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP

RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)H-PIMF&RE-2X(St)H-PIMF

RE-2Y(St)H-PIMF&RE-2X(St)H-PIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)H-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)H-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / blue ; with numbered tape under, separator tape of the pair screen, Note: Other core configurations manufactured upon request Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2G(St)H-CI  FE180

RE-2G(St)H-CI FE180

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, SILICONE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ
PERFECT Fix Kabelverschraubung Kunststoff

PERFECT Fix Kabelverschraubung Kunststoff

Die PERFECT Fix Kabelverschraubung ist die passende Lösung zur Kabeldurchführung an schwer zugänglichen Stellen. Eigenschaften: - problemloser Ein- und Ausbau von einer Seite - kein Innengewinde erforderlich - kontern an der Gehäuseinnenseite entfällt - schnelle und einfache Montage ohne Spezialwerkzeug - vorteilhaft für den Einsatz an schwer zugänglichen Stellen - integrierte Zugentlastung für Kabel und Leitungen - großer Dicht- und Klemmbereich - für Leitungen von 3 bis 21 mm - für Wandstärken von 1-4 mm stufenlose einstellbar - Temperaturbereich -20 °C / +100 °C - Schutzart IP68 Jacob PERFECT Fix PERFECT Fix K341-1xxx-zz / K344-1xxx-zz K341-1xxx-zz / K344-1xxx-zz Material: Polyamid PA6 Schutzart: IP68 Für Kabeldurchmesser: 3 - 21 mm
HF-Kabel Bipolar (Euro-Flachstecker geschützt / Martin-Berchtold-Stecker)

HF-Kabel Bipolar (Euro-Flachstecker geschützt / Martin-Berchtold-Stecker)

Unsere HF-Kabel stellen eine zuverlässige und sichere Verbindung, zu allen gängigen Generatoren her. Das umfangreiche Sortiment umfasst, sowohl Standardanschlüsse als auch zahlreiche Stecker- Varianten für Sonderinstrumente. • Flexibel und ohne Memory Effekt durch feine verseilte Einzellitzen • Lange Lebensdauer und hohe Korrosionsbeständigkeit durch einzeln versilberte Litzen • Maximale elektrische Sicherheit durch hochwertige Isolationswerkstoffe • Hypoallergen durch hochwertigen Silikonmantel • Standardlänge 3 und 5m (Sonderlängen auf Wunsch) • Sterilisierbar im Autoklav-Verfahren • Getestet nach den einschlägigen Normen 3 Meter:: MC91018 5 Meter:: MC91019
Vibrationsfeste Kabelbinder mit Zwei Edelstahlzungen

Vibrationsfeste Kabelbinder mit Zwei Edelstahlzungen

Innovative Kabelbinder mit hervorragende Vibrationsbeständigkeit und Sicherheit bei dynamischen Belastungen durch zwei Edelstahlzungen - 3D Dateien ✓ Kostenlose Muster ✓ Technische Beratung ✓ Diese leistungsstarken 2-Lock-Kabelbinder bieten mit Ihrem innovativen Verriegelungssystems auf der Basis eines übergeformten Edelstahlkäfig mit Doppelzahn hervorragende Vibrationsbeständigkeit und Sicherheit bei dynamischen Belastungen. Der Kabelbinder ist auf beiden Seiten vollkommen glatt, daher entfällt das Abriebrisiko, da es keine Ratschen Punkte gibt an denen der Binder einrastet. Die schwarzen 2-Lock Kabelbinder sind durch die Verwendung von Industrieruß ebenfalls UV resistent. Extrem widerstandsfähig Glatte Oberfläche - Vibrationsfest Frei arretierbar Temperaturen von -40 bis +85 °C (Montagetemperatur bis +60 °C) Kennzeichnung UL94 V2 (Test zur Brennbarkeit von Kunststoffen) Halogenfrei Wiederverschließbare und recycelbare Verpackungen Zertifikate: DNV GL (Det Norske Veritas & Germanischer Lloyd) - Schifffahrts-, Gas & Öl-, Stromindustrie UL (Underwriters Lab) - US Standards PPAP - Automobilindustrie Typische Anwendungen: Automobilindustrie, Schaltanlagen, Elektroinstallationen, Industrielle Verkabelungen, Anwendungen mit schwierigen Bedingungen Material - PA6.6 (Kabelbinder), Edelstahl 316 (Zungen), (+1% Industrieruß bei der schwarzen Version) Standardfarben - Natur, Schwarz 2-Lock ist eine eingetragene Handelsmarke von Elematic (ITW Construction Products) B = Minimum bis Maximum Bündelung S = Zugkraft Wünschen Sie weitere Informationen, kostenlose Muster oder ein unverbindliches Angebot?
HF-Kabel Bipolar (US-Rundpin-Pinzettenstecker / Erbe-Storz-Stecker)

