200A-3PH MK3 Secondary Current Injection
200A-3PH MK3 Secondary Current Injection

200A-3PH MK3 Secondary Current Injection

Über dieses Produkt

WebsiteBesuchen Sie die Produktseite
0-50A three phase output Clear and simple user interface 3 phase current output 0-50A per phase output current True RMS digital metering Memory ammeter Multi-function timing system Auxiliary metering input Large back-lit liquid crystal display Thermal and over-current protection Compact and portable 220V or 400V 3 phase mains supply options 115V-440V 3 wire supply with optional supply transformer The 200A-3PH Mk3 Secondary Current Injection test system provides commissioning and maintenance engineers with a compact, portable and flexible system for the testing and timing of protective relays, circuit breakers and thermal overloads. The unit is equally at home testing solid state or electro-mechanical relays, and has a rating suitable for testing thermal trips. The 200A-3PH Mk3 has independent true RMS digital metering for each output, with independently selectable ranges. The outputs are isolated and independently variable, and allow the injection of currents up to 200A. The outputs are protected by electronic over-current trips and fuses. The timing system on the 200A-3PH Mk3 is flexible and exceptionally easy to use, allowing trip times to be measured to a high degree of accuracy. Units with auxiliary contacts may be timed using the NC or NO timer modes, and devices with no auxiliary contacts may be timed using the current operated mode. The unit is ideal for testing the following devices: Over and under current relays IDMT relays Thermal overloads Magnetic circuit breakers The units may also be used in conjunction with the DVS3 Digital Voltage Source to test protection systems requiring three voltages and three currents. Protection that may be tested in conjunction with the DVS3 includes: Directional relays Distance protection Power relays and transducers Main Output The units have three independently controlled outputs, one for each phase. The output is switched on and off by illuminated push buttons, and the current is set using the three control knobs on the front panel. All ranges are continuously variable from zero. Range Continuous 5 minutes 1 minute 0-5V 50A 100A 200A The above intermittent on-times must be followed by an off-time of 15 minutes, and are based on an ambient temperature of 25°C. Auxiliary AC Outputs A switched, isolated auxiliary 240V 50mA AC supply is available to power auxiliary control circuits. The output is protected by a fuse. Digital Metering The output on the 200A-3PH/ED is metered by a digital true RMS system with a 3.5 digit LED display. The range for each channel is independently selected for each channel by a switch on the front panel. Range Resolution Trip current Accuracy 20.00A 0.01A 21.0A ±0.6% rdg+5d 50.00A 0.01A 52.5A ±0.6% rdg+5d 100.00A 0.1A 105.0A ±0.6% rdg+5d 200.00A 0.1A 210.0A ±0.6% rdg+5d An electronic current trip is automatically set to 115% of full scale of the selected metering range to protect the device under test. The unit is must be supplied by a 400V±10% 50/60Hz 3 phase 3300VA Max. The optional delta-star supply transformer allows the 400V unit to operate from other supply voltages. A delta-star transformer is available as an optional accessory for operation from a 3 wire supply. Temperature Range: Storage -20°C to 60°C Operating 0°C to 45°C Timing System The timing system on the 200A-3PH mk3 is very flexible, allowing a wide range of protective devices to be timed. Range 0-999.999s Resolution 1ms Accuracy 0.01% rdg +1d (all except current operated mode) 0.01% rdg +3d (current operated mode) The contact circuit has an open circuit voltage of 24Vdc and a short circuit current of 20mA. The contacts may be connected to volt-free contacts or contacts connected to a DC voltage system (240Vdc maximum). The following functions are provided: Mode Timer Start Timer Stop Internal Start Press ‘ON’ Contact 1 Single Contact Contact 1 Contact 1 Dual contact Contact 1 Contact 2 Current operated Current > 20% of range Current < 20% of range The output is automatically switched off at the end of the test to safeguard the relay under test. Protection and Safety The 200A-3PH mk3 Secondary Current Injection is protected by electronic over current trips on the outputs, fuses on the contact input, the mains input and regulators. The auxiliary AC output is fuse protected on both units. An earth terminal is provided for connection to a local earth. WEIGHT 33 kg DIMENSIONS 315 × 550 × 300 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set 5m 200AL/3PH Output lead set OPTIONAL ACCESSORIES 200A-3PH delta-star transformer, Part no. A178-0001
