Finden Sie schnell cat6 ethernet kabel für Ihr Unternehmen: 55 Ergebnisse

RE-2Y(St)H-PIMF&RE-2X(St)H-PIMF

RE-2Y(St)H-PIMF&RE-2X(St)H-PIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)H-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)H-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / blue ; with numbered tape under, separator tape of the pair screen, Note: Other core configurations manufactured upon request Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
E-DAT modul Cat.6A 8(8) Buchse

E-DAT modul Cat.6A 8(8) Buchse

‧ modulare Anschlusseinheit Cat.6A, RJ45 ‧ Cat.6A Komponentenprüfung nach ISO/IEC 11801, DIN EN 50173-1, ANSI/TIA-568.2-D und IEC 60603-7-51, GHMT zertifiziert ‧ Einhaltung der Klasse EA nach ISO/IEC 11801, DIN EN 50173-1 ‧ getestet: Link bis 500 MHz ‧ montagefreundlicher Anschluss der 2- bis 4-paarigen Datenleitung AWG 26/1 - 22/1 und Litzenleiter mit 7-drähtiger Cu-Litze AWG 26/7 - 22/7 an BTR 8fach IDC-Schneidklemmen ‧ Kennzeichnung der Adernbelegung T568A und T568B ‧ leichtes und schnelles Einlegen der Adernpaare in das E-DAT modul Ladestück ‧ Modulgehäuse aus Zinkdruckguss, veredelt ‧ Montage ohne Spezialwerkzeug ‧ Zugentlastung mit Kabelbinder am Modul ‧ Befestigungsmöglichkeit für Staubschutzklappe ‧ Einbauform: MC Modul ‧ Kabelzuführung 180° ‧ Lieferung in einer 10er Verpackung, einzeln lieferbar
Gigabit-Ethernet-Extender und Serial Extender von PHOENIX CONTACT

Gigabit-Ethernet-Extender und Serial Extender von PHOENIX CONTACT

Ethernet-Extender sind eine kostengünstige Möglichkeit, Ethernet-Netzwerke über große Entfernungen zu verbinden. Gigabit-Anwendungen und Reichweiten bis zu 20 km sind möglich. Minimieren Sie die Investitionskosten, indem Sie die vorhandene Verkabelung für anspruchsvolle Ethernet-Installationen verwenden. Finden Sie den richtigen Extender für Ihre Anwendung.
Elektronische Messgeräte für Präzise Daten in Echtzeit