HF-Kabel Bipolar (US-Rundpin-Pinzettenstecker / Erbe-Storz-Stecker)

Unsere HF-Kabel stellen eine zuverlässige und sichere Verbindung, zu allen gängigen Generatoren her. Das umfangreiche Sortiment umfasst, sowohl Standardanschlüsse als auch zahlreiche Stecker- Varianten für Sonderinstrumente. • Flexibel und ohne Memory Effekt durch feine verseilte Einzellitzen • Lange Lebensdauer und hohe Korrosionsbeständigkeit durch einzeln versilberte Litzen • Maximale elektrische Sicherheit durch hochwertige Isolationswerkstoffe • Hypoallergen durch hochwertigen Silikonmantel • Standardlänge 3 und 5m (Sonderlängen auf Wunsch) • Sterilisierbar im Autoklav-Verfahren • Getestet nach den einschlägigen Normen 3 Meter:: MC91012 5 Meter:: MC91016
Kabeldurchlass Ø=80 mm

Kabeldurchlass Ø=80 mm

Kabeldurchlass Ø=80 mm Kunststoff grau, mit flexibler Bürstendichtung, zum Eindrücken 9081329 Kabeldurchlass Kunststoff / Bürste rund, 80 mm, grau• Kunststoff Artikelnummer: E9081329 Gewicht: 0.02 kg
Klappenhalter mit Seilzug LiftMini

Klappenhalter mit Seilzug LiftMini

Klappenhalter mit Seilzug LiftMini Horizontal-Vertikal einsetzbar Kunststoff grau 9206689 Klappenhalter mit Seilzug, 140N• Für Holzfronten oder Rahmenfronten aus Holz • Öffnungs- und Schließdämpfung• Klappengewicht inkl. Griff max. 1,4 - 14,5 kg• Klappenmaße: Höhe 200 - 480 mm• Zum Aufschrauben auf die Korpusseite, rechts / links verwendbar• horizontal und vertikal einsetzbar für besonders geringen Platzbedarf• Klappenbeschlag Kunststoff grau• Frontbefestigung Zinkdruckguss vernickelt• Abdeckkappe, bitte separat bestellen• Klappe muss unten mit Topfscharnieren oder Klappenscharnieren angeschlagen werden, bitte separat bestellen Set besteht aus:• 1 Stück Klappenbeschlag• 1 Stück Frontbefestigung für Holzfronten• Befestigungsmaterial (Euroschrauben für Klappenbeschlag und Frontbefestigung) Artikelnummer: E9206689 Gewicht: 0.331 kg
RCG Rapid Connection Kabelverschraubung

RCG Rapid Connection Kabelverschraubung

Die 501/RCG ist eine Schnellanschlussverschraubung und kann für den schnellen Feldanschluss von Kabeln an Geräten verwendet werden, bei denen traditionell feste Verdrahtungsmethoden zum Einsatz kommen. Diese Lösung erzielt Kosteneinsparungen bei der Durchführung von wichtigen Inspektions- und Wartungsarbeiten, einschließlich der Möglichkeit, Geräte vor Ort schnell auszutauschen. Werkstoff: Messing, galvanisch vernickelt Zündschutzarten: Ex II 2 GD, Ex eb IIC T6/T5 Gb, Ex tb IIIC T80°C/95°C Db Einsetzbar in Zone 1, Zone 2, Zone 21, Zone 22 und in den Gasgruppen IIA, IIB und IIC 4 oder 6 Pins Aderquerschnitt von 0,75 bis 6,0 mm² Maximale Spannung 300VAC/212 VDC Maximale Stromstärke abhängig vom Aderquerschnitt, max. 30 Ampère Temperaturbereich: -60 °C / +60 °C Schutzarten: IP66, IP67, Deluge Protected DTS01 HAWKE HAWKE 501/RCG 501/RCG
Klappenhalter mit Seilzug LiftMini

Klappenhalter mit Seilzug LiftMini

Klappenhalter mit Seilzug LiftMini Horizontal-Vertikal einsetzbar Kunststoff grau 9206675 Klappenhalter mit Seilzug, 40N• Für Holzfronten oder Rahmenfronten aus Holz • Öffnungs- und Schließdämpfung• Klappengewicht inkl. Griff max. 1,4 - 14,5 kg• Klappenmaße: Höhe 200 - 480 mm• Zum Aufschrauben auf die Korpusseite, rechts / links verwendbar• horizontal und vertikal einsetzbar für besonders geringen Platzbedarf• Klappenbeschlag Kunststoff grau• Frontbefestigung Zinkdruckguss vernickelt• Abdeckkappe, bitte separat bestellen• Klappe muss unten mit Topfscharnieren oder Klappenscharnieren angeschlagen werden, bitte separat bestellen Set besteht aus:• 1 Stück Klappenbeschlag• 1 Stück Frontbefestigung für Holzfronten• Befestigungsmaterial (Euroschrauben für Klappenbeschlag und Frontbefestigung) Artikelnummer: E9206675 Gewicht: 0.33 kg
Abdeckkappen für Klappenhalter mit Seilzug