Ähnliche Produkte
1/15
100A/E MK3 Secondary Current Injection Test Set
100A/E MK3 Secondary Current Injection Test Set
0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current lim...
DE-16562 Hohen Neuendorf/OT Bergfelde
PCU1-SP MK2 Primary Current Injection Test Set
PCU1-SP MK2 Primary Current Injection Test Set
5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switc...
DE-16562 Hohen Neuendorf/OT Bergfelde
PCU1-SP MK3 Primärstrom-Einspritztestsystem
PCU1-SP MK3 Primärstrom-Einspritztestsystem
Der PCU1-SP Mk3 ist ein vielseitiges Primärstrom-Injektionstestsystem, ideal für Stabilitäts- und Leistungsschaltertests, mit direkter Ablesung von Wa...
DE-16562 Hohen Neuendorf/OT Bergfelde
20A DC booster Winding resistance test
20A DC booster Winding resistance test
Maximum output current: 20 A DC Maximum power on output sockets: 400 W Current output switch: controlled by STCS Current output amplitude: controll...
DE-16562 Hohen Neuendorf/OT Bergfelde
100ADM MK5 Secondary Current Injection Test Set
100ADM MK5 Secondary Current Injection Test Set
0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current lim...
DE-16562 Hohen Neuendorf/OT Bergfelde
200ADM-P Secondary Current Injection Test Set
200ADM-P Secondary Current Injection Test Set
The 200ADM-P is a current injection system with a wide range of advanced features including phase shift, data storage and harmonic analysis. 0-200A...
DE-16562 Hohen Neuendorf/OT Bergfelde
5312.0 AC / DC Netzgerät unstabilisiert und Festspannung
5312.0 AC / DC Netzgerät unstabilisiert und Festspannung
Typ 5312.0 Kurzdaten AC / DC 0 – 25V / 10A; 6V / 5A Beschreibung AC / DC Netzgerät unstabilisiert und Festspannung Eingangsspannung 230VAC 50-60Hz ...
DE-16562 Hohen Neuendorf/OT Bergfelde
750ADM-H mk3 Current Injection System
750ADM-H mk3 Current Injection System
Primary injection up to 750A 4V output* 16V 40A output for secondary injection True RMS memory ammeter with single cycle capture Multi-function ti...
DE-16562 Hohen Neuendorf/OT Bergfelde
T 3000 Primary current injection test set
T 3000 Primary current injection test set
T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform di...
DE-16562 Hohen Neuendorf/OT Bergfelde
18kV 10mA DC Tester PT18-10 MK2
18kV 10mA DC Tester PT18-10 MK2
Ultra lightweight (6.9kg) 1-200Adc test current with <2.5% ripple Supplied with standard 3m output lead set 0.1μΩ resolution mV, A, and m/μΩ displ...
DE-16562 Hohen Neuendorf/OT Bergfelde
5311.3 Universalstromversorgung (5 Ausgänge) und Duchgangsprüfer
5311.3 Universalstromversorgung (5 Ausgänge) und Duchgangsprüfer
Typ 5311.3 Kurzdaten AC 230V / 2A;AC 0 – 250V / 3A;3bis24V / 2A;DC 5V/3A;DC 0 – 40V / 0 – 2,5A und Durchgangsprüfer mit Summer Beschreibung Universa...
DE-16562 Hohen Neuendorf/OT Bergfelde
2257.1 – Hochleistungsgleichspannungsregler
2257.1 – Hochleistungsgleichspannungsregler
Typ 2257.1 Kurzdaten 0 – 30V / 0 – 40A Beschreibung Hochleistungsgleichspannungsregler Eingangsspannung 230VAC 50Hz Trennung Eingang/Ausgang galva...
DE-16562 Hohen Neuendorf/OT Bergfelde
T 1000 PLUS Secondary injection relay test set
T 1000 PLUS Secondary injection relay test set
Multi-tasking test set designed for testing relays and transducers Max current output: 250 A Max AC voltage output: 250 V Max DC voltage output: 30...
DE-16562 Hohen Neuendorf/OT Bergfelde
eKAM Electronic primary injection test set
eKAM Electronic primary injection test set
eKAM is the new fully automatic electronic primary injection test equipment. e KAM test system includes two portable units: one control unit with a la...
DE-16562 Hohen Neuendorf/OT Bergfelde
2229.2 – Gleichspannungsregler
2229.2 – Gleichspannungsregler
Typ 2229.2 Kurzdaten 2x(0 – 40VDC / 0 – 2,5A)Digitalanzeigen Beschreibung Gleichspannungsregler Eingangsspannung 230VAC 50Hz Trennung Eingang/Ausg...
DE-16562 Hohen Neuendorf/OT Bergfelde

Die wer liefert was (wlw)-App ist da!

Nutzen Sie unsere verbesserte Anbietersuche oder erstellen Sie Ihre Anfragen jetzt auch mobil mit der neuen wlw-App für Einkäufer.

Jetzt im App Store herunterladen

App StoreGoogle Play