Elektronische Messgeräte für Präzise Daten in Echtzeit

Herzlich willkommen bei DRUCK & TEMPERATUR Leitenberger GmbH, Ihrem renommierten Anbieter für hochmoderne elektronische Messgeräte. Unsere Produkte verkörpern Spitzenqualität in der Messtechnik und bieten fortschrittliche Lösungen für präzise Datenerfassung in Echtzeit. Innovation und Tradition Hand in Hand Unsere elektronischen Messgeräte profitieren von jahrzehntelanger Erfahrung. Als Teil der LEITENBERGER-Firmengruppe, einer seit 1969 führenden Entwicklungs- und Lieferpartnerin weltweit, repräsentieren unsere Produkte höchste Qualität und technologische Exzellenz. Technologische Präzision Die elektronischen Messgeräte von DRUCK & TEMPERATUR Leitenberger GmbH setzen Maßstäbe durch fortschrittliche Technologien. Mit präzisen Sensoren und elektronischer Raffinesse ermöglichen sie akkurate Messungen, die höchsten Ansprüchen gerecht werden. Vielseitigkeit und Anpassungsfähigkeit Unsere breite Palette von elektronischen Messgeräten bietet Lösungen für eine Vielzahl von Anforderungen. Ob in der Industrie, Forschung oder anderen Anwendungsgebieten – wir haben das passende Gerät für Ihre spezifischen Bedürfnisse. Dank unserer hohen Fertigungstiefe sind wir flexibel und können individuelle Kundenanforderungen erfüllen, während wir gleichzeitig höchste Qualitätsstandards einhalten. Echtzeitdaten für präzise Entscheidungen Unsere elektronischen Messgeräte liefern nicht nur Daten, sondern ermöglichen auch eine schnelle und präzise Analyse in Echtzeit. Damit unterstützen sie effektive Entscheidungsprozesse in Ihrem Unternehmen. Kundenspezifische Komplettlösungen Wir bei DRUCK & TEMPERATUR Leitenberger GmbH verstehen, dass jede Anwendung einzigartig ist. Daher bieten wir nicht nur erstklassige elektronische Messgeräte, sondern auch maßgeschneiderte Komplettlösungen. Unser engagiertes, zuverlässiges und fachkompetentes Team steht Ihnen zur Seite, um Ihre spezifischen Anforderungen zu verstehen und individuelle Lösungen anzubieten. Globale Präsenz und Serviceorientierung Mit einer Exportquote von etwa 40% beliefern wir Kunden weltweit. Unser Motto "Engineered and Made in Germany" steht für höchste Standards, denen wir uns als mittelständisches Entwicklungs-, Fertigungs- und Vertriebsunternehmen verschrieben haben. Vertrauen Sie auf DRUCK & TEMPERATUR Leitenberger GmbH als Ihren globalen Partner für exzellente Messtechnik. Entdecken Sie die Welt der präzisen Datenerfassung in Echtzeit mit DRUCK & TEMPERATUR Leitenberger GmbH – Ihr Wegbereiter für Innovation, Qualität und Zuverlässigkeit in der Messtechnik.
RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF

RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
Offshore-Kabel

Offshore-Kabel

Hradil integriert Lichtwellenleiter in seine konstruktiven Überlegungen für optisch-elektrische Hybridkabel.
Typ TN-S, Installationskabel und Sicherheits-Installationskabel mit Funktionserhalt

Typ TN-S, Installationskabel und Sicherheits-Installationskabel mit Funktionserhalt

CFW PowerCable bis CPS 4×300/PE150 PUR FR Gemäß CPR/BauPVO halogenfrei und flammwidrig oel- UV- und witterungsbeständig Klassifizierung nach EN 13501-6: E
BKDATA Ethernet Cat. 5e 4x2x26/7 AWG

BKDATA Ethernet Cat. 5e 4x2x26/7 AWG

Industrial Ethernet direkt vom Hersteller. Erhältlich als PVC & PUR-Variante Standardaufmachungen ab Lager (ab 2019): 100 m-Ring, 500 m auf Spule und 1.000 m auf Spule. Verkabelung nach EN 50173 Industrial Ethernet Kategorie 5e mit einer Übertragungsrate bis 1.000 MBit/s Erfüllt Echtzeitanforderungen für Industrie 4.0 Für feste Verlegung und flexible Anwendungen geeignet Ermöglicht Patchkabel-Anwendungen bis max. 60 Meter Halogenfrei
Energieübertragungssysteme, kontaktlose

Energieübertragungssysteme, kontaktlose

Kundenspezifische Schalenkerne Blinzinger - Ihr Spezialist für Design und Herstellung von kundenspezifischen Schalenkernen für Anwendungen in der kontaktlosen Energie- und Datenübertragung. Kundenspezifische Schalenkerne Blinzinger ist der Spezialist für das Design und die Herstellung von Schalenkernen in kundenspezifischen Ausführungen die sich für vielfältige Anwendungen wie der kontaktlosen Daten/Energieübertragung (Drehübertrager) oder der Sensortechnik eignen. Die Kerne sind in individuellen Abmessungen und mit Öffnungen oder Nuten für Anschlussleitungen erhältlich, wobei Außendurchmesser von bis zu 200mm aus einem Stück realisierbar sind. Die Mittelachsen sind auch bei großen Bauhöhen präzise zentriert, wodurch sich die Kerne sehr gut für Drehgeber / Drehübertrager eignen.
Industrielle RJ45-Ethernet-Steckverbinder von TE Connectivity