Abdeckkappen für Klappenhalter mit Seilzug

Abdeckkappen für Klappenhalter mit Seilzug LiftMini, schwarz 9206695 Abdeckkappen, schwarz Artikelnummer: E9206695 Gewicht: 0.43 kg
RE-Y(St)YSWAY-fl-MP

RE-Y(St)YSWAY-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED,ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: According to BS 5308 Part 2 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PVC compund, TM1, BS 7655, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 2 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
Kabeldurchlass

Kabeldurchlass

Kabeldurchlass mit Bürstendichtung Aluminium eloxiert 9133407 Kabeldurchlass Aluminium 53 mm x 600 mm• Mit Bürstendichtung• Aluminium eloxiert Artikelnummer: E9133407 Gewicht: 0.502 kg
Easys Kabelbinder-Set

Easys Kabelbinder-Set

Easys Kabelbinder-Set bestehend aus je 50 Stück Grundplatten und Kabelbinder 9109834 Set KabelbinderSet besteht aus:• 50 Stück selbstklebende Grundplatten• 50 Stück Kabelbinder Artikelnummer: E9109834 Gewicht: 0.063 kg
Verbindungsleitung LED SuperStripe

Verbindungsleitung LED SuperStripe

Verbindungsleitung LED SuperStripe 3630802 Artikelnummer: E3630802 Gewicht: 0.03 kg
Kabeldurchlass Ø=60 mm

Kabeldurchlass Ø=60 mm

Kabeldurchlass Ø=60 mm Kunststoff Alu-Finish, mit flexibler Bürstendichtung, zum Eindrücken 9081331 Kabeldurchlass Kunststoff / Bürste rund, 60 mm, Aluminium Optik• Kunststoff Artikelnummer: E9081331 Gewicht: 0.02 kg
BIRTFLEX 5511-PUR

BIRTFLEX 5511-PUR

PVC INSULATED, PUR SHEATED CONTROL CABLES These flexible PUR sheathed connecting cables are more used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines and flexible applications for free movement with low tensile load at heavy conditions, dry, ambitient and wet places. These cables can be used at outdoor applications at fixed installations. Conductor: Flexible copper wires, plain; IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: PVC compound , TI2 Core identification: Acc. to TS/DIN EN 50334 black cores with white numerals with green/yellow from 3 cores Lay-up: Cores laid up in layers of optimum pitch Inner Sheath: PVC compound Outer sheath: PUR compound, 11YM1 Sheath colour: RAL 7001,Grey Standard: TS HD 21.13 S1, DIN VDE 0281-13 VDE 0245-102, DIN VDE 0282-10 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: 300 / 500V Test voltage: 4000 V Temperature range: Fixed: - 40 oC ~ + 70 oC; Mobile: - 5 oC ~ + 70 oC Min. bending radius: Fixed: 4 x D; Mobile: 10 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1
RE-2G(St)H-CI-PIMF  FE180

RE-2G(St)H-CI-PIMF FE180

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Core identification: Black / Blue ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / Blue cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, pon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 300 MΩ.km Mutual Capacitance: max. 150 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ
HF-Kabel Monopolar (4mm Federkorb-buchsen-Stecker / Erbe-ACC/ICC-VIO-Stecker)

HF-Kabel Monopolar (4mm Federkorb-buchsen-Stecker / Erbe-ACC/ICC-VIO-Stecker)

Unsere HF-Kabel stellen eine zuverlässige und sichere Verbindung, zu allen gängigen Generatoren her. Das umfangreiche Sortiment umfasst, sowohl Standardanschlüsse als auch zahlreiche Stecker- Varianten für Sonderinstrumente. • Flexibel und ohne Memory Effekt durch feine verseilte Einzellitzen • Lange Lebensdauer und hohe Korrosionsbeständigkeit durch einzeln versilberte Litzen • Maximale elektrische Sicherheit durch hochwertige Isolationswerkstoffe • Hypoallergen durch hochwertigen Silikonmantel • Standardlänge 3 und 5m (Sonderlängen auf Wunsch) • Sterilisierbar im Autoklav-Verfahren • Getestet nach den einschlägigen Normen 3 Meter:: MC92010 5 Meter:: MC92000