Industrielle RJ45-Ethernet-Steckverbinder von TE Connectivity

RJ45 Industrial Connectors sind rechteckige Datenverbinder, die für Ethernet -Netzwerke in industriellen Anwendungen entwickelt wurden. Die Datenflussrate wird von 10/100 MB / s und 1 GB / s unterstützt. Ethernet-Magnete als Komponenten ermöglichen benutzerdefinierte Layouts von Ethernet-Ports, die für EMI und/oder Überspannung optimiert sind. Alle Ethernet-Magnetteile sind SMD und lötbar. Die vor Ort installierbaren Kabelstecker sind für Kabel mit 2 Paaren (10/100 Mbit/s) und 4 Paaren (1 G/10 Gbit/s) erhältlich, die Cat5e-, Cat6- und Cat6A-Leistung unterstützen. Die werkzeuglose Montage mit automatischem Drahtabschneiden sorgt für hochwertige Verbindungen und kurze Installationszeiten.
RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP

RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
E-DAT Industry Patchkabel RJ45

E-DAT Industry Patchkabel RJ45

‧ vollgeschirmtes Cat.6 Patchkabel AWG 26/7 S/FTP mit PUR-Mantel ‧ Beschaltung 1 - 1 ‧ Einhaltung der Klasse E nach ISO/IEC 11801, DIN EN 50173-1 ‧ Kabelfarbe gelb, Steckerfarbe grau ‧ Kabelfarben können abweichen ‧ bei Variante IP67 - IP67 folgende Längen verfügbar: 1, 2, 5, 10, 15 und 20 m ‧ bei Variante IP67 - RJ45 folgende Längen verfügbar: 1, 2, 3, 5, 10, 15 und 20 m ‧ bei Variante RJ45 - RJ45 folgende Längen verfügbar: 1, 2, 3, 5 und 7 m ‧ weitere Längen erhältlich
mehrphasiges Kabel mit konzentrischem Neutralleiter

mehrphasiges Kabel mit konzentrischem Neutralleiter

Dreiadriges Kabel mit einem konzentrischen Leiter, der als Neutralleiter vorgesehen ist. Mega Hertz = 1 Million Schwingungen pro Sekunde
CNC-Frästeile für die Elektronikindustrie

CNC-Frästeile für die Elektronikindustrie

Unsere CNC-Frästeile für die Elektronikindustrie werden mit höchster Präzision und Qualität gefertigt. Diese Teile sind ideal für den Einsatz in elektronischen Geräten und Komponenten, wo Genauigkeit und Zuverlässigkeit von größter Bedeutung sind. Wir nutzen modernste CNC-Technologie, um komplexe Bauteile herzustellen, die den spezifischen Anforderungen der Elektronikindustrie entsprechen. Unsere Frästeile tragen zur Leistungsfähigkeit und Langlebigkeit elektronischer Produkte bei und werden nach strengen Qualitätsvorgaben gefertigt und geprüft.
Industry Patchkabel RJ45 Cat.6A PUR

Industry Patchkabel RJ45 Cat.6A PUR

Geschirmte PUR-Leitung zur sicheren und industrietauglichen Datenübertragung in der Automatisierungs- und Feldbustechnik. Die Leitung erfüllt die Forderungen nach ULStyle 20963 und erfüllt die Vorgaben nach Cat7 (elektr. Eigenschaften in Anlehnung an EN50288-4-2). Die Materialien und der konstruktiver Aufbau ermöglichen erhöhte mechanische Beanspruchung (Abrieb, Biegung, Erschütterung etc.) der Leitung. Besondere Eigenschaften: UL-Style 20963, seewasserbeständig, recyclefähig, LABS-frei, RoHs-konform, säure- und laugenbeständig, UV-beständig, hydrolysefest, halogenfrei, ölbeständig, hohe Flexibilität, keine korrosiven Gase, mikrobenfest, keine Brandfortleitung. ‧ vollgeschirmtes RJ45 Patchkabel Cat.6A AWG 26/7 ‧ geeignet für 10 GBit Ethernet (IEEE 802.3an) ‧ Knickschutztülle gespritzt mit integriertem Rasthebelschutz ‧ Kabelmantel PUR ‧ Standardvarianten: 0,3 m, 1,0 m, 2,0 m, 5,0 m, 10,0 m. ‧ Andere Längen auf Anfrage
Revolution Pi Gate – Erweiterungsmodul zur Einbindung in ein industrielles Netzwerk

Revolution Pi Gate – Erweiterungsmodul zur Einbindung in ein industrielles Netzwerk

Problemlose Einbindung in ein bestehendes Modbus TCP Netzwerk Das RevPi Gate Modbus TCP dient dazu den RevPi Core problemlos in ein bestehendes Modbus TCP Netzwerk einzubinden. Das Modbus TCP Gateway wird über den obenliegenden Systemstecker mit dem Basismodul RevPi Core verbunden. Pro Basismodul können bis zu zwei unterschiedliche Gateways angebunden werden. Verfügbare Protokollvarianten: Modbus TCP Version: Slave Steckertyp: 2 x RJ45 Max. Baudrate: 10/100 Mbit/s I/O Daten: 480 Bytes IN/OUT Schutzklasse: IP20 Spannungsversorgung: 24 V DC (-15/+20%) EAN: 4260498390137
RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF

RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOUR, LSZH SHEATHEDRE-2X(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED,ARMOUR, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
BWU2828 | AS-i 3.0 PROFINET-Gateway mit integriertem Sicherheitsmonitor

BWU2828 | AS-i 3.0 PROFINET-Gateway mit integriertem Sicherheitsmonitor

Bis zu 32 Freigabekreise, Sichere Ausgänge werden unterstützt, 1 Sicherheitsmonitor für 2 AS-i Kreise, Applikationen bis Kategorie 4/PLe/SIL 3, Chipkarte zur Speicherung der Konfigurationsdaten.
Ultraschallschweißen / Ultraschallverdichten von Litzen und Kabel

Ultraschallschweißen / Ultraschallverdichten von Litzen und Kabel

Per Ultraschall kompaktierte Kupferleitungen verknüpfen ideal die Eigenschaften einer starren Leitung mit den Möglichkeiten flexiblen Kabelmaterials. (Ultraschallschweißen / Ultraschallverdichten) Verdichtet wird dabei per Ultraschall-Schweißen: Die Litzen bewegen sich bei geringem Druck und Schwingungen im Hochfrequenzbereich gegeneinander. So entsteht in Sekundenbruchteilen und ohne thermische Belastung der Bauteile eine dauerhafte, stabile und metallurgisch reine Verbindung. Diese verfügt über exzellente elektrische Eigenschaften. Die Vorteile des Ultraschallverdichtens liegen auf der Hand: Keine Übergangswiderstände, da keine Aderendhülsen Kleinere Abmessung bei gleichem Querschnitt Perfekt für kleine Anschlussräume Verdichtungslänge bis 20 mm Crimpform frei wählbar Verdichtungslänge: bis 20 mm
Typenreihe EN

Typenreihe EN

Kompaktnetzgerät nach EN 61558, Einphasen-Netzgerät Primärspannungen: von 110 bis 660V ± 5% umklemmbar Ausgangsspannung: 24 VDC nach DIN 19240 Restwelligkeit: kleiner 5% Temperaturbereich: -25° bis 50°C Lagerprogramm: 230 / 400 V ± 5% Optional: Sekundärsicherung max. 6,3 AT, bis EN 250 aufschnappbar
RJ45 Patchkabel Cat. 6 mit 1/1 Verdrahtung 8-polig gerade, Kabeltyp S/FTP 4x2xAWG27/7

RJ45 Patchkabel Cat. 6 mit 1/1 Verdrahtung 8-polig gerade, Kabeltyp S/FTP 4x2xAWG27/7

RJ45 Patchkabel Cat. 6 mit 1/1 Verdrahtung 8-polig gerade, Kabeltyp S/FTP 4x2xAWG27/7 Artikelnummer: 117892
BKDATA Ethernet Cat. 5e 1x4x26/7 AWG

BKDATA Ethernet Cat. 5e 1x4x26/7 AWG

Industrial Ethernet direkt vom Hersteller. Erhältlich als PVC-, PUR- und voll recyclebare ECO-Variante erhältlich. Standardaufmachungen ab Lager: 100 m-Ring, 500 m auf Spule und 1.000 m auf Spule. Anwendung / Produktmerkmale: Verkabelung nach EN 50173 EtherCAT® und Ethernet / IP Industrial Ethernet Kategorie 5e mit einer Übertragungsrate bis 100 MBit/s Erfüllt Echtzeitanforderungen für Industrie 4.0 Für flexiblen Einsatz und feste Verlegung geeignet Platzsparend durch kompakte Konstruktion mit Sternvierer-Verseilung Nachweis der Flammwidrigkeit durch hochwertige UL-Zulassungen: CMX-Listing Ermöglicht Patchkabel-Anwendungen bis max. 60 Meter Auch für Kurzlängen optimiert PROFINET® Adercodierung oder Ringmarkierung PVC: Öl- und UV-beständiges PUR: Öl-, mikroben-, hydorlyse-, und UV-beständig ECO: Außenmantel voll recycelbar Vom Standardprogramm abweichende Datenleitungen auf Anfrage.
Abschirmungen aus Wolfram und Wolframverbundwerkstoffen

Abschirmungen aus Wolfram und Wolframverbundwerkstoffen

Abschirmungen aus Wolfram, Molybdän und Legierungen für Röntgenröhren, Computertomographen, Detektoren, Linearbeschleuniger uvm. Abschirmungen aus Wolfram, Molybdän und Densimet® lassen Strahlung nur dort durch, wo sie gebraucht wird. Bei der Erzeugung von Röntgenstrahlung, rund um die Röntgenröhre und im Detektor garantieren unsere Werkstoffe eine minimale Strahlenbelastung der Umgebung. Flache Abschirmelemente produzieren wir mit einem innovativen, endkonturnahen Prozess. Das Ergebnis: Unsere Folien und Bleche haben eine besonders homogene Mikrostruktur und keine ausgeprägte Orientierung. Mögliche Produkte und Anwendungen sind: -Abschirmungskomponenten für die Röntgenröhre - Abschirmblenden für Computertomographen - Abschirmungen für Detektoren - Behälter für die Brachytherapie - Abschirmungen für Linearbeschleuniger - Abschirmungen für die Öl- und Gasförderung Artikelnummer: Shieldings Bestellmengen und Lieferkonditionen: 1
RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF

RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-PIMF,SINGLE & MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOUR, LSZH SHEATHEDRE-2X(St)HSWAH-PIMF,SINGLE & MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED,ARMOUR, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / blue ; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Blackk Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF

RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH-TIMF,MULTI-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / Beyaz / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
Energieübertragungssysteme, kontaktlose

Energieübertragungssysteme, kontaktlose

Kundenspezifische Schalenkerne für Drehübertrager von Blinzinger Elektronik. Kundenspezifische Schalenkerne Blinzinger ist der Spezialist für das Design und die Herstellung von Schalenkernen in kundenspezifischen Ausführungen die sich für vielfältige Anwendungen wie der kontaktlosen Daten/Energieübertragung (Drehübertrager) oder der Sensortechnik eignen. Die Kerne sind in individuellen Abmessungen und mit Öffnungen oder Nuten für Anschlussleitungen erhältlich, wobei Außendurchmesser von bis zu 200mm aus einem Stück realisierbar sind. Die Mittelachsen sind auch bei großen Bauhöhen präzise zentriert, wodurch sich die Kerne sehr gut für Drehgeber / Drehübertrager eignen.
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP

RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZH SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: According to BS 5308 Part 1 colour coded , Note: Other core configurations manufactured upon request Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
Patchkabel RJ45 6kV Flex500 Outdoor AWG 24

Patchkabel RJ45 6kV Flex500 Outdoor AWG 24

‧ RJ45 Patchkabel für Industrie und Außenanwendungen ‧ geschirmtes Cat.5e, Class EA RJ45 Patchkabel ‧ Einhaltung des Klasse EA Channel-Link nach ISO/IEC 11801-1, DIN EN 50173-1 ‧ getestet: Channel-Link bis 500 MHz ‧ für 10 GBit/s Ethernet (IEEE 802.3an) bis 40m geeignet ‧ besonders geeignet für ungeschirmte und geschirmte Class EA Systeme ‧ Robustes und abriebfestes Kabel für die Industrieanwendung, wie im Maschinen- und Anlagenbau. Ebenfalls geeignet für die Verlegung im Freien ‧ Einhaltung der VDE-AR-N 4100:2019-04 (6KV Stoßspannungsprüfung nach DIN EN 60664-1) bei Verlegung in Zählerplatz und Elektroverteilern ‧ Kabeltyp: S/UTP 4x2xAWG24/7 ‧ Kabelmantel LSHF (FRNC) PUR; schwarz ‧ Das Kabel ist für wiederholte bewegte Anwendung (Schleppkette) konstruiert. Getestet mit einem Biegeradius von 100mm und einer Beschleunigung von 4m/s² wurden 3 Mio. Zyklen bei Raumtemperatur erreicht. ‧ zwei geschirmte RJ45-Stecker, Beschaltung 1 - 1 ‧ UV; Öl beständig ‧ Remote Powering (PoE, PoE plus und UPoE) für IoT; M2M, IoT; HDBaseT; Industrie 4.0; Multimedia; Breitband-Video geeignet ‧ Knickschutztülle umspritzt ‧ deutlich längere Haltbarkeit als Standard-Patchkabel ‧ sehr kurze Knickschutztülle
Cat.7 Kabelverbinder IP67

Cat.7 Kabelverbinder IP67

‧ für die Verbindung/Verlängerung von Datenkabeln bis Cat.7A ‧ IP67 Schutz durch Spezialschrumpfschlauch ‧ in Verbindung mit Cat.6A bis Cat.8 Kabeln und Cat.6A Anschlusstechnik wird die Klasse EA nach ISO/IEC 11801 erfüllt ‧ Anschluss von Datenleitungen AWG26/1 - 22/1 (eindrahtig) ‧ Kabelzuführung von einer oder zwei Seiten möglich ‧ Cable sharing, Aufteilen von einem 8-adrigen auf zwei vieradrige Kabel möglich (ein Kabelverbinder an der Eingangs- und Ausgangsseite nötig) ‧ vollgeschirmtes Metallgehäuse ‧ Zugentlastung und davon getrennter 360º-Schirmanschluss, unverlierbar
Cat.7 Kabelverbinder

Cat.7 Kabelverbinder

‧ für die Verbindung/Verlängerung von Datenkabeln bis Cat.7A ‧ in Verbindung mit Cat.6A bis Cat.8 Kabeln und Cat.6A Anschlusstechnik wird die Klasse EA nach ISO/IEC 11801 erfüllt ‧ Anschluss von Datenleitungen AWG26/1 - 22/1 (eindrahtig) ‧ Kabelzuführung von einer oder zwei Seiten möglich ‧ Cable sharing, Aufteilen von einem 8-adrigen auf zwei vieradrige Kabel möglich (ein Kabelverbinder an der Eingangs- und Ausgangsseite nötig) ‧ vollgeschirmtes Metallgehäuse ‧ Zugentlastung und davon getrennter 360º-Schirmanschluss, unverlierbar ‧ 2 Bohrungen für Wandmontage ‧ IP67 Schutz durch Spezialschrumpfschlauch (130863-01-